Installation and Operating Instructions for  
ROBA

®

-multiswitch Type 019._00.2 

(B.019+002.EN)

29/03/2022 GC/TH/MA/SU 

Page 2 of 6

Chr. Mayr GmbH + Co. KG
Eichenstraße 1, D-87665 Mauerstetten, Germany
Tel.: +49 8341 804-0, Fax: +49 8341 804-421

www.mayr.com

, E-Mail: 

[email protected]

Application

ROBA

®

-multiswitch fast switching modules are used to 

connect DC consumers to alternating voltage supplies, 
for example electromagnetic brakes and clutches (ROBA-
stop

®

, ROBA

®

-quick, ROBATIC

®

) as well as electromagnets, 

electrovalves, etc.

Fast acting rectifier ROBA

®

-multiswitch 019._00.2

• Consistently controlled output voltage in the entire input 

voltage range

•  Consumer operation with overexcitation or power 

reduction

• Input voltage: 100 – 500 VAC
• Maximum output current I

RMS

: 2 A; 4.5 A

•  UL-approved

Function

The ROBA

®

-multiswitch is used for operation at an input 

voltage of between 100 and 500 VAC, depending on the 
size. After switch-on, it emits the rectified bridge voltage for 
50 ms and then adjusts automatically to a pre-programmed 
overexcitation voltage. After the overexcitation time ends, it 
regulates to the permanently programmed holding voltage. 
For the overexcitation voltage and holding voltage values of 
the standard design, please see the Table at the bottom of 
page 3.
On special designs, deviating values are possible.
The overexcitation time can be adjusted via a DIP switch to 
150 ms, 450 ms, 1 s, 1.5 s and 2 s.

Electrical Connection

 (Terminals)

1 + 2  Input voltage 

(fitted protective varistor)

3 + 4  Connection for external contact  

 

 

 

for DC-side switch-off 

(with an installed bridge, switch-off  

 

only takes place AC-side with a longer brake engagement time)

5 + 6  Output voltage 

(fitted protective varistor)

Dimensions

 (mm)

ROBA

®

-multiswitch units are not suitable 

for all applications, e.g. use of the ROBA

®

-

multiswitch when operating noise-
damped brakes is not possible without 
taking additional measures. The product’s 
suitability should be checked before use.

73.6  (T

ype 019.100.2)

103  (T

ype 019.200.2)

Accessories: 
Mounting bracket set for 35 mm  
rail acc. EN 60715:
Article No. 1802911 

54 

Ø4.5 

4.5 

54 

69 

9

30

17.5

15

5.6

64 

5

22

Summary of Contents for ROBA-multiswitch 019.00.2 Series

Page 1: ...o the directive It is forbidden to start use of the product until you have ensured that the machine accords with the regulations stated in the directive Guidelines on the ATEX Directive Without a conformity evaluation this product is not suitable for use in areas where there is a high danger of explosion For application of this product in areas where there is a high danger of explosion it must be ...

Page 2: ...oltage for 50 ms and then adjusts automatically to a pre programmed overexcitation voltage After the overexcitation time ends it regulates to the permanently programmed holding voltage For the overexcitation voltage and holding voltage values of the standard design please see the Table at the bottom of page 3 On special designs deviating values are possible The overexcitation time can be adjusted ...

Page 3: ...mperature C 40 to 70 Conformity markings Installation conditions The installation position can be user defined Please ensure sufficient heat dissipation and air convection Do not install near to sources of intense heat Special designs with other input and output voltages as well as longer overexcitation times are available on request On special designs deviating values are possible The values stat...

Page 4: ...n series reduces wear If a longer brake engagement time or a quieter switching noise is required please switch AC side For this a bridge must be installed between terminals 3 and 4 Device Fuses To protect against damage from short circuits or earth short circuits please add suitable device fuses to the mains cable As an alternative a motor protection switch can be used This must be adjusted to the...

Page 5: ...s Type tag PO W Coil capacity on overexcitation PO UO x PN UN PH W Coil capacity at reduced capacity PH UH x PN UN tO s Overexcitation time tH s Time of operation with reduction in capacity toff s Time without voltage ton s Time with voltage T s Total time tO tH toff UO V Overexcitation voltage bridge voltage UH V Holding voltage half wave voltage UN V Coil nominal voltage Ieff A RMS current depen...

Page 6: ...ot form ring or bow shapes with the cables Mount good earth connections onto the metal body of the brake Lay control cables separately from power cables or from strongly pulsating cables During operation with a frequency converter please ensure EMC compatible installation of the frequency converter Please always check the holding voltage of the ROBA multiswitch during operation of all components i...

Reviews: