30
For direct-wired dryers:
1.
Disconnect power.
2.
Disconnect wiring.
3.
Shut off water faucet.
4.
Disconnect the water inlet hose from faucet, then drain the hose. Transport hose
separately.
5.
Make sure leveling legs are secure in dryer base.
6.
Use masking tape to secure dryer door.
Reinstalling the dryer
Follow the “Installation Instructions” to locate, level and connect the dryer.
Changing the Drum Light
The dryer light automatically turns on inside the dryer drum when you open the door.
To change the drum light
1.
Unplug dryer or disconnect power.
2.
Open the dryer door. Locate the light bulb cover on the back wall of the dryer. Remove
the screw located in the lower right corner of the cover. Remove the cover.
3.
Turn bulb counterclockwise. Replace the bulb with a 10-watt appliance bulb only.
Replace the cover and secure with the screw.
4.
Plug in dryer or reconnect power.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.