ALARM SIGNALS
9.
THE PRESENT MANUAL IS PROPERTY OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.
9.1
List of alarms
Anomalies are shown on Display 2 during operation, see the description:
P1NO - Chamber probe alarm
: temperature probe broken or cut off.
P7NO - Board temperature alarm
: board overheated (over 70° C).
MOT - Motor alarm
: motor overheated.
EEP
: incorrect software load/update.
FLAM
: no flame.
VENT - Vent alarm
: venting device malfunction.
OFF RUN alarm
: fan device malfunction.
Press "PLUS" (Fig 2/D) for 5 seconds to temporarily shut off the alarm. The
message will reoccur until resolution of the problem.
Contact the authorised service centre.
The authorised technician will identify the cause of the problem
and restore proper operation.
TROUBLESHOOTING
Whenever the appliance does not work properly, try to solve the less serious problems using
this table.
ANOMALY
POSSIBLE CAUSE
INTERVENTION
The appliance does not turn on.
•
The master switch is not con-
nected.
•
The circuit breaker or magnetic
circuit breaker has tripped
•
Connect the master switch.
•
Reset the circuit breaker or ma-
gnetic circuit breaker
The inner walls are covered with
limescale.
The water softener is not con-
nected or is empty
•
Connect the appliance to a wa-
ter softener.
•
Regenerate the water softener.
•
Descale the cooking com-
partment.
The cooking compartment is
stained.
•
Quality of the water.
•
Ineffective detergent.
•
Insufficient rinsing.
•
Filter the water (see water sof-
tener).
•
Use the recommended detergent.
•
Rinse once again.
The gas appliance will not turn on
•
Gas valve closed.
•
Air in the hose
•
Open the gas valve
•
Repeat the operation
No water
The water tap is closed
Open the water tap
Electronic components overheating
(Alarm board temperature)
Cooling fans obstructed
Free the air passage or clean the
filters
"Filter Cleaning" Message
Filter maintenance timer expired
Proceed with cleaning (see 8.4
Periodic inspections to perform)
If the problem cannot be resolved, turn the appliance off and shut all the supply valves. Then