36

2. For Models with Johnson Direct Spark Ignition (DSI) Controller (G760)

Theory of Operation:

Start the drying cycle.  When the gas burner ignites within the

chosen trial for ignition time (6-seconds), the flame sensor detects

gas burner flame and signals the DSI module to keep the gas

valve open as long as there is a call for heat.  The DSI module

will “LOCK OUT” if the gas burner flame is not sensed at the

end of the trial for ignition period.  The trial for ignition period will

be repeated for a total of three (3) retries/trials (the initial try and

two [2] more retries/trials).  If the flame is not sensed at the end

of the third retry/trial (inter-purge period of 30-seconds) the DSI

module will “LOCK OUT” (light emitting diode [L.E.D.] diagnostic

indicator flashes).

A steady L.E.D. indicator indicates normal operation.

No L.E.D. indicator indicates a power or an internal failure has occurred.

3. For Models with Fenwal Controls DSI Module (128937)

Theory of Operation:

Start the drying cycle.  When the gas burner ignites within the

chosen trial for ignition time (8-seconds), the flame sensor detects

gas burner flame and signals the DSI module to keep the gas

valve open as long as there is a call for heat.  The DSI module

will “LOCK OUT” if the gas burner flame is not sensed at the

end of the trial for ignition period.  The trial for ignition period will

be repeated for a total of three (3) retries/trials (the initial try and

two [2] more retries/trials).  If the flame is not sensed at the end

of the third retry/trial (inter-purge period of 30-seconds), the DSI

module will “LOCK OUT” (a red L.E.D. diagnostic indicator will

flash).

An unlit red L.E.D. diagnostic indicator indicates normal operation.

A lit green L.E.D. diagnostic indicator indicates dryer controller is calling for heat and that 

ALL

 interlocks

have been satisfied.

Summary of Contents for MDG50PNH

Page 1: ...l thefiredepartment Installation and service must be performed by a qualified installer service agency or the gas supplier AVERTISSEMENT Assurez vous de bien suivrelesinstructionsdonn esdanscettenotic...

Page 2: ...inflammables proximit decet appareil ou de tout autre appareil We have tried to make this manual as complete as possible and hope you will find it useful The manufacturer reserves the right to make c...

Page 3: ...tion WARNING UNDER NO CIRCUMSTANCES should the dryer door switch lint drawer switch or heat safety circuit ever be disabled IMPORTANT YOUMUSTDISCONNECTANDLOCKOUTTHEELECTRICSUPPLYANDTHEGAS SUPPLY BEFOR...

Page 4: ...cluded with the dryer WARNING DRYER MUST NEVER BE OPERATEDWITHOUTTHE LINTFILTER SCREEN IN PLACE EVENIFANEXTERNALLINTCOLLECTIONSYSTEMISUSED Dryer must not be installed or stored in an area where it wil...

Page 5: ...equirements 9 D FreshAirSupplyRequirements 10 E ExhaustRequirements 11 F ElectricalInformation 17 G GasInformation 20 H Preparation For Operation Start Up 24 I PreoperationalTests 25 J PreoperationalI...

Page 6: ...ubrication 31 D LintDrawerRemoval 32 SECTION VII DATA LABEL INFORMATION 33 SECTION VIII PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS 35 SECTION IX MANUAL RESET BURNER HI LIMIT INSTRUCTIONS...

Page 7: ...ch c DO NOT use any phone in your building d Clear the room building or area of ALL occupants e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions f If y...

Page 8: ...or switch lint drawer switch or heat safety circuit ever be disabled WARNING PERSONALINJURYOR FIRE COULD RESULT should the dryer door switch lint drawer switch or heat safety circuit ever be disabled...

Page 9: ...Manufacturerreservestherighttomakechangesinspecificationsatanytimewithoutnoticeor obligation 0 080 3 7 5 7 OEV NJ 6 7 780 5 0 7 5 FP 6 7 780 5 37 FP 6 7 780 5 02725 KS N 225 23 1 1 0 7 5 FP 6 7 780 5...

Page 10: ...6 NOTE Manufacturerreservestherighttomakechangesinspecificationsatanytimewithoutnoticeor obligation Specifications...

Page 11: ...er IMPORTANT Dryer must be transported and handled in an upright position atALL times The dryer can be moved to its final location while still attached to the skid or with the skid removed To unskid t...

Page 12: ...Requirements in Section D 5 Clearance provisions must be made from noncombustible construction as noted in this manual refer to Dryer Enclosure Requirements in Section C 6 Provisions must be made for...

Page 13: ...d for ease of maintenance 1 inch 2 54 cm maximum for electric dryers A minimum of 12 inches 30 48 cm above the dryer s outer top except along the front of the dryer which may be closed if desired NOTE...

Page 14: ...ributed equally to the dryers The dryer must be installed with provisions for adequate combustion and make up air supply EXAMPLE For a bank of eight 8 dryers two 2 unrestricted openings measuring 3 fe...

Page 15: ...t to which it is connected ALL ductwork joints must be taped to prevent moisture and lint from escaping into the building Additionally inspection doors should be installed at strategic points in the e...

Page 16: ...over 20 feet 6 1 meters a minimum size of 10 inches 25 4 cm must be used HORIZONTAL VENTING When a single 8 inch 20 32 cm horizontal vent is used the ductwork to the outlet cannot exceed 20 feet 6 1 m...

Page 17: ...elbows used exceeds the above noted specifications the cross sectional area of the ductwork must be increased in proportion to the number of elbows or duct run added IMPORTANT For extended ductwork r...

Page 18: ...s being connected to the main common duct must be a minimumof34 1 4 87cm dryerwidth Ductwork should be laid out in such a manner where allowances are made at rear area of the dryer for removal of rear...

Page 19: ...15 HORIZONTAL VENTING Illus C VERTICAL VENTING Illus D...

Page 20: ...he ductwork for periodic inspection and cleaning 9 Whenever the ductwork passes through combustible materials the opening must be 2 inches 5 08 cm larger than the duct all the way around The duct must...

Page 21: ...cted branch circuit The dryer must be connected with copper wire only DO NOT use aluminum wire which could cause a fire hazard The copper conductor wire cable must be of proper ampacity and insulation...

Page 22: ...pipe DO NOT ground to a gas pipe or hot water pipe The grounded cold water pipe must have metal to metal connection ALL the way to the electrical ground If there are any nonmetallic interruptions suc...

Page 23: ...oth cases a strain relief must be installed where the wiring enters the dryer IMPORTANT Aseparate protected circuit must be provided to each dryer Single Phase 1 Wiring Connections Hookup The electric...

Page 24: ...ed can cause irreparable damage to the gas valve which will VOIDTHEWARRANTY WARNING FIRE OR EXPLOSION COULD RESULTdue to failure of isolating or disconnecting the gas supply as noted 1 Gas Supply The...

Page 25: ...the gas valve s internal pressure regulator blocked open so that the gas pressure must be regulated upstream of the dryer The pressure measured at each gas valve pressure tap must be a consistent 10 5...

Page 26: ...pliance Btus being supplied The dryer is provided with a 1 2 N P T inlet pipe connection extending out the back area of the burner box The minimum pipe size supply line to the dryer is 1 2 pipe For ea...

Page 27: ...operation A 1 8 N P T plugged tap accessible for a test gauge connection must be installed in the main gas supply line immediately upstream of each dryer IMPORTANT Pipe joint compounds that resist th...

Page 28: ...ted at the factory prior to shipping However each sail switch adjustment must be checked to ensure that this important safety control is functioning 5 Check bolts nuts screws terminals and fittings fo...

Page 29: ...e ignitions total of three 3 ignition attempts If there is no flame after the third ignitionattemptthemodulewilllockoutuntilitismanuallyreset Toresettheignitionsystem open and close the main door and...

Page 30: ...in progress 2 Press the letter on the keyboard touch pad corresponding to the cycle desired i e key E to start rotate the dryer 3 L E D display will now show Cycle In Progress and Cycle Status meanin...

Page 31: ...SHUTDOWN INSTRUCTIONS If the dryer is to be shutdown taken out of service for a period of time the following must be performed 1 Discontinue power to the dryer either at the external disconnect switch...

Page 32: ...acting the Maytag Co be sure to give them the correct model number and serialnumber sothatyourinquiryishandledinanexpeditiousmanner B PARTS Replacement parts should be purchased from the dealer from w...

Page 33: ...pleted and returned for each individual dryer NOTE Besuretoincludetheinstallationdatewhenreturningthewarrantycard s B WARRANTY For a copy of the manufacturer s commercial warranty covering your partic...

Page 34: ...AND LIQUIDS NOTE Suggested time intervals shown are for average usage which is considered six 6 to eight 8 operational running hoursperday IMPORTANT Dryer produces combustible lint and must be exhaust...

Page 35: ...ng connections and nonpermanent gas connections unions shutoff valves and orifices Motor and drive belts should be examined Cracked or seriously frayed belts should be replaced Tighten loose V belts w...

Page 36: ...r pull drawer out approximately halfway Rotate move lint drawer stop hinge refer to the illustration below downward and pull the drawer out IMPORTANT After replacing the lint drawer back into the drye...

Page 37: ...tain information is required to ensure proper service parts information This information is on the data label affixed to the left side panel area behind the top control access door When contacting the...

Page 38: ...h describes ALL possible options on your particular model 4 TYPE OF HEAT This describes the type of heat for your particular dryer gas either natural gas or liquid propane L P gas electric or steam 5...

Page 39: ...installation of the replacement microprocessor controller computer board reestablish power to the dryer b Start the drying cycle by pressing any of the preset cycles in letters A F c Verify that the...

Page 40: ...tion No L E D indicator indicates a power or an internal failure has occurred 3 For Models with Fenwal Controls DSI Module 128937 Theory of Operation Start the drying cycle When the gas burner ignites...

Page 41: ...re has dropped below 100 F 38 C The clear stop button on the Phase 7 keyboard touch pad must be pressed to clear the error condition The open burner hi limit must be reset manually prior to the start...

Page 42: ...onremainsorreignites While the water jet s are activated the basket tumbler will jog to move the water throughout theload Themicroprocessorwilldisplaythatthesystemwasactivatedandwillcontinue to displa...

Page 43: ...e supplied with a minimum water pipe size of 1 2 and be provided with 40 psi 20 psi 2 75 bar 1 37 bar of pressure For use of optional manual bypass a second source with the same piping and pressure re...

Page 44: ...e coupling must be used in an effort to avoid damaging the electric water solenoid valve NOTE The 3 4 11 5 NH is a standard hose coupling screw thread It is not to be confused with 3 4 N P T The seali...

Page 45: ...r or the water supply is located in an area where it will be exposed to cold freezing temperatures provisions must be made to protect these water lines from freezing WARNING If the water in the supply...

Page 46: ...of the temperature and the control will display S A F E SYSTEM WAS ACTIVATED If the temperature has dropped below trip point the control will turn off the water prior to 10 minutes SYSTEM RESET After...

Page 47: ...corrected the control will continue to monitor the condition for 1 minute before exiting S A F E SYSTEM DISABLED mode SHORTED WATER VALVE This message indicates that the water valve is shorted or tha...

Page 48: ...Maytag113308 4 02 02 04 150...

Reviews: