2.

 

Fix the wall mounting plate to the junction box with 2 screws. 

Screws

Wall Mounting Plate

Junction

 Box

 

Figure 4-2

 

Installing the Plate 

3.

 

Hook the indoor station to the wall mounting plate tightly by inserting the plate hooks 

into the slots on the rear panel of the indoor station, during which the lock catch will 
be locked automatically.   

Hooks

Slot

Slot

Lock Catch

 

Figure 4-3

 

Hooking the Indoor Station to the Plate 

NOTE

 

For the installation without the junction box, you should fix the wall mounting plate to 
the wall with 2 expansion screws first, and then hook the indoor station.   

4.2

 

Door Station Installation 

Accessoris (Door Station) 

To  install  the  door  station,  the  wall  mounting  shield  and  the  wall  mounting  plate  are 

Summary of Contents for PM07-800L

Page 1: ...Video Door Phone Door Station and Indoor Station User Manual...

Page 2: ...SPECTION OR OTHER INTERNET SECURITY RISKS HOWEVER OUR COMPANY WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED SURVEILLANCE LAWS VARY BY JURISDICTION PLEASE CHECK ALL RELEVANT LAWS IN YOUR JURISDICTI...

Page 3: ...ul interference 2 This device must accept any interference received including interference that may cause undesired operation EU Conformity Statement This product and if applicable the supplied access...

Page 4: ...d on wall or ceiling the device shall be firmly fixed If smoke odors or noise rise from the device turn off the power at once and unplug the power cable and then please contact the service center If t...

Page 5: ...rwise the equipment damage may occur Please wire the power cable according to the instruction as wrong wiring may cause equipment damage Do not allow the child to push the device from the bottom just...

Page 6: ...Station 3 3 1 2 Terminals of Door Station 3 3 2 Wiring Description 4 3 2 1 Wiring 1 1 Door Station and 1 Indoor Station 6 3 2 2 Wiring 2 1 Door Station and 3 Indoor Stations 7 3 2 3 Wiring 3 2 Door S...

Page 7: ...intercom communication Supports two door stations simultaneously in the intercom system Supports monitoring the door station and the external analog camera Remote unlocking Convenient installation an...

Page 8: ...pply Indicator 2 Call Accept Decline Key 3 Unlock Key 4 Live View Key 5 Switch Key 6 LCD Screen 7 Microphone 8 Terminals and Interfaces 9 Loudspeaker 10 Volume Control Knob 2 2 Door Station Figure 2 2...

Page 9: ...ndoor Station Table 3 1 Descriptions of Terminals Indoor Station Name No Interface Description Camera 1 CAM Analog Camera Access Power Supply 2 12 VDC 12 VDC Power Supply Input Four Wire Interface A1...

Page 10: ...Lock Relay Output Common F3 Yellow NC Door Lock Relay Output Normally Closed 3 2 Wiring Description Purpose The four wire indoor station and the four wire door station are 2 basic but major component...

Page 11: ...m RVV4 0 75 mm 2 50 m TD 100 m RVV4 1 5 mm 2 On the rear panel of the indoor station four wire interface A and four wire interface C compose a cascading group and four wire interface B and four wire...

Page 12: ...sulated tape to tape the bare wires so as to avoid the short circuit Indoor Station Analog Camera Electric Bolt Door Station Red NO Blue COM Yellow NC Red Wire for power supply Blue Wire for video out...

Page 13: ...so as to avoid the short circuit Indoor Station 1 B Wire for power supply V Wire for video input A Wire for audio input G Wire for grounding Analog Camera 1 Indoor Station 2 Analog Camera 2 Indoor St...

Page 14: ...rcuit Indoor Station 1 Analog Camera 1 Indoor Station 2 Analog Camera 2 B Wire for power supply V Wire for video input A Wire for audio input G Wire for grounding Indoor Station 3 Analog Camera 3 Door...

Page 15: ...he junction box and the wall mounting without the junction box For the wall mounting with junction box the wall mounting plate and the junction box are required And for the wall mounting without junct...

Page 16: ...the rear panel of the indoor station during which the lock catch will be locked automatically Hooks Slot Slot Lock Catch Figure 4 3 Hooking the Indoor Station to the Plate NOTE For the installation wi...

Page 17: ...Fix the wall mounting plate to the wall with 2 screws 2 Hook the door station to the shield tightly by inserting the hooks of shield panel into the slots on the rear panel of the door station 3 Secur...

Page 18: ...oor Open or close the live view Switch the live view among the first door station the second door station and the analog camera Counterclockwise rotation Increase the volume Clockwise rotation Decreas...

Page 19: ...e installing the indoor station make sure that the distance between any two devices is far enough to avoid the howling and echo The distance between two devices is recommended to be longer than 10 met...

Reviews: