![background image](http://html1.mh-extra.com/html/mazda/ct-l1005/ct-l1005_training-manual_1751934031.webp)
Basic Climate Control
A/C System
Multiflow Condenser with Sub-cooler
•
The multiflow condenser with a sub-cooler sends the refrigerant to the receiver / drier
and then back into the lower sub-cooling portion of the condenser. Incorporating the
receiver / drier into the condenser ensures that at this last sub-cooling stage (no.4 in the
illustration) only liquid refrigerant is being cooled.
NOTE:
Depending on the model the receiver / drier cannot be replaced separately, i.e. the
condenser must be replaced as a unit.
L1005_008
1 Condenser
4 Sub-Cooling
section
2 Refrigerant
flow
5 Receiver/Drier
3 Cooling
section
Curriculum Training
03-11
Summary of Contents for CT-L1005
Page 1: ...Training Manual Basic Climate Control CT L1005...
Page 20: ...Fundamentals Basic Climate Control Notes 02 14 Curriculum Training...
Page 52: ...A C System Basic Climate Control Notes 03 32 Curriculum Training...
Page 66: ...List of Abbreviations Basic Climate Control Notes 06 2 Curriculum Training...