background image

15

The outside end of main vent should have a sweep elbow directed 

downward. 

If main vent travels vertically through the roof, rather than through 

wall, install a 180° sweep elbow on end of vent at least 610 mm  

(2 ft.) above surface of roof. 
The opening in wall or roof shall have a diameter 13 mm (1⁄2") 

larger than vent diameter. Vent should be centred in opening.
Do not install screening over end of vent for best performance.

A main vent can be used for venting a group of dryers. The main 

vent should be sized to remove 5663 l/min. (200 CFM) of air per 

dryer. Large-capacity lint screens of proper design may be used in 

main vent if checked and cleaned frequently. The room where the 

dryers are located should have make-up air equal to or greater than 

CFM of all the dryers in the room.
Unobstructed air openings are required for make up combustion 

air. A static opening of 24 square inches (1 inch

2

 per 1,000 BTU  

of burner) is the minimum required for each dryer in operation.  

A common opening may be used if the return air is distributed 

equally to all dryers in operation.
Back-draft Damper Kit is available from your distributor and should 

be installed in the vent of each dryer to keep exhausted air from 

returning into dryers and to keep exhaust in balance within main 

vent. Unobstructed return air openings are required.
Each vent should enter the main vent at an angle pointing in the 

direction of the airflow. Vents entering from the opposite side 

should be staggered to reduce the exhausted air from interfering 

with the other vents.

The maximum angle of each vent entering the main vent should be 

no more than 30°.
Keep air openings free of dry cleaning fluid fumes. Fumes create 

acids which, when drawn through the dryer heating units, can 

damage dryers and items being dried.
A clean-out cover should be located on the main vent for periodic 

cleaning of the vent system.

If an Exhaust Hood Cannot be Used

Multiple Dryer Venting

DRYER VENTING REQUIREMENTS 

30˚ max.

Air flow

* Minimum clearance above 

any accumulation of 

snow, ice, or debris such 

as leaves

1.

  Remove red cap from gas pipe.

2.

  Connect gas supply to dryer. If the flexible gas hose has  

10 mm (3/8") BSP thread, use the supplied conversion thread 

adapter. Use pipe-joint compound resistant to the action of L.P. 

gas for gas connections.
If necessary for service, open the toe panel. Use a putty knife  

to press on the two toe panel locks located at the top of the  

toe panel. Pull downward on the toe panel to open. Toe panel  

is hinged at the bottom.

Make Gas Connection

DRYER GAS SUPPLY REQUIREMENTS 

3. 

 Open the shut-off valve in the gas supply line.

4.

  Test all connections by brushing on an approved, noncorrosive 

leak-detection solution. Bubbles will show a leak. Correct any 

leaks found.

Summary of Contents for MLG22PD

Page 1: ...ww maytagcommerciallaundry com W11295154A MLG22PR MLG22PD MLG22PN IMPORTANT S precautions including the following WARNING Read all instructions before using the dryer Keep a minimum clearance of 100 mm 4 in between rear of the dryer and any wall To reduce the risk of fire electric shock ...

Page 2: ...s 9 Stacked Washer Gas Dryer Installation Requirements 10 Dryer Venting Requirements 13 Dryer Gas Supply Requirements 15 Installing Stacked Washer Dryer 16 Washer Drain System 19 Leveling 20 Complete Installation 21 Reversing Dryer Door Swing 21 Stacked Washer Dryer Maintenance Instructions 24 If You Need Assistance 25 Electronic Control Setup Instructions 26 Warranty 32 ...

Page 3: ... gas supplier n Post the following warning in a prominent location FOR YOUR SAFETY 1 DO NOT USE OR STORE PETROL OR OTHER FLAMMABLE MATERIALS IN THIS APPLIANCE OR NEAR THIS APPLIANCE 2 DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION 3 DO NOT MODIFY THIS APPLIANCE WARNING RISK OF FIRE FLAMMABLE MATERIALS This is an additional safety alert symbol that alerts you to th...

Page 4: ... be adequate ventilation to replace exhausted air and thus avoid the back flow of gases into the room from appliances burning other fuels including open fires when operating the tumble dryer If in doubt consult the appliance manufacturers Do not obstruct the air supply to the dryer see Installation Instructions for minimum clearances Do not place items exposed to cooking oils in your dryer Oil aff...

Page 5: ... switched on and off by a utility n In case of electrical supply failure remove the load quickly and spread it out to avoid risk of spontaneous combustion SAVE THESE INSTRUCTIONS n Do not dry unwashed items in the dryer n Do not use this dryer if industrial chemicals have been used for cleaning The possible presence of residual quantities of aggressive or decomposed chemicals in the load may produ...

Page 6: ...Electronic Control Coin Drop Enabled 22 Stacked Washer Dryer Model PN Electronic Control Non Pay PR Electronic Control Card Ready n See Electrical Requirements section for earthing instructions n Adequate ventilation has to be provided to avoid the back flow of gases into the room from appliances burning fuels including open fires n The new hose sets supplied with the appliance are to be used Old ...

Page 7: ... 1 Torx T 20 Security 25 mm 1 Hex Head 8 mm 5 16 Socket Wrench Pliers Screwdriver or Bit Socket Wrench that open to 39 mm 19 16 Level Utility Knife 6 mm 1 4 Nut Driver Locking Pliers Caulk Gun and Caulk Vent Clamps Pipe Joint Compound 686 mm 27 Wood Block for installing new exhaust vent suitable for gas type Flashlight optional 13 mm 1 2 and 14 mm Ruler or Measuring Tape 9 16 Open End Wrenches TOO...

Page 8: ...s For more high quality items or to order contact your authorised Maytag distributor Part Number Accessory 8212526 Washer drip tray fits under all 31682 All purpose appliance cleaner 1903WH Laundry supply storage cart 279818 Three way dryer venting kit 285834 Siphon break kit SPECIFICATIONS These units are sold in multiple regions with different requirements for measuring capacity Below are a few ...

Page 9: ...9 DIMENSIONS CLEARANCES Front View Dimensions Clearances Side Clearances Back View Side View Back Top Clearances ...

Page 10: ... should be considered for ease of installation and servicing The doors open more than 180 The washer door is not reversible n Additional clearances might be required for wall door and floor mouldings n Companion appliance spacing should also be considered When installing a gas dryer IMPORTANT Observe all governing codes and ordinances n Check code requirements Some codes limit or do not permit ins...

Page 11: ...on in both poles that provides full disconnection under over voltage category III conditions must be incorporated into the fixed wiring in accordance with local wiring regulations The washer dryer should be positioned so that the disconnection switch is clearly visible and easily accessible to the user This disconnection switch also provides the function of an emergency stop control for the user n...

Page 12: ...requirements Provide a rigid gas supply line to the washer dryer location It should be minimum 12 5 mm 1 2 ID When acceptable to the gas supplier and local codes 10 mm 3 8 ID rigid supply line may be used for lengths under 6 1 m 20 Pipe joint compounds resistant to the action of L P gas must be used Gas connection to the dryer itself should be made by means of a flexible gas hose suitable for the ...

Page 13: ...l Exhaust Vent Rigid metal vent n Recommended for best drying performance and to avoid crushing and kinking Flexible metal vent Acceptable only if accessible to clean n Must be fully extended and supported in final dryer location n Remove excess to avoid sagging and kinking that may result in reduced airflow and poor performance n Do not install in enclosed walls ceilings or floors n The total len...

Page 14: ...art see your parts distributor Provision must be made for enough air for combustion and ventilation Check governing codes and ordinances See Recessed Area and Closet Installation Instructions in the Stacked Washer Gas Dryer Location and Stacked Washer sections A 102 mm 4 outlet hood is preferred However a 64 mm 21 2 outlet exhaust hood may be used A 64 mm 21 2 outlet creates greater back pressure ...

Page 15: ...in vent Unobstructed return air openings are required Each vent should enter the main vent at an angle pointing in the direction of the airflow Vents entering from the opposite side should be staggered to reduce the exhausted air from interfering with the other vents The maximum angle of each vent entering the main vent should be no more than 30 Keep air openings free of dry cleaning fluid fumes F...

Page 16: ...Position the washer dryer so that the rear of the washer is within approximately 900 mm 3 ft of its final location There are four shipping bolts in the rear panel of the washer that support the suspension system during transportation IMPORTANT Remove the four shipping bolts at the rear of the washer before operation 1 Keep the washer dryer in the upright position while removing the shipping bolts ...

Page 17: ... that might clog the inlet valve screens n Check the temperature of the water to make sure that the hot water hose is connected to the hot water faucet and that the cold water hose is connected to the cold water faucet Coupling Washer Connect Inlet Hoses to Washer 1 Attach the cold water hose to the washer s cold water inlet valve Screw on coupling by hand until it is seated on the washer 2 Attach...

Page 18: ...be secure but loose enough to provide a gap for air n Do not lay excess hose on the bottom of the laundry tub Floor drain You may need additional parts See Alternate Parts Secure Drain Hose 1 Drape the power cord over the washer top 2 Move the washer to its final location 3 Place the drain hose in the laundry tub or standpipe as shown 4 Secure the drain hose using the supplied beaded tie strap 4 T...

Page 19: ...er minute The top of the standpipe must be at least 762 mm 30 high and no higher than 2 4 m 96 from the bottom of the washer Laundry tub drain system The laundry tub needs a minimum 76 L 20 gal capacity The top of the laundry tub must be at least 762 mm 30 above the floor Floor drain system The floor drain system requires a siphon break that may be purchased separately The siphon break Part Number...

Page 20: ...l and all four feet are firmly in contact with the floor use a 14 mm or 9 16 open end or adjustable wrench to turn jam nuts counterclockwise as viewed from above on leveling feet tightly against washer dryer cabinet HELPFUL TIP You may want to prop washer dryer with wooden block 3 If washer dryer is not level use a 14 mm or 9 16 open end or adjustable wrench to turn jam nuts clockwise as viewed fr...

Page 21: ...s used up NOTE The dryer door must be closed for the dryer to operate When the door is open the dryer stops but the timer continues to run To restart the dryer close the door and press the cycle button If the burner does not ignite and you can feel no heat inside the dryer shut off dryer for 5 minutes Check that all supply valve controls are in On position and that the electrical cord is plugged i...

Page 22: ...oor hinge 3 Move hinge to other side Reinstall the four screws 4 Reinstall plug strips on opposite side of the inner door 5 Check for fingerprints on the glass Clean if necessary REVERSING DRYER DOOR SWING OPTIONAL 4 Lift the inner door assembly off outer door assembly 5 Remove four Phillips head screws to release centre insert from outer door ring 6 Lift and rotate centre insert 180 degrees 7 Rea...

Page 23: ...the head of the screwdriver under the plugs without scratching the dryer surface and lift up the strip 2 Remove the strike using a Phillips screwdriver 3 Insert strike on the opposite side Reinstall the Door 1 Partially insert the third screw from the top then slide the hinge onto this screw while hooking the hinge into the front panel hole Reattach door to dryer front panel with the remaining thr...

Page 24: ...maining bleach is rinsed from the washer STACKED WASHER DRYER MAINTENANCE INSTRUCTIONS Seal Bellow To clean washer interior 1 Open the washer door and remove any clothing or items from the washer 2 Use liquid chlorine bleach Open the dispenser drawer and immediately add 160 mL 2 3 cup of liquid chlorine bleach to the bleach compartment NOTE Do not add any detergent Use of more than 160 mL 2 3 cup ...

Page 25: ...se a soft damp cloth or sponge to wipe up any spills Occasionally wipe the outside of your washer to keep it looking new Use mild soap and water Do not use abrasive products Cleaning the dispenser drawer The dispenser drawer is removable for easy cleaning 1 Unlock the dispenser drawer for removal by inserting a flat blade screwdriver into the catch release Remove the dispenser drawer 2 Remove the ...

Page 26: ...d reselect desired cycle NOTE When set for free vend operation an ongoing dryer cycle will cancel if the door is opened Washer Control General Washer Dryer User Information SCROLLING OUT OF ORDER MESSAGE FOLLOWED BY A FAILURE OR DIAGNOSTIC CODE SHOWING IN DISPLAY This condition indicates the washer dryer is inoperative Diagnostic codes being displayed on the upper portion of the display pertain to...

Page 27: ... opened DEBIT CARD READY This washer dryer is debit card ready It will accept a variety of debit card systems but does NOT come with a debit card reader Refer to the debit card reader manufacturer for proper washer dryer setup In models converted to a Generation 1 debit card system debit pulses represent the equivalent of one coin coin 1 Control Set up Procedures IMPORTANT Read all instructions be...

Page 28: ...ls Represents the cycle length for free cycles Example 7 45 45 minutes 7 11 WASH LENGTH WASHER 7 11 This is the number of minutes for wash Washer comes from the factory preset with 11 minutes Choose from 9 17 minutes by pressing the POWERWASH button and decrease by pressing the TEMPERATURE button Press the EXTRA RINSE button once to advance to next code 8 00 TYPE OF DRYER PRICING DRYER 8 00 Fixed ...

Page 29: ...nce to advance to next code 6 00 TIME OF DAY CLOCK HOURS WASHER NOTE Uses military time 24 hr clock 6 00 This is the TIME OF DAY CLOCK hour setting select 0 23 hours by pressing POWERWASH button Press the EXTRA RINSE button once to advance to the next code 7 00 SPECIAL PRICE START HOUR WASHER NOTE Uses military time 24 hr clock 7 00 This is the start hour 0 23 hours Select START HOUR by pressing P...

Page 30: ...the DELICATES button three consecutive times for this selection J Ed Enhanced Debit is self selected when a Generation 2 card reader is installed in the washer The Ed option cannot be manually selected or deselected Press the EXTRA RINSE button once to advance to next code L 00 PRICE SUPPRESSION OPTION WASHER This option causes the customer display to show ADD or AVAILABLE rather than the amount o...

Page 31: ...he factory Set by pressing POWERWASH increase button or pressing the TEMPERATURE decrease button Press the EXTRA RINSE button once to advance to next code ELECTRONIC CONTROL SETUP INSTRUCTIONS If cycle counter 9 0C is selected the following is true 1 00 Cycles in HUNDREDS 1 02 200 2 00 Cycles in ONES 2 25 225 TOTAL CYCLES 225 This is VIEW ONLY and cannot be cleared Press the EXTRA RINSE washer key...

Page 32: ...ed in a vended and or multi housing environment ONLY according to instructions attached to or furnished with the product Maytag will pay for factory specified replacement parts for the following components to correct non cosmetic defects in materials or workmanship in the part that prevent functioning of the product and that existed when this commercial appliance was purchased This is a limited 7 ...

Reviews: