TRAFx MANUAL: PART II
Mountain Bike Counter
2018
www.trafx.net
4
C
SETTINGS
The counter has default settings (see black area below). Normally, only change these if a star below applies to you.
(The default settings are for G4 counters; however, they are also recommended for G2 and G3 counters.)
Settings
Mode
Notes
=TIME
=START
MB
--
--
TIME
- automatically set by a dock in Shuttle Mode.
START
- automatically set by a dock in Shuttle Mode to:
•
top of the hour after
Launch
for hourly totals
•
5 minutes after
Launch
for timestamps
PERIOD
DELAY
THRESHOLD
001
008
008
MODE SETTINGS
PERIOD
(1/24/0)
PERIOD
refers to the data format: hourly totals, daily totals, or timestamps (all are records)
▪
14 000 is the maximum number of records (lines of data)
▪
Totals are much more memory efficient and download much faster than timestamps
001
= Hourly totals (default; recommended); stores 19 months of data (448 million counts max.)
024
= Daily totals (rarely used); whole days only; counting starts and stops at mid-night
000
= Timestamps (seldom used); each event creates a timestamp (14 000 counts max.)
yy-mm-dd,hr:mm,total
16-05-28,10:00,00435
Hourly totals
16-05-28,11:00,00473
(11 spans 11 to 12)
16-05-28,12:00,00530
16-05-28,13:00,00481
yy-mm-dd,hr:mm:ss,diagnostic value
16-05-28,14:15:50,18
16-05-28,14:15:56,42
Timestamps
16-05-28,14:19:08,19
16-05-28,14:19:22,31
DELAY
DELAY
refers to “delay after event”
▪
During
DELAY
, other events (triggers) are ignored
▪
DELAY
values (and seconds) are shown below
DELAY
Seconds
A count occurs in the detection zone. The
DELAY
prevents counting the same bike
again, while it is still in the zone.
000
004
008
=
016
032
048
064
0
0.25
0.5
1
2
3
4
▪
If bikes typically move slowly, increase
DELAY
to
016
▪
If bikes typically are closely spaced, decrease
DELAY
to
004
THRESHOLD
THRESHOLD
adjusts
the counter’s sensitivity
008
is the default (and recommended)
THRESHOLD
value
▪
Use
THRESHOLD
006
(G4 counters only) if you are missing bikes. 006 is maximum sensitivity
▪
The other way to increase sensitivity is simply to move the counter closer to where bikes pass
▪
A
THRESHOLD
value greater than 012 is not recommended
Change settings
Here are the main steps to change settings:
1. Confirm your dock is in PC Mode
2. Connect: PC---cable(s)---dock---counter
3. Open TRAFx Communicator and click GO!
4. Enter C to confi
gure a mode’s settings
See TRAFx Manual Part I, p. 10 for details. Download at
www.trafx.net/support
Counters yield estimates. They are rarely 100% accurate. This applies to all types and brands. Counter
calibration is recommended when higher accuracy is desired. Calibration involves comparing counter
totals with those observed by a person, ideally over several hours. It is also a good opportunity to collect
additional data (youth vs. adult, etc.). Fo
r detailed instructions, download “How to calibrate a counter” at
www.trafx.net/support