background image

Service Specifications

 

December 2005 

 

16026830 

© 2005 Maytag Services

 

7

!

WARNING

To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before 

servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires 

removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. 

Service Test – 192 Ice Maker State Test 

 

Display shows the status of the Ice Maker and the Heater (ON or OFF). 
When left Fresh Food door is open the Ice Maker cannot be energized, the test will display dr indicating an open 
Fresh Food door. When the Ice Maker heater is on, the test will display OnH. 

Service Test – 201 Mullion Heater Override  

 

Press the Refrigerator Up Keypad

 

 

or Refrigerator Down Keypad

 

 

 

to change Mullion Heater from 

cycling on with compressor (Off position) to 100% operation (On Position). 

Service Test – 202 Default Defrost Operation 

 

Press the Refrigerator Up Keypad

 

 

or Refrigerator Down Keypad

 

 

 

to change Defrost Operation from 

normal adaptive defrost (Off position) to minimum time between defrosts (On position). 

Service Test – 203 Show Temperature Set points 

 

Press the Refrigerator Up Keypad

 

 

or Refrigerator Down Keypad

 

 

 

to change from showing actual 

temperature (Off position) to showing temperature set points only (On position). 

Service Test – 211 Fresh Food Temperature Adjustment 

 

Press the Refrigerator Up Keypad

 

 

or Down Keypad

 

 

 

to change calibration of Fresh Food 

Temperature plus or minus in 1°F increments up to 

±

 

6°F. 

NOTE: 

Temperature will read in Fahrenheit regardless of what current temperature scale is being used. 

Service Test – 212 Freezer Temperature Adjustment 

 

Press the Refrigerator Up Keypad

 

 

or Down Keypad

 

 

 

to change calibration of Freezer Temperature 

plus or minus 1°F in increments up to 

±

 

6°F. 

NOTE: 

Temperature will read in Fahrenheit regardless of what current temperature scale is being used. 

Service Test – 213 Ice Compartment Temperature Adjustment 

 

Press the Refrigerator Up Keypad

 

 

or Down Keypad

 

 

 

to change calibration of Ice Compartment 

Temperature plus or minus 1°F in increments up to 

 

+ 0 / + 8°F. 

NOTE: 

Temperature will read in Fahrenheit regardless of what current temperature scale is being used. 

Service Test – 221 Reset Default Settings 

 

Press the Refrigerator Up Keypad

 

 

 

and Down Keypad 

 

 

to force to dEF (default factory settings). 

Service Test – 231 Water Filter Usage 

 

Display shows the percent water filter consumption. 100% indicates the filter should be replaced. 

Service Test – 232 Water Filter Days In Use 

 

Display shows the number of days since the filter was installed. 

Service Test – 241 Software Revision Main Control Board 

 

Display shows the Software revision of the Main Control Board. 

Service Test – 244 Software Revision Display Board 

 

Display shows the Software revision of the Display Board. 

Summary of Contents for AFI2538AE Series

Page 1: ...ore handling Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization No Load Performance Controls in Normal Position Kw 24 hr 0 4 Percent Run...

Page 2: ...86 300 ohms 1 8 Condenser motor Rotation facing end opposite shaft RPM Watt Current Clockwise 1120 RPM 3 4 watts 15 115VAC 0 085 amps 15 115VAC Evaporator fan motor Rotation facing end opposite shaft...

Page 3: ...ent Program CODE This value should be validated with the Program CODE printed on the unit serial plate PE0 000 NOTE If the Program CODE is correct the Programming Mode is exited by pressing Door Alarm...

Page 4: ...splay Fd 4 Press the Refrigerator Down Keypad again Sh appears in right display 5 Press again to force defrost Fd and Sh will flash in display indicating unit is in defrost Service Test Mode The servi...

Page 5: ...E If damper is opening or closing it will not allow you to toggle damper and will beep Display will show state CL or OP if Damper is in the process of closing or opening Service Test 131 Mullion Heate...

Page 6: ...Bottle fill you can control state of dispenser lamp Service Test 166 Internal Ice Chute Door Operation Display shows the state of the Internal Ice Chute Door CL closed or OP open NOTE By pushing Actu...

Page 7: ...erature set points only On position Service Test 211 Fresh Food Temperature Adjustment Press the Refrigerator Up Keypad or Down Keypad to change calibration of Fresh Food Temperature plus or minus in...

Page 8: ...through a 10 000 ohm resistor before handling Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization To avoid risk of electrical shock that...

Reviews: