Installation and use 

SEEDER MONITOR MCK 1200  

17

 

6.3 Automatic calibration of  “C” parameter  

The  automatic calibration of “C” parameter  is effected by covering  a fixed distance 
of 100 metres according to the instructions listed below: 
 

1. Measure a distance  of 100 metres on the ground and place the machine on 

the starting point;  

2. Display  ”C”  parameter;  press  “+”  (fig.  1,  ref.  A  )  and  “-“  (fig.1,  ref.  C)  keys 

simultaneously to start counting (the display will be reset) releas keys; 

3. Drive along a way of 100 metres and stop after covering that fixed distance; 

during  the  counting  phase  the  display  will  show  the  number  of  impulses 
received by the sensor;  

4. Stop  counting  by  pressing  “width  -  PROG.”  key  (rif.  B,  fig.1).  The  impulses 

obtained will be automatically programmed in  “C” parameter. 

 

6.4 How to programming the delay 

between visual and acoustic 

alarm

 

The programmable delay between the visual and the acoustic alarm is the time, in 
seconds,  that  runs  between  the  visual  signal  of  an  alarm  on  a  row  (the  relative 
segment  starts  flashing)  and  the  acoustic  alarm  signal;  this  delay  means  that  in 
case of temporary or brief alarm events on one or multiple rows, the operator is not 
continuously disturbed by the buzzer. 

With  the  monitor  switched  off,  press  keys  A,  B  and  C  together  and, while keeping 
them pressed, switch the monitor on by pressing the "ON/OFF" key and wait without 
releasing the keys. At the end of the initial test, 6 horizontal segments will appear on 
the  display  for  about  2  seconds,  then,  the  indication  "r  -"  followed  by  the 
programmed value: at this point, release the keys and press keys A or C individually 
to increase or decrease the programmed value. 

Once the desired  value has been  reached, keep key B pressed until the display re-
starts from the working hours indicating that the new data has been stored. 

Alarm delay “r” 

0 ÷ 5 seconds in steps of 

1 second 

default: 1 second 

 

6.5 How to programming the sensitivity of seeds to count 

To program the rows-alarm sensitivity (values from 1 to 20) the monitor must be off. 
Press  B  and  C  keys  (ref.  Fig.  1  pag.Errore.  Il  segnalibro  non  è  definito.
simultaneously  and  hold  them  pressed;  at  the  same  tome  power  on  the  monitor, 
and  keep  on holding  B and C keys pressed until „S-“ text  is  displayed, followed  by 
the current sensitivity  value; press C(-) or A(+) keys to  change the displayed value 
(ref. Fig.  1  pag.Errore. Il segnalibro non è definito.), while press and hold A key 

Summary of Contents for MCK 1200

Page 1: ...MCK 1200 COMPUTER FOR PRECISION SEED DRILLS USER S MANUAL NR 2839 EN REV 1 EN...

Page 2: ...IGO ITALY Tel 39 0425 754713 Fax 39 0425 741130 E mail mcstaff mcelettronica it Internet www mcelettronica it Manual code 2839 EN Issued February 2012 Edition November 2014 MC elettronica S r l is not...

Page 3: ...e C parameter to be programmed 16 6 3 Automatic calibration of C parameter 17 6 4 How to programming the delay between visual and acoustic alarm 17 6 5 How to programming the sensitivity of seeds to c...

Page 4: ...use of the equipment After buying the instrument read the manual carefully and refer to it any time you have doubts on how to use the equipment or when you have to carry out maintenance operations Ke...

Page 5: ...properly act of God lightning floods fire or other causes which do not depend from MC elettronica Repairs under guarantee which must be carried out in the laboratories of our authorized centres are e...

Page 6: ...he operation of the file indicating the LCD by horizontal bars any abnormality of sowing During the working cycle the following data are displayed and controlled the width width PROG the working area...

Page 7: ...and the photocells Insert the connector of the photocell fitted on the 1st element of the seed drill onto the connector of cable 1 N B The first element of the seed drill can be considered the one on...

Page 8: ...mechanic movement in the wheel front or rear wheel of the agricultural vehicle machine or by making a metal reference which sticks out of at least 7 mm Figure 2 ref C We recommend to install the speed...

Page 9: ...pplication of a six row wiring cod CAB SEM 002 by selecting the first row of the left of the planter fix the junction box A at the centre of the seed drill with some clamps held to the machine For ins...

Page 10: ...stallation on the pipe cod 10FOT SEMIMINUTI 0001 Figure 5 Example of installation on the sowing element cod 4228 and cod 10FOT SEMIMINUTI 0001 Optical elements Clamps Amplifier for photocell Electric...

Page 11: ...the programming phase it increases the displayed value B WIDTH PROG key it allows the operator to display and change the working width C ha TOTAL e key it shows the total area worked in hectares range...

Page 12: ...80 cm CAB SEM 002 Cable 6 rows x 80 cm CAB SEM 003 Cable 8 rows x 80 cm CAB SEM 004 Cable 12 rows x 80 cm NOTE cables must be ordered according to the type of seed drill used the following data are r...

Page 13: ...hold down any key for about 3 seconds while the display visualizes working hours after the initial test operated at the switching on After working hours the monitor displays the rows which are operati...

Page 14: ...y Keeping width PROG key pressed hold down also key rif A fig 1 to increase or key rif C fig 1 to decrease the displayed value until the desired value is obtained expressed in metres and centimetres f...

Page 15: ...the current parameter value preceded by letter C flashing then release keys Press key ref A fig 1 to increase or key ref C fig 1 to decrease the displayed value until the desired value from 20 to 999...

Page 16: ...for our example let s say 30 then stop the machine end point Figure 5 ref B to obtain highest precision of setting you ll need to go at least 50 meters 3 measure the distance from the starting point t...

Page 17: ...brief alarm events on one or multiple rows the operator is not continuously disturbed by the buzzer With the monitor switched off press keys A B and C together and while keeping them pressed switch t...

Page 18: ...hich the visual alarm is triggered followed by the acoustic one The same time applies for the resetting of the alarm the programmable values range from 21 to 28 and correspond to the following times 2...

Page 19: ...owing Turn on the Monitor button ON OFF and wait until the display shows the 0 0 Simulated test With one of your fingers or with a small object pass in front of each photocell if the photocell is corr...

Page 20: ...ment Clean the instrument with a wet cloth and mild detergent to avoid erasing the serigraphs on the panel Warning Do not use pressure water jets Do not use abrasive products solvents or alcohol Do no...

Page 21: ...Weather conditions Relative humidity 90 Transport and storage Temperature 25 C 85 C 8 2 Technical data accessories 8 2 1 Speed sensor D 18 cod 481 Power supply voltage 8 VDC Output signal NAMUR Max w...

Page 22: ...tection degree IP 68 8 2 4 Cables cod CAB SEM 001 CAB SEM 002 CAB SEM 003 CAB SEM 004 Main connector SICMA 24 way Connectors for photocells AMP 3 way Super seal IP 67 Cables for connecting photocells...

Page 23: ...Installation and use SEEDER MONITOR MCK 1200 NOTE...

Page 24: ...Printed in Italy SEEDER MONITOR MCK 1200 www mcelettronica it Electronic equipments for agricultural earth moving industrial machines...

Reviews: