Installation and use 

SOLID CONTROL MCK 2200 

13 

Once the count is complete, the power supply to the solenoid valve is disconnected 
and the product output is blocked. 
Each time the solenoid valve is opened, the 2 bars at the top of the SV.DCHA display 
(ref. O3) will light up. These bars will remain on for as long as the opening status of the 
solenoid valve lasts. 

N.B. The solenoid valves are only activated if the keys ref. D, E, I are in the "START" 
configuration (LED off) 
The  GENERAL  START/STOP  key  (ref.  E)  has  priority  over  the  status  of  the  two 
sectionswhen the following is pressed: 

START/STOP GEN→ON      SECTIONS→ON; 
START/STOP GEN→OFF    SECTIONS→OFF. 

The  LEDs  of  the  three  keys  mentioned  above  follow  the  status  of  the  function 
associated with them. 
The two sections can work both in automatic mode, both in manual  mode or mixed. 
The  automatic  mode  can  be  enabled  on  the  two  sections  separately  with  the  two 
relative keys (ref. B and N). Entering the setting is indicated by the relative green LED 
going on. 
For the simultaneous switch of the two sections to automatic mode, the following key 
will be used (ref. E): “AUTO/MAN GENERAL”. 
The enabling of this setting is indicated by the relative green LED going on. This key 
(ref. E) has priority over the status of the two sections when the following is pressed: 
AUTO/MAN GEN→ON           SECTIONS→ON 
AUTO/MAN GEN→OFF         SECTIONS→OFF. 
The  LEDs  of  the  keys  mentioned  above  follow the  status  of  the  function  associated 
with them. 
 
The count of the total distributed litres and that of those left in the barrel is  based on 
the pulses coming from the flowmeter sensor, but is subject to the fact that at least one 
of the two sections is active; if both sections are not active, any pulses coming from 
the flowmeter will be ignored. 
 
 

4.9 

Manual mode 

You can proceed in two ways to switch from automatic to manual mode: 

1) 

– at any time, by pressing the "AUTO/MAN GENERAL" key (ref. E) on the 
computer, the green LED of the key goes off and the computer starts to work 
in manual mode with both sections. 

2) 

–  at  any  time,  by  pressing  one  of  the  two  "AUTO/MAN  -  SV.  IZQD"  or 
"AUTO/MAN  -  SV.  DCHA"  keys  (ref.  B  and  N)  on  the  computer,  the  green 
LED of the pressed key will go off and the relative solenoid valve will start to 
work in manual mode. 

Summary of Contents for MCK 2200

Page 1: ...DPA SOLID CONTROL MCK 2200 COMPUTER FOR SPRAYERS INSTRUCTIONS FOR USE NR ST2621 EN REV 3 EN...

Page 2: ...O ITALY Tel 39 0425 754713 Fax 39 0425 741130 E mail mcstaff mcelettronica it Internet www mcelettronica it Manual code ST2621 EN Issued July 2013 Edition October 2021 MC elettronica S r l is not obli...

Page 3: ...3 Working pressure ref O7 9 4 1 4 Distributed litres ref O8 9 4 1 5 Litres left ref O9 9 4 1 6 Sensor status ref O1 and O4 9 4 1 7 Solenoid valve status ref O2 and O3 10 4 1 8 Working hours 10 4 2 IZ...

Page 4: ...ted by the Customer before starting the mass production The electronic board of the MCK 2200 computer is treated with silicone resin to increase its resistance to possible infiltration of humidity or...

Page 5: ...SELECT RESET key for display indications and totalisers reset G General AUTO MAN key with green LED H PROG key for constants programming I Right START STOP key with red LED L key to decrease the valu...

Page 6: ...3C Status of the left sensor ON OFF IN PNP NO 2C Status of the right solenoid valve ON OFF OUT Vb 8A Status of the left solenoid valve ON OFF OUT Vb 8C Programming parameters Working hours General sol...

Page 7: ...en printed polyester B Self extinguishing ABS box closing black frame C Self extinguishing ABS grey container D Connector for signals and power supply E Fastening knobs F Self extinguishing ABS grey s...

Page 8: ...or receive new settings The function of the individual parts is explained below 4 1 Display The display can be show the following values 4 1 1 Number of partial plants REF O5 The partial plants are c...

Page 9: ...this To reset this value when it is shown on the display keep the SELECT key pressed until 0 appears on the display For the litres to be counted correctly the constant i must be set correctly see para...

Page 10: ...oid valves can be switched one at a time from the automatic operating status to the manual operating status Simply press one of the two special keys ref B and N and the solenoid valves will switch to...

Page 11: ...setting some constants described in the following paragraph N B Only in the case of the full opt art 4494 MCK 2200 model and during work out of the programming mode can an output be controlled by usin...

Page 12: ...crements of 1 can be reset by pressing the RESET key ref F for 3 SECONDS while the number of partial plants is shown on the display ref O5 4 7 3 Total plants totaliser 0 to 99999 increments of 1 canno...

Page 13: ...eous switch of the two sections to automatic mode the following key will be used ref E AUTO MAN GENERAL The enabling of this setting is indicated by the relative green LED going on This key ref E has...

Page 14: ...and that of the plants partial and total takes place in the same way as the automatic mode Even in this case the key ref G has priority over the status of the two sections when the following is press...

Page 15: ...15 CAUTION DO NOT WASH USING A POWER WASHER WITH PRESSURE JET WARNING THIS PRODUCT CONTAINS TIN AND LEAD IT MUST BE DISPOSED OF AT THE END OF ITS LIFE CYCLE AT THE DESIGNATED DISPOSAL FACILITIES OR DE...

Page 16: ...Printed in Italy Electronic equipment for agriculture www mcelettronica it...

Reviews: