background image

3

Electrical Requirements

Before you move your ice maker into its final location, it is 
important to make sure you have the proper electrical 
connection:

A 115 Volt, 60 Hz., AC only, 15- or 20-amp electrical supply, 
properly grounded in accordance with the National Electrical 
Code and local codes and ordinances, is required. 

It is recommended that a separate circuit, serving only your ice 
maker, be provided. Use a receptacle which cannot be turned off 
by a switch or pull chain. 

IMPORTANT: If this product is connected to a GFCI (Ground 
Fault Circuit Interrupter) equipped outlet, nuisance tripping of the 
power supply may occur, resulting in loss of cooling. Ice quality 
may be affected. If nuisance tripping has occurred, and if the 
condition of the ice appears poor, dispose of it.

Recommended grounding method

This appliance must be grounded. This appliance is equipped 
with a power supply cord having a 3 prong grounding plug. The 
cord must be plugged into a mating, 3 prong, grounding-type 
wall receptacle, grounded in accordance with the National 
Electrical Code and local codes and ordinances. If a mating wall 
receptacle is not available, it is the personal responsibility of the 
customer to have a properly grounded, 3 prong wall receptacle 
installed by a qualified electrician.

Water Supply Requirements

A cold water supply with water pressure of between 30 and 
120 psi (207 and 827 kPa) is required to operate the ice maker. If 
you have questions about your water pressure, call a licensed, 
qualified plumber.

Reverse Osmosis Water Supply

IMPORTANT:

Reverse osmosis water filtration systems can be used only 
with ice maker installations that have a gravity drain. A 
reverse osmosis system is not recommended for ice makers 
that have a drain pump installed. 

The pressure of the water supply coming out of a reverse 
osmosis system going to the water inlet valve of the ice 
maker needs to be between 30 and 120 psi (207 and 
827 kPa).

If a reverse osmosis water filtration system is connected to your 
cold water supply, the water pressure to the reverse osmosis 
system needs to be a minimum of 40 to 60 psi (276 to 414 kPa).

NOTE: The reverse osmosis system must provide 1 gal. (3.8 L) of 
water per hour to the ice maker for proper ice maker operation. If 
a reverse osmosis system is desired, only a whole-house 
capacity reverse osmosis system, capable of maintaining the 
steady water supply required by the ice maker, is recommended. 
Faucet capacity reverse osmosis systems are not able to 
maintain the steady water supply required by the ice maker. 

If the water pressure to the reverse osmosis system is less than 
40 to 60 psi (276 to 414 kPa):

Check to see whether the sediment filter in the reverse 
osmosis system is blocked. Replace the filter if necessary.

Allow the storage tank on the reverse osmosis system to refill 
after heavy usage.

If you have questions about your water pressure, call a licensed, 
qualified plumber.

Leveling

It is important for the ice maker to be level in order to work 
properly. Depending upon where you install the ice maker, you 
may need to make several adjustments to level it. You may also 
use the leveling legs to lower the height of the ice maker for 
undercounter installations. 

Tools needed:

Gather the required tools and parts before starting installation.

9" level

Adjustable wrench

NOTE: It is easier to adjust the leveling legs if you have another 
person to assist you.

1. Move the ice maker to its final location. 

NOTE: If this is a built-in installation, move the ice maker as 
close as possible to the final location.

2. Place the level on top of the product to see if the ice maker is 

level from front to back and side to side.

3. Push up on the top front of the ice maker, and then locate the 

leveling screws that are on the bottom front of the ice maker. 

4. Using an adjustable wrench, change the height of the legs as 

follows:

Turn the leveling leg to the right to lower that side of the 
ice maker.

Turn the leveling leg to the left to raise that side of the ice 
maker.

NOTE: The ice maker should not wobble. Use shims to add 
stability when needed. 

5. Push up on the top rear of the ice maker and locate the 

leveling legs that are on the bottom rear of the ice maker. 

6. Follow the instructions in Step 4 to change the height of the 

legs.

7. Use the level to recheck the ice maker to see that it is even 

from front to back and side to side. If the ice maker is not 
level, repeat steps 2 to 5. If the ice maker is level, go to the 
“Connect Water Supply” section.

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, 
fire, or electrical shock.

WARNING

Summary of Contents for MIM1554WRS - Ice Maker

Page 1: ...E 7 ICE MAKER CARE 8 TROUBLESHOOTING 11 WARRANTY 13 S CURIT DE LA MACHINE GLA ONS 14 INSTRUCTIONS D INSTALLATION 15 UTILISATION DE LA MACHINE GLA ONS 21 ENTRETIEN DE LA MACHINE GLA ONS 22 D PANNAGE 25...

Page 2: ...C Best results are obtained between 70 F 21 C and 90 F 32 C This unit must be installed in an area sheltered from the elements such as wind rain water spray or drip When installing the ice maker unde...

Page 3: ...e osmosis system is desired only a whole house capacity reverse osmosis system capable of maintaining the steady water supply required by the ice maker is recommended Faucet capacity reverse osmosis s...

Page 4: ...ch Do not overtighten 4 Place the free end of the tubing into a container or sink and turn on main water supply and flush out tubing until water is clear Turn off shutoff valve on the water pipe NOTE...

Page 5: ...t drain your ice maker will not work Connecting the Drain After ensuring that the drain system is adequate follow these steps to properly place the ice maker 1 Plug into a grounded 3 prong outlet 2 St...

Page 6: ...hinge upside down so that the hinge pin points up Place the hinge on the bottom opposite side of the ice maker and tighten screws 3 Remove the plastic hinge pin sleeve from the old bottom hinge and re...

Page 7: ...denser fan During the harvest cycle you may hear a thud when the ice sheet slides from the evaporator onto the cutter grid When you first start the ice maker you may hear water running continuously Th...

Page 8: ...CE MAKER CARE Cleaning The ice making system and the air cooled condenser need to be cleaned regularly for the ice maker to operate at peak efficiency and to avoid premature failure of system componen...

Page 9: ...partment with a brush attachment on a vacuum cleaner 5 Replace the lower access panel using the four screws 6 Plug in ice maker or reconnect power Interior Components 1 Unplug ice maker or disconnect...

Page 10: ...cover and the two screws 15 Plug in ice maker or reconnect power Vacation and Moving Care To shut down the ice maker 1 Unplug ice maker or disconnect power 2 Remove all ice from storage bin 3 Shut of...

Page 11: ...ormal operation Water is added once per ice making cycle Is the water in the reservoir overflowing This is normal This overflow helps to purge minerals that were removed from the water during the ice...

Page 12: ...ltered or treated Is there mineral scale buildup Clean your ice maker See Ice Maker System in the Cleaning section Are there food items stored in the ice bin Do not store any foods in the ice bin Were...

Page 13: ...appliance is located in a remote area where service by an authorized Maytag servicer is not available 10 The removal and reinstallation of your major appliance if it is installed in an inaccessible l...

Page 14: ...s autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez vous de toujours lire tous les messages de s curit et de vous...

Page 15: ...en cuivre avec un robinet et un syst me de vidange par gravit ou une pompe condensats pour acheminer l eau vers un drain existant Choisir un endroit bien a r o la temp rature est sup rieure 55 F 13 C...

Page 16: ...um REMARQUE Le syst me par osmose inverse doit fournir 1 gal 3 8 L d eau par heure la machine gla ons pour un fonctionnement appropri de la machine gla ons Si l on souhaite un syst me d eau par osmose...

Page 17: ...achine gla ons un tuyau d alimentation en cuivre de est recommand 3 On est maintenant pr t connecter le tuyau en cuivre Utiliser un tuyau en cuivre souple de 6 35 mm de diam tre ext rieur pour l alime...

Page 18: ...de rejet l gout avec un r ducteur de vidange PVC de 1 3 81 cm 2 5 08 cm install directement sous la sortie du tuyau de vidange comme sur l illustration Il faut maintenir un cart anti retour de 1 2 54...

Page 19: ...ace la machine gla ons 6 Mettre la porte de c t Inversion des charni res 1 D visser et ter la charni re sup rieure R installer les vis dans les trous vides de charni re 2 ter les vis du c t oppos inf...

Page 20: ...t produire un son aigu ou de pulsation L eau coulant sur la plaque d vaporation peut produire un son d claboussement L eau coulant de la plaque d vaporation au r servoir d eau peut produire un son d c...

Page 21: ...ns s arr te automatiquement d s que le bac est plein et elle se remet en marche lorsqu il faut plus de gla ons Le bac gla ons n est pas r frig r et la glace fondra un peu Le degr de fonte d pend de la...

Page 22: ...bablement tous les six mois REMARQUE Utiliser une bouteille de 16 oz 473 mL de produit de nettoyage approuv pour la machine gla ons Pour le commander composer le 1 800 442 9991 et demander le num ro d...

Page 23: ...au Si le capuchon de vidange est desserr l eau s coulera du bac eau et la glace sera mince ou il n y aura pas de glace 4 ter les deux vis qui maintiennent le couvercle de la grille de coupe en place e...

Page 24: ...et du d tecteur de niveau de gla ons 14 R installer le couvercle de la grille de coupe et les deux vis 15 Brancher la machine gla ons ou reconnecter la source de courant lectrique Pr cautions prendre...

Page 25: ...ur voir si le tuyau d vacuation est d form La machine gla ons semble bruyante De l eau circule t elle dans la machine gla ons Ceci est le fonctionnement normal L eau est ajout e une fois par cycle de...

Page 26: ...s Voir Syst me de la machine gla ons dans la section Nettoyage Y a t il des aliments dans le bac gla ons Ne pas conserver d aliments dans le bac gla ons Tous les mat riaux d emballage ont ils t enlev...

Page 27: ...service d entretien Maytag autoris n est pas disponible 10 La d pose et la r installation de votre gros appareil si celui ci est install dans un endroit inaccessible ou n est pas install conform ment...

Page 28: ...trademark Trademark of Maytag Corporation or its related companies Marque d pos e Marque de commerce de Maytag Corporation ou de ses compagnies affili es Used under license by Maytag Limited in Canada...