9
1. The dryer
must be
installed on a sound level floor capable of supporting its weight. Carpeting
must be
removed from the floor area that the dryer is to rest on.
IMPORTANT:
“The dryer
must be
installed on noncombustible floors only.”
2. The dryer
must not be
installed or stored in an area where it will be exposed to water or weather.
3. The dryer is for use in noncombustible locations.
4. Provisions for adequate air supply
must be
provided as noted in this manual (refer to
Fresh Air Supply
in
Section D
).
5. Clearance provisions
must be
made from noncombustible construction as noted in this manual (refer to
Dryer Enclosure Requirements
in
Section C
).
Even though a 12-inch (30.48 cm) clearance is acceptable, it is recommended that the rear of the dryer be
positioned approximately 2 feet (0.61 meters) away from the nearest obstruction, i.e., wall, for ease of
installation, maintenance, and service. (Refer to the
illustration
below
.)
6. Provisions
must be
made for adequate clearances for servicing and for operation as noted in this manual
(refer to
Dryer Enclosure Requirements
in
Section C
).
7. Dryer
must be
exhausted to the outdoors in an area where correct exhaust venting can be achieved as
noted in this manual (refer to
Exhaust Requirements
in
Section E
).
8. Dryer
must be
located in an area where correct exhaust venting can be achieved as noted in this manual
(refer to
Exhaust Requirements
in
Section E
).
IMPORTANT:
Dryer
should be
located where a minimum amount of exhaust duct
will be
necessary.