Technical data 

 

FASK: Used material 

 
Model 

FASK 100, 150, 200 and 300 

Coil & connection cable Thermoplastic rubber flame retardant according to UL 94 V-0 
Fastener 

acc. PA6 UL 94 V-0 

Colour (Coil) 

orange 

Shielding 

100% coil and 100% electric wire 

 

FASK: Safety 

 
Model 

FASK 100, 150, 200 and 300 

Certifications 

 CE certified (This product satisfies the provisions of the low voltage directive 2014/35/EU 

 

This product satisfies the provisions of RoHS 2.0 directive 2011/65/EU 

 

Protection degree: IP 68 

Insulation voltage 

coil: 3000V 

 

electric wire: 1000V 

Measurement cat. 

1000V CATIII; 600V CATIV 

 

FASK: Technical data 

 

Model 

FASK-100 

FASK-150 

FASK-200 

FASK-300 

Coil length 

395 mm 

525 mm 

665 mm 

965 mm 

Window size 

100 mm 

150 mm 

200 mm 

300 mm 

Reference rated current 

1,000 A 

3,000 A 

6,000 A 

10,000 A 

Weight 

app. 100-160 g 

Output signal 

100 mV/kA @ 50 Hz 

Transformation errors 

< 0.5 % (central position near the fastener @ 25 °C) 

Phase error 

≤ 0.5 ° (30 arc minutes) 

Maximum current measurable 

100 kA 

Coil resistance 

between 100 and 250 Ohm 

Coil diameter (orange cable) 

8 mm 

Connection cable length 

3 m / 5 m 

3 m 

3 m 

3 m 

Temperature coefficient 

400 ppm/K 

Position error 

± 1 % maximum 

Linearity error 

± 0.2 % maximum of the measured value 

Bandwidth 

1 Hz up to 100 kHz (- 3dB) 

Ambient temperature 

-30 up to +80 °C 

Storage temperature 

-40 up to +90 °C 

 

 

Summary of Contents for FASK-100

Page 1: ...ls FASK and the associated measurement transducer ROI 3 Read these operating instructions carefully before installing the product MBS AG Eisbachstr 51 Germany 74429 Sulzbach Laufen Technical support 4...

Page 2: ...ns and indicates an electrical hazard This symbol is an addition to the safety instructions and indicates a po tential hazard This symbol with the word Note describes Procedures that do not pose any r...

Page 3: ...national safety regulations as well as standard engineering practice Observe the installation instructions provided De energise the system before starting the work Check that it is de energised De en...

Page 4: ...ic wire 1000V Measurement cat 1000V CATIII 600V CATIV FASK Technical data Model FASK 100 FASK 150 FASK 200 FASK 300 Coil length 395 mm 525 mm 665 mm 965 mm Window size 100 mm 150 mm 200 mm 300 mm Refe...

Page 5: ...riptions FASK 100 FASK 150 FASK 200 FASK 300 A Window size A mm 135 165 210 310 B Window size B mm 100 150 200 300 C Outside diameter coil mm 151 181 226 326 D Coil diameter mm 8 E Connection cable le...

Page 6: ...rement value 10 120 of rated current Frequency bandwidth 30 Hz up to 5 kHz Maximum burden per phase 0 5 Energy consumption 10 W Output 0A zero drift 0 01A Temperature coefficient 200 ppm K Weight 185...

Page 7: ...g coil audibly latches Make sure that the measuring coil does not touch the power rail that is to be measured or a neighbouring rail because the maximum permissible temperature of the signal line is 8...

Page 8: ...lity or guarantee is assumed for this choice The information in the catalogs and data sheets does not represent any assurance of special properties but results from empirical values and measurements L...

Page 9: ...ent transformer inputs The 1 A outputs of the ROI 3 must not be earthed Likewise the input terminals of the measuring device must not be earthed energy meter I1 I2 I3 S1 S2 S1 S2 S1 S2 current measure...

Reviews: