STOVE DESCRIPTION 

 
Solid fuel stove for central heating 

THERMO VULKAN 

is produced and tested 

according to the European standard EN 13240. On figure no. 1 given in the 
introduction page, layout of the stove with integral parts important for handling is 
displayed.  Floor oven Thermo Vulkan has boiler of 24 liters capacity which is made 
of boiler sheets with standard thickness. With production like this, life span of the 
boiler increases. Water connections are 1“.Working area is consisted of cast plate 
(fig. 1, pos. 5) with smoke exhaust connection (fig. 1, pos. 7) which is mounted on 
the plate with two screws. Firebox area is built with bricks made of vermiculite. 
Firebox door (fig.1, pos.8) are made of cast iron and has transparent glass. Ashtray 
door (fig.1, pos.11) are made of cast iron and has manual air flow regulator. 

   

 

Fig. 1. Integral parts of Thermo Vulkan 
1 – natural stone 
2 – secondary air flow regulator  
3 – boiler  
4 – cast iron grid 
5 – thermo-regulator button 
6 – ashtray  
7 – smoke exhaust 
8 – firebox door 
9 – firebox door handle 
10 – auxiliary air regulator  
11 – ashtray door 
12 – ashtray door handle 
 
Central heating stoves are intended for heating of residential facilities. Integral part of 
installation is thermal valve which serves as safety thermal valve against eventual 
overheating. Recommended safety thermal valve is 

Caleffi 544 ½,

 displayed in fig.2. 

 

Comment:

 Thermal valve is not a part of the product and will not be delivered with it.     

Guarantee for central heating stove is valid excusively with thermal valve installed. 

Summary of Contents for THERMO VULKAN

Page 1: ...MANUAL INSTRUCTION Solid fuel stove for central heating THERMO VULKAN...

Page 2: ...hnical characteristics which place it into top class and you will be assured of it during exploitation Please carefully read this manual before you start to use his oven since you will find tips and t...

Page 3: ...use 1 Description 2 Installation 4 Installation to the water heating system 6 Managing operation of the stove 10 Firing up and ignition 11 Cleaning and maintenance 12 General notes 13 Advices for envi...

Page 4: ...e and play in vicinity of the stove Only spare parts approved by the manufacturer may be installed on the stove Do not make any changes to the stove At the first firing up slight smoking may occur esp...

Page 5: ...e Firebox door fig 1 pos 8 are made of cast iron and has transparent glass Ashtray door fig 1 pos 11 are made of cast iron and has manual air flow regulator Fig 1 Integral parts of Thermo Vulkan 1 nat...

Page 6: ...00 x 400 mm Weight wihtout water with water 156 177 kg Minimal distance from combustible materials back 50 cm side 50 cm front 80 cm Emission of CO reduced to 13 O2 wood 0 07 0 966 g m coal 0 08 1 003...

Page 7: ...ted too deeply into the chimney not to reduce surface of its cross section thus reducing draft Ventilators which work in the same room in which stove is mounted may create disturbances with the stove...

Page 8: ...chimney may be fig 3 1 Chimney is lower then top of the roof small cross section of the exit 2 Too large slope 3 Abrupt alteration of the direction of smoke channel 4 Oven or other device connected t...

Page 9: ...d must be set to the pressure of max 3 bar boiler is tested for 4 bars Connection guide of safe valve must be as shorter as possible and may not have capability of closing In this guide also may not b...

Page 10: ...expansion vessel short connection between safety distribution guide and safety return guide is to be installed which on winter provides freezing of water in expansion vessel On safety distribution and...

Page 11: ...entative or vendor Important All connections must be well sealed and tightened Prior to operation complete installation should be tested with water under pressure of 2 5bar At the mounting of safety v...

Page 12: ...sity of the burning should be regulated on the air flow regulator fig 1 pos 3 close burner and ashtray door after creation of basic cinder put into the firebox some bigger pieces of woods or coal and...

Page 13: ...tion of the stove and may cause damages and pollution of environment Increased external temperatures may cause weak draft in the chimney thus it is recommended more frequent burning in smaller quantit...

Page 14: ...ake following steps Immediately call fire department Suppress oxygen inflow into the chimney and turn off the stove Do not put anything in chimney and look after fire not to extend to the wooden const...

Page 15: ...enable proper operation and longer life span of the stove Cleaning of external surfaces with soft cloth which will not damage stove surfaces Chemical cleaning agents may be used and don t damage surf...

Page 16: ...er of the stove will lose the right to service guaranteed by the manufacturer Procurement of spare parts is to be done exclusively through manufacturer based on positions and figures or their names in...

Page 17: ...removal and disposing of wooden battens since they are nailed Product Device is made of materials which may be recycled At the disposal of waste Observe local environmental laws Use only recommended...

Reviews: