background image

6

Closet Installation (stacked washer and dryer):

1"

(25 mm)

1"

(25 mm)

5

1

/

2

"

(140 mm)

24 in.

2

(155 cm

2

)

48 in.

2

(310 cm

2

)

3"

(76 mm)

3"

(76 mm)

6"

(152 mm)

76"

(1930 mm)

Custom under counter installation (dryer only):

1"

(25 mm)

1"

(25 mm)

39" min.

(990 mm)

noTE: 

Some models not recommended for undercounter 

installation.

mobile home - Additional installation requirements: 

This dryer is suitable for mobile home installations. The  

installation must conform to the Manufactured Home  

Construction and Safety Standard, Title 24 CFR, Part 3280 

(formerly the Federal Standard for Mobile home construction  

and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 

MH.

mobile home installations require: 

Metal exhaust system hardware, available for purchase from  

 

your dealer. For further information, see “Assistance or  

Service” section in your Use and Care Guide.

Special provisions must be made in mobile homes to 

 

introduce outside air into dryer. Openings (such as a nearby 

window) should be at least twice as large as dryer exhaust 

opening.

ELECTRICAL REQUIREMENTS

It is your responsibility:

To contact a qualified electrical installer.

 

To be sue that the electrical connection is adequate and in 

 

conformance with the National Electrical Code, ANSI/NFPA 

70 - latest edition and all local codes and ordinances. 

 

The National Electrical Code requires a 4-wire power supply 

connection for homes built after 1996, dryer circuits involved 

in remodeling after 1996, and all mobile home installations. 

 

A copy of the above code standards can be obtained from: 

National Fire Protection Association, One Batterymarch Park, 

Quincy, MA 02269.

To supply the required 3 or 4 wire, single phase, 120/240 

 

volt, 60 Hz, AC only electrical supply (or 3 or 4 wire, 120/208 

volt electrical supply, if specified on the serial/rating plate) 

on a separate 30-amp circuit, fused on both sides of the line. 

Connect to an individual branch circuit. Do not have a fuse in 

the neutral or grounding circuit.

Do not use an extension cord.

 

If codes permit and a separate ground wire is used, it is 

 

recommended that a qualified electrician determine that the 

ground path is adequate.

Electrical Connection

To properly install your dryer, you must determine the type of 

electrical connection you will be using and follow the instructions 

provided for it here.

This dryer is manufactured ready to install with a 3-wire 

 

electrical supply connection. The neutral ground conductor  

is permanently connected to the neutral conductor (white 

wire) within the dryer. If the dryer is installed with a 4-wire 

electrical supply connection, the neutral ground conductor 

must be removed from the external ground connector (green 

screw), and secured under the neutral terminal (center or 

white wire) of the terminal block. When the neutral ground 

conductor is secured under the neutral terminal (center or 

white wire) of the terminal block, the dryer cabinet is isolated 

from the neutral conductor.

If local codes do not permit the connection of a neutral  

 

ground wire to the neutral wire, see “Optional 3-wire 

connection” section.

A 4-wire power supply connection must be used when the 

 

appliance is installed in a location where grounding through  

the neutral conductor is prohibited. Grounding through the 

neutral is prohibited for (1) new branch-circuit installations,  

(2) mobile homes, (3) recreational vehicles, and (4) areas  

where local codes prohibit grounding through the neutral 

conductors.

If using a power supply cord:

Use a UL listed power supply cord kit marked for use with  

clothes dryers. The kit should contain:

A UL listed 30-amp power supply cord, rated 120/240 volt 

 

minimum. The cord should be type SRD or SRDT and be  

at least 4 ft. (1.22 m) long. The wires that connect to  

the dryer must end in ring terminals or spade terminals  

with upturned ends.

A UL listed strain relief.

 

Summary of Contents for NED7300WW

Page 1: ...ELECTRIC DRYER INSTALLATION INSTRUCTIONS INSTALLATION NOTES Date of purchase __________________________________ Date of installation _ _______________________________ Installer ______________________...

Page 2: ...nstructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safet...

Page 3: ...all parts are included NOTE If installing dryer on pedestal do not use leveling legs Optional Equipment Not supplied with dryer Refer to your Use and Care Guide for information about accessories avai...

Page 4: ...water pressure of 20 100 psi 137 9 689 6 kPa You may use the water supply for your washer using the Y connector and short hose if needed which are provided 20 100 psi 138 690 kPa for best performance...

Page 5: ...ith tested spacing of 0 0 mm clearance on sides and rear Additional spacing should be considered for ease of installation and servicing Additional clearances might be required for wall door and floor...

Page 6: ...circuit fused on both sides of the line Connect to an individual branch circuit Do not have a fuse in the neutral or grounding circuit Do not use an extension cord If codes permit and a separate groun...

Page 7: ...own grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This dryer is equipped with a cord having an equipment grounding conductor and a groun...

Page 8: ...ments Power supply cord 3 wire receptacle NEMA Type 10 30R Follow steps 4 6 and 11 13 Then go to Venting Requirements NOTE If local codes do not permit connection of a cabinet ground conductor to neut...

Page 9: ...ns together 5 A B C D A Strain relief tab pointing up B Hole below terminal block opening C Clamp section D Strain relief tab pointing down Power supply cord strain relief 4 wire Power supply cord Con...

Page 10: ...ite or center wire C Connect remaining wires to outer terminal block screws Tighten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw...

Page 11: ...gh strain relief Strain relief should be a tight fit with dryer cabinet and be in a horizontal position Tighten strain relief screw against direct wire cable Now go to step 14 for 4 wire direct wire c...

Page 12: ...nect remaining wires 19 Connect neutral ground wire and neutral wire Connect neutral ground wire E and place hooked end hook facing right of neutral wire white or center wire C of direct wire cable un...

Page 13: ...uctor screw A to an adequate ground Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements Optional 3 wire Connecti...

Page 14: ...ls ceilings or floors The total length should not exceed 7 3 4 ft 2 4 m NOTE If using an existing vent system clean lint from entire length of the system and make sure exhaust hood is not plugged with...

Page 15: ...o a noncombustible portion of mobile home and must not terminate beneath the mobile home Terminate exhaust vent outside Determine vent path Select route that will provide straightest and most direct p...

Page 16: ...2 m 58 ft 17 7 m 48 ft 14 6 m 38 ft 11 6 m 29 ft 8 8 m 21 ft 6 4 m INStall VENT SYSTEM 12 min 305 mm 12 min 305 mm Install exhaust hood 31 Install exhaust hood and use caulking compound to seal exter...

Page 17: ...nnector to the cold water faucet See figure A If Y connector cannot be attached directly to the cold water faucet the short hose must be used See figure B Attach short hose to cold water faucet Screw...

Page 18: ...nt After dryer is in place remove corner posts and cardboard from under dryer Turn on cold water faucet 38 Check that the water faucets are turned on Check for leaks 39 Check for leaks around Y connec...

Page 19: ...uildup may lead to the need for certain part replacement or repair q Select a Time Dry heated cycle and start dryer Do not select Air Only Temperature setting Door Reversal If you prefer to reverse th...

Page 20: ...20 W10240579B W10240583B SP 2009 12 09 All rights reserved Printed in U S A...

Reviews: