background image

17

PERFORMANCE DATA SHEETS

Interior Water Filtration System

Model UKF8001AXX-750 Capacity 750 Gallons (2839 Liters)

This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The 
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the 
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.

  

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (2.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F ± 5°F (20°C ± 3°C).

It is essential that operational, maintenance, and filter replacement 
requirements be carried out for the product to perform as advertised.

The disposable water filter should be replaced at least every 
6 months.

The filter monitor system measures the amount of water that passes 
through the filter and alerts you to replace the filter. When 90% of the 
filter’s rated life is used, the yellow (Order) light comes on. When 
100% of the filter’s rated life is used, the red (Replace) light comes on, 
and it is recommended that you replace the filter. For models without 
filter status lights, replace the filter every 6 months. Use replacement 
filter model UKF8001. 2014 suggested retail price of $44.99 U.S.A./
$49.95 Canada. Prices are subject to change without notice. 

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of unknown 
quality without adequate disinfection before or after the system. 
Systems certified for cyst reduction may be used on disinfected 
waters that may contain filterable cysts.

Refer to the “Water Filtration System” section for the Manufacturer’s 
name and telephone number.

Refer to the “Warranty” section for the Manufacturer’s limited 
warranty. 

Application Guidelines/Water Supply Parameters

System tested and certified by NSF International against NSF/ANSI Standard 42 for the 
reduction of Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSI 
Standard 53 for the reduction of Lead, Mercury, Atrazine, Benzene, p-Dichlorobenzene, 
Carbofuran, Toxaphene, Cysts, Turbidity, Asbestos, Tetrachloroethylene and Lindane.

Substance Reduction
Aesthetic Effects

NSF Reduction 
Requirements

Average
Influent

Influent Challenge 
Concentration

Maximum
Effluent

Average
Effluent

Minimum%
Reduction

Average% 
Reduction

Chlorine Taste/Odor
Particulate Class I

*

50% reduction
85% reduction

2.00 mg/L
14,000,000 #/mL

2.0 mg/L ± 10%
At least 10,000 particles/mL

0.06 mg/L
370,000 #/mL

**

0.050625 mg/L
196,666 #/mL

97.00%
97.40%

97.52%
99.00%

Contaminant
Reduction

NSF Reduction 
Requirements

Average
Influent

Influent Challenge 
Concentration

Maximum
Effluent

Average
Effluent

Minimum%
Reduction

Average% 
Reduction

Lead: @ pH 6.5
Lead: @ pH 8.5

0.010 mg/L
0.010 mg/L

0.150 mg/L

0.150 mg/L

0.15 mg/L ± 10%
0.15 mg/L ± 10%

< 0.001 mg/L
< 0.001 mg/L

< 0.001 mg/L
< 0.001 mg/L

>99.30%
>99.30%

>99.30%
>99.30%

Mercury: @ pH 6.5
Mercury: @ pH 8.5

0.002 mg/L
0.002 mg/L

0.006 mg/L
0.0059 mg/L

0.006 mg/L ± 10%
0.006 mg/L ± 10%

0.0005 mg/L
0.0018 mg/L

0.0003 mg/L
0.00073 mg/L

91.70%
69.20%

95.00%
88.10%

Benzene

0.005 mg/L

0.0133 mg/L

0.015 mg/L ± 10%

0.0005 mg/L

0.0005 mg/L

96.10%

96.30%

p-Dichlorobenzene

0.075 mg/L

0.210 mg/L

0.225 mg/L ± 10%

< 0.0005 mg/L

< 0.0005 mg/L

>99.80%

>99.80%

Carbofuran

0.040 mg/L

0.0753 mg/L

0.08 mg/L ± 10%

0.027 mg/L

0.008 mg/L

64.60%

73.45%

Toxaphene

0.003 mg/L

0.015 mg/L

0.015 ± 10%

< 0.001 mg/L

< 0.001 mg/L

>93.3%

>93.3%

Atrazine

0.003 mg/L

0.0102 mg/L

0.009 mg/L ± 10%

0.0027 mg/L

0.00105 mg/L

76.30%

89.40%

Asbestos

>99%

126.5 MF/L

10

to 10

fibers/L

††

< 0.17 MF/L

< 0.17 MF/L

>99.99%

>99.99%

Live Cysts

Turbidity

>99.95%
0.5 NTU

122,500 #/L
10.5 NTU

50,000/L min. 
11 ± 1 NTU

< 1 #/L

0.30 NTU

< 1 #/L

0.125 NTU

>99.99%
97.30%

>99.99%
98.80%

Lindane

0.0002 mg/L

0.0019 mg/L

0.002 ± 10%

< 0.00016 mg/L

0.000035 mg/L 91.80%

97.90%

Tetrachloroethylene

0.005 mg/L

0.015 mg/L

0.015 mg/L ± 10%

< 0.0005 mg/L

< 0.0005 mg/L

>96.6%

>96.6%

Water Supply
Water Pressure
Water Temperature
Service Flow Rate

City or Well
35 - 120 psi (241 - 827 kPa)
33° - 100°F (1° - 38°C)
0.78 gpm (2.9 L/min.) @ 60 psi

*

**

††

Class I particle size: >0.5 to <1 um
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
Fibers greater than 10 um in length
Based on the use of Cryptosporidium parvum oocysts

® NSF is a registered trademark of NSF International.

Summary of Contents for MFI2269FRZ02

Page 1: ...the Doors 9 REFRIGERATOR USE 9 Opening and Closing Doors 9 Using the Controls 9 Crisper Humidity Control 11 Ice Maker and Ice Storage Bin 11 Water and Ice Dispenser 12 Water Filtration System 12 REFR...

Page 2: ...ause birth defects or other reproductive harm IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of fire electric shock or injury when using your refrigerator follow these basic precautions SAVE...

Page 3: ...cleaning instructions in Refrigerator Care WARNING Suffocation Hazard Remove doors from your old refrigerator Failure to do so can result in death or brain damage Important information to know about d...

Page 4: ...tallation or cleaning or removing a light bulb turn cooling off or turn the control Thermostat Refrigerator or Freezer Control depending on the model to OFF and then disconnect the refrigerator from t...

Page 5: ...Connect to Water Line 1 Unplug refrigerator or disconnect power 2 Turn OFF main water supply Turn ON nearest faucet long enough to clear line of water 3 Find a to 1 12 7 mm to 31 8 mm vertical cold w...

Page 6: ...the large holes in the mounting clips are down and align the holes with the door studs 2 Rotate the handle so that the mounting clips are flat against the door and slide the handle down to engage See...

Page 7: ...to the connector 6 Check for leaks Replace the top hinge covers Remove and Replace Freezer Drawer IMPORTANT Two people may be required to remove and replace the freezer drawer Graphics are included la...

Page 8: ...val Replacement Top Hinges A Hinge Cover Screw B Top Hinge Cover C 5 16 Hex Head Hinge Screws D Top Hinge A Hinge Pin Cover C Hinge Screws B Bottom Hinge Bottom Hinges A B C Style 2 Handle 2 B A C D C...

Page 9: ...artment doors The doors can be opened and closed either separately or together There is a vertically hinged seal on the left refrigerator door When the left side door is opened the hinged seal automat...

Page 10: ...ld is on the temperature cannot be adjusted Humidity Control on some models The Humidity Control feature turns on a heater to help reduce moisture on the door hinge seal Use in humid environments or w...

Page 11: ...mpartment Turning the Ice Maker On Off The On Off switch is located on the ice maker To turn on the ice maker press the switch to the ON position To manually turn off the ice maker press the switch to...

Page 12: ...ight will illuminate On For continuous light press the LIGHT button a second time The On indicator light will illuminate Off To turn the dispenser light off press the LIGHT button a third time Dispens...

Page 13: ...low the Stainless Steel Cleaner and Polish to come into contact with any plastic parts such as the trim pieces dispenser covers or door gaskets If unintentional contact does occur clean plastic part w...

Page 14: ...The unit may run even longer if the room is warm a large food load is added doors are opened often or if the doors have been left open The refrigerator seems noisy Refrigerator noise has been reduced...

Page 15: ...ice cubes are hollow or small NOTE This is an indication of low water pressure Water shutoff valve not fully open Turn the water shutoff valve fully open Kink in the water source line A kink in the l...

Page 16: ...r system See Water and Ice Dispensers Water from the dispenser is warm NOTE Water from the dispenser is only chilled to 50 F 10 C New installation Allow 24 hours after installation for the water suppl...

Page 17: ...ne Carbofuran Toxaphene Cysts Turbidity Asbestos Tetrachloroethylene and Lindane Substance Reduction Aesthetic Effects NSF Reduction Requirements Average Influent Influent Challenge Concentration Maxi...

Page 18: ...nts Average Influent Influent Challenge Concentration Maximum Effluent Average Effluent Minimum Reduction Average Reduction Chlorine Taste Odor Particulate Class I 50 reduction 85 reduction 2 00 mg L...

Page 19: ...erator or installation instructions 2 In home Instruction on how to use your product 3 Service to correct improper product maintenance or installation installation not in accordance with electrical or...

Page 20: ...20 NOTES...

Page 21: ...RTISSEMENT r frig rateur prendre quelques pr cautions fondamentales y compris les suivantes Pour r duire les risques d incendie de choc lectrique ou des blessures lors de l utilisation du IMPORTANTES...

Page 22: ...nt au moins un produit chimique connu par l tat de Californie pour tre l origine de malformations et autres d ficiences de naissance AVERTISSEMENT Risque de suffoquer Enlever les portes de votre vieux...

Page 23: ...e l ment ou de retirer une ampoule d clairage d sactiver le refroidissement ou placer la commande du thermostat r frig rateur ou cong lateur selon le mod le OFF arr t et d brancher ensuite le r frig r...

Page 24: ...urant lectrique 2 FERMER le robinet principal d arriv e d eau OUVRIR le robinet de puisage le plus proche pendant une p riode suffisante pour que la canalisation d eau se vide 3 Trouver une canalisati...

Page 25: ...ign e vers le haut et la tirer droit pour l extraire de la porte Poign e de style 2 voir les illustrations 1 et 2 R installation des poign es 1 Positionner la poign e de fa on ce que les grands trous...

Page 26: ...auche du r frig rateur 5 Reconnecter la conduite d eau en retirant la bague de blocage tout en poussant fermement la conduite d eau dans la prise 6 Inspecter pour rechercher des fuites R installer les...

Page 27: ...i re t te hexagonale de 5 16 A Cache de l axe de la charni re C Vis de charni re B Charni re inf rieure Charni res inf rieures A B C Poign e Style 2 2 D pose de la fa ade du tiroir A R installation de...

Page 28: ...e sens horaire Il faudra peut tre plusieurs tours et tourner les deux vis de fa on gale 4 R installer la grille de la base UTILISATION DU R FRIG RATEUR Ouverture et fermeture des portes Il y a deux po...

Page 29: ...e de la temp rature de la pi ce Appuyer sur la touche POWERCOLD refroidissement rapide pour r gler le cong lateur et le r frig rateur aux r glages de temp rature les plus bas Appuyer nouveau sur la to...

Page 30: ...s du r frig rateur pour modifier le statut de la pr f rence 3 Enregistrer les pr f rences en appuyant sur la touche DOOR ALARM pendant 3 secondes R glage de l humidit dans le bac l gumes On peut contr...

Page 31: ...e peut tre n cessaire dans certains domiciles Pendant l vacuation de l air l eau peut gicler du distributeur REMARQUE Apr s 5 minutes de distribution d eau continue le distributeur cessera la distribu...

Page 32: ...e d eau peut provoquer une expulsion de l eau et du filtre Toujours faire couler l eau pendant 2 minutes avant de retirer le filtre ou le dispositif de d charge bleu 1 Tourner le filtre dans le sens a...

Page 33: ...ig ration et de cong lation du nouveau r frig rateur sont issues de la technologie DEL Si les lampes ne s allument pas lorsqu on ouvre la porte du r frig rateur et ou cong lateur composer les num ros...

Page 34: ...r haute efficacit et ses ventilateurs L appareil peut fonctionner plus longtemps encore si la temp rature de la pi ce est chaude si une importante quantit de nourriture y est ajout e si les portes son...

Page 35: ...ment ouverte s ou laiss e s ouverte s Ceci permet l air humide de p n trer dans le r frig rateur Minimiser les ouvertures de porte et garder les portes compl tement ferm es Gla ons et eau La machine g...

Page 36: ...Rincer et remplir le syst me de distribution d eau Voir Distributeur d eau et de gla ons La pression de l eau est elle d au moins 35 lb po 241 kPa La pression de l eau du domicile d termine l coulemen...

Page 37: ...et en vertu de la norme NSF ANSI 53 r duction de plomb mercure atrazine benz ne p dichlorobenz ne carbofuran toxaph ne kystes turbidit amiante t trachloro thyl ne et lindane R d de substances Effets e...

Page 38: ...loro thyl ne et lindane R d de substances Effets esth tiques Crit res de r duction NSF Affluent moyen Concentration dans l eau traiter Effluent maximal Effluent moyen de r d minimale de r d moyenne Go...

Page 39: ...et ne comprend pas la main d uvre LE SEUL ET EXCLUSIF RECOURS DU CLIENT DANS LE CADRE DE LA PR SENTE GARANTIE LIMIT E CONSISTE EN LA R PARATION PR VUE PAR LA PR SENTE Le service doit tre fourni par u...

Page 40: ...RTS PAR LA GARANTIE Maytag d cline toute responsabilit au titre de la qualit de la durabilit ou en cas de d pannage ou de r paration n cessaire sur ce gros appareil m nager autre que les responsabilit...

Reviews: