450365 - 1
Maytag Co.
31
FORWARD ROTATION SENSOR FAULT D14
A forward rotation fault pertains only to reversing machines. The way this fault works is if the dryer is reversing and
is running a cycle that has the reversing option enabled, if a rotation sensor fault condition is detected, the drive
output would be shut off. Then the dryer will transition to a reversing drive output. If the dryer continues to run without
an issue, the machine will continue to run with the forward drive output disabled until the next cycle is started. If the
Reversing Mode also fails the control will enter a ROTATION SENSOR FAULT disabling the machine. The next cycle
should operate with both drive outputs, that way, if the issue still exists the control will fault out again disabling the fault
drive output.
REVERSE ROTATION SENSOR FAULT
REVERSE ROTATION SENSOR FAULT is identical to FORWARD ROTATION FAULT, however it pertains to the
reversing drive output instead of the forward drive output.
EVENTS
RADIANT SENSOR FAULT COUNT E1
A radiant sensor fault count will occur when a gas model dryer attempts to turn on the burner system and never
receives a 120V return signal within a predefined time.
BURNER IGNITER FAULT COUNT E2
A burner ignition fault count will occur when a gas model dryer attempts to turn on the burner system and receives a
120V on the burner return signal but it does not transition to a 0V return signal within a predefined time.
EXHAUST HIGH LIMIT E3
This location is a count of the times that the exhaust high limit has been sensed in the open position.
BAD COIN COUNT E7
This location is a count of all the bad coin occurrences that were detected from the coin input.
S.A.F.E. DISABLED – WATER NOT CONNECTED
This event pertains only to machines with a fire detection system. If the control senses a lack of water pressure, this
event will appear.