background image

 

 

Video Door Phone

·

User Manual

 

12 

 

5

 

Local Operation 

5.1

 

Door Station Local Operation 

 

Figure 5-1

 

Call Button of Door Station 

Steps: 

Press the call button to call the 
resident. 

NOTE

 

When press the call button to 
call the resident, the maximum 
ring duration of the indoor 
station is 30s. 

5.2

 

Indoor Station Local Operation 

Table 5-1

 

Indoor Station Local Operation Description 

Keys 

Description 

 

Accept or decline the incoming call. 

 

Unlock the door.   

 

Open or close the live view. 

 

Switch the live view among the first door station, the second door station, 
and the analog camera.   

 

Counterclockwise rotation 

Increase the volume. 

Clockwise rotation 

Decrease the volume. 

NOTE

 

 

The maximum live view duration is 60s; and the maximum speaking duration is 60s.   

 

During the ring duration, speaking duration, or live view duration, the resident can 

unlock the door. The unlocking status can maintain 5 seconds after pressing the 
Unlock key.   

 

To achieve the optimal pickup effect, the recommended distance range between the 

speaker and the microphone of the indoor station or the door station is 30 to 40 cm. 

Summary of Contents for PM07-800L

Page 1: ...Video Door Phone Door Station and Indoor Station User Manual...

Page 2: ...SPECTION OR OTHER INTERNET SECURITY RISKS HOWEVER OUR COMPANY WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED SURVEILLANCE LAWS VARY BY JURISDICTION PLEASE CHECK ALL RELEVANT LAWS IN YOUR JURISDICTI...

Page 3: ...ul interference 2 This device must accept any interference received including interference that may cause undesired operation EU Conformity Statement This product and if applicable the supplied access...

Page 4: ...d on wall or ceiling the device shall be firmly fixed If smoke odors or noise rise from the device turn off the power at once and unplug the power cable and then please contact the service center If t...

Page 5: ...rwise the equipment damage may occur Please wire the power cable according to the instruction as wrong wiring may cause equipment damage Do not allow the child to push the device from the bottom just...

Page 6: ...Station 3 3 1 2 Terminals of Door Station 3 3 2 Wiring Description 4 3 2 1 Wiring 1 1 Door Station and 1 Indoor Station 6 3 2 2 Wiring 2 1 Door Station and 3 Indoor Stations 7 3 2 3 Wiring 3 2 Door S...

Page 7: ...intercom communication Supports two door stations simultaneously in the intercom system Supports monitoring the door station and the external analog camera Remote unlocking Convenient installation an...

Page 8: ...pply Indicator 2 Call Accept Decline Key 3 Unlock Key 4 Live View Key 5 Switch Key 6 LCD Screen 7 Microphone 8 Terminals and Interfaces 9 Loudspeaker 10 Volume Control Knob 2 2 Door Station Figure 2 2...

Page 9: ...ndoor Station Table 3 1 Descriptions of Terminals Indoor Station Name No Interface Description Camera 1 CAM Analog Camera Access Power Supply 2 12 VDC 12 VDC Power Supply Input Four Wire Interface A1...

Page 10: ...Lock Relay Output Common F3 Yellow NC Door Lock Relay Output Normally Closed 3 2 Wiring Description Purpose The four wire indoor station and the four wire door station are 2 basic but major component...

Page 11: ...m RVV4 0 75 mm 2 50 m TD 100 m RVV4 1 5 mm 2 On the rear panel of the indoor station four wire interface A and four wire interface C compose a cascading group and four wire interface B and four wire...

Page 12: ...sulated tape to tape the bare wires so as to avoid the short circuit Indoor Station Analog Camera Electric Bolt Door Station Red NO Blue COM Yellow NC Red Wire for power supply Blue Wire for video out...

Page 13: ...so as to avoid the short circuit Indoor Station 1 B Wire for power supply V Wire for video input A Wire for audio input G Wire for grounding Analog Camera 1 Indoor Station 2 Analog Camera 2 Indoor St...

Page 14: ...rcuit Indoor Station 1 Analog Camera 1 Indoor Station 2 Analog Camera 2 B Wire for power supply V Wire for video input A Wire for audio input G Wire for grounding Indoor Station 3 Analog Camera 3 Door...

Page 15: ...he junction box and the wall mounting without the junction box For the wall mounting with junction box the wall mounting plate and the junction box are required And for the wall mounting without junct...

Page 16: ...the rear panel of the indoor station during which the lock catch will be locked automatically Hooks Slot Slot Lock Catch Figure 4 3 Hooking the Indoor Station to the Plate NOTE For the installation wi...

Page 17: ...Fix the wall mounting plate to the wall with 2 screws 2 Hook the door station to the shield tightly by inserting the hooks of shield panel into the slots on the rear panel of the door station 3 Secur...

Page 18: ...oor Open or close the live view Switch the live view among the first door station the second door station and the analog camera Counterclockwise rotation Increase the volume Clockwise rotation Decreas...

Page 19: ...e installing the indoor station make sure that the distance between any two devices is far enough to avoid the howling and echo The distance between two devices is recommended to be longer than 10 met...

Reviews: