12.  Reinstall stator by locating the dimple on the stator, and tightening the screw next to the dimple first. Next 

tighten the screw 180 degrees across from the dimple. Install and tighten remaining screws. Reinstall pulley, 
cam, washer, retaining ring, and dust cap. 

 
 
 
 
 
 
 
 
 
 
 
 

13.  Turn new base upside down and apply grease at bottom of the spring hole pockets to eliminate noise 

between spring and base interaction. 

 

 

 

14.  Clean the dome area of new base with alcohol then apply corn starch. 

 

 

 

15.  Reinstall motor and pump to new base. 
16.  Transfer transmission and outer tub onto new base. Use spring tool 22002922 to avoid over stretching the 

springs. 

17.  Transfer cabinet shell onto new base and reassemble washer. Be sure to reattach pressure switch hose to 

back of tub, drain pump hoses with clamps to drain pump, and wire harness to motor. Check all hoses and 
wires to make sure they are secure. 

18. Test washer. 

 

Dimple 

Apply grease at bottom of 
spring hole pockets. 

Apply corn starch to new base 
on dome area after cleaning 
with alcohol. 