background image

 

 

INTRODUCTION 

This manual contains installation, operation and maintenance instructions which, if followed correctly, will ensure 

the safe and efficient operation of the Fire Door. It is therefore essential that the manual is read thoroughly in 

advance of use to ensure you get the best out of your Fire Door and that you are operating it in a correct and safe 

manner. The Fire Door is designed to be fitted as a component of a complete fireplace. It is important that the 

complete fireplace is installed correctly before the Fire Door component is added.  

Mazona

 Stoves will not be 

responsible for any consequential or incidental loss or injury however caused.  

TESTING 

This component has been tested by an independent laboratory (SGS) to a European standard closest to the intended 

use (EN13229) with an open fireplace. When burning beech wood the fireplace and Fire Door produced 5kW of heat 

at an average efficiency of 69%. CO output at 13% O2 was recorded at 0.17%. 

WARNING 

Fitting the Fire Door to an existing open fireplace will increase the temperature in the “firebox” or “burning 

chamber”. A competent person must check to ensure that the existing firebox and chimney can withstand the 

increase in temperature. The firebox and chimney should be heat resistant to a continuous temperature of 450°C. 

UNPACKING 

The Fire Door is heavy and assistance will be required during the unpacking and installation. Remove the outer 

carton and inner plastic cover from the appliance. Care should be taken in removing the outer cardboard box as 

exposed staples may cause injury. 

BEFORE INSTALLATION 

For practical guidance in respect to the installation of your Fire Door, required ventilation, hearth construction, flue 

construction and compliance with building regulations please refer to: 

 Approved Document J of the Building regulations 2000 (England and Wales) 

http://www.planningportal.gov.uk/buildingregulations/approveddocuments/partj/approved 

The Communities and Local Government website: 

www.communities.gov.uk

 

The Planning Portal website: 

www.planningportal.gov.uk

 

If you are the person undertaking the building work you can seek assistance from the relevant local authority 

building control service or from your approved inspector.  

Please note that, depending on which part of the UK or Ireland the stove is being fitted, you may be responsible for 

ensuring that the work carried out complies with building regulations. The building owner may also have a 

responsibility for ensuring compliance of building regulation requirements. 

 

Summary of Contents for Fire Door

Page 1: ...amiliarise themselves with the operation and maintenance sections of the manual in advance of using the Fire Door Incorrect installation of the Fire Door can be dangerous The installation should be ca...

Page 2: ...Distance From Combustibles Fitting OPERATION Warning Controlling the Fire Door Fire Guard Recommended Fuels Fuel to avoid Weather Conditions 3 3 3 3 3 4 4 4 4 5 5 5 8 8 9 9 9 9 10 MAINTENANCE Baffle...

Page 3: ...chimney can withstand the increase in temperature The firebox and chimney should be heat resistant to a continuous temperature of 450 C UNPACKING The Fire Door is heavy and assistance will be required...

Page 4: ...e in a building which can cause spillage of combustion products from an open flued appliance This can occur even if the appliance and the fan are in different rooms If mechanical extraction is unavoid...

Page 5: ...limit the risk of people being accidently burnt The hearth should be able to support the weight of the stove and its chimney if the chimney is not independently supported SAFE DISTANCE FROM COMBUSTIBL...

Page 6: ...ect the 8mm threaded bar to the holes in the top of the frame Slide the head brackets over the threaded bar and tighten with the 8mm nuts provided Excess threaded bar should be trimmed to allow for sw...

Page 7: ...hers provided Fix the base of the door to the fireplace hearth using the 2 screw holes in the bottom of the frame After fixing the base of the frame to the hearth tension the nuts on the lintel bracke...

Page 8: ...y a professional person for any sign of blockage Do not attempt to relight the appliance until the source of the blockage has been determined and cleared Seek professional opinion on the cause of the...

Page 9: ...letely dry and free from preservatives may be used Anthracite Medium smokeless fuel Peat properly dried with low moisture content Eco Logs Briquettes Guidance on the correct fuels to use in your fire...

Page 10: ...m you retailer is recommended for stubborn stains Door Check that the seal around the door is air tight Replace rope seal if necessary Paintwork If paintwork needs repair contact your retailer directl...