AIR CONDITIONING
05 - Units and Parts Checks
SG05-3
TC070-15-01H
Magnetic clutch
Connect battery positive voltage to magnetic clutch terminal A and the A/C
compressor body to ground.
Operation: OK / NG
Refrigerant pressure switch
1. Install the manifold gauge.
2. Disconnect the refrigerant pressure switch connector.
3. Verify the high-pressure side reading of the manifold gauge and continuity
between the refrigerant pressure switch terminals.
Continuity: OK / NG at psi
Fan switch
Remove the climate control unit. Verify that the continuity between the fan switch
terminals is as indicated in the table.
Continuity (switch position OFF): OK / NG
Continuity (switch position 1): OK / NG
Continuity (switch position 2): OK / NG
Continuity (switch position 3): OK / NG
Continuity (switch position 4): OK / NG
Note
Refer to the workshop manual to remove the fan switch.