4-2
All controls and circuits are 208 / 240 voltage.
The drive will vary depending on the supply
voltage. Components accessible under the
top panel include:
1. The chemical dispenser assembly,
2. EMI filter,
3. Drive contactor,
4. Supply power transformer,
5. Supply power switch,
6. Line fuse holders,
7. USB Connection,
8. Three port hot water supply valve,
9. Four port cold water supply valve,
10. and the vent, overflow and chemical
injection mixing chamber.
11. The variable frequency drive is enclosed in
a metal box in the top back left corner under
the top panel. This is accessible from the
back panel.
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before
operating.
COMpOnenTS aCCeSSiBLe unDer THe TOp paneL
Chemical
Dispenser
EMI Filter
Drive
Contactor
Supply Power
Transformer
Supply Power
Switch
Line Fuse Holders and USB
Connection Below Center Support
Three Port
Hot Water
Supply Valve
Four Port
Cold Water
Supply Valve
Vent Overflow
Mixing
Chamber
Variable
Frequency Drive