Installation / Connection examples
(continuation)
Installation of a smoothing choke
The installation of a smoothing choke in the coil circuit is
necessary, when the standard cable of the clutch is lengthened.
Reason: it is possible that the max. adjustable torque may not be
achieved due to the cable lengthening. The connection is to be
provided in direct proximity of the control unit and at the terminal
Ku2.
The smoothing choke belongs to the delivery range and can be
used for all sizes.
Technical data: 135 mH, 2 Amp. LxBxH 85x90x95 mm
Repeat order under: Art. No.0802841.
Ku1
Ku2
Smoothing choke
C
lu
tc
h
Shielded connecting lead
Coil connection
EAS -Sm/Zr Control unit
®
//
//
®
Connection signalling relay and clutch
2
1
2
2
2
4
Signalling relay 2
overtemperature
250 VAC/10A
1
4
1
1
1
2
Signalling relay 1
overload
250 VAC/10A
K
u
1
K
u
2
Coil
clutch
96VDC
Connection of EAS
®
-Sm/Zr-clutches
Please observe! The EAS
®
-Sm/Zr-control unit is
adjusted to the corresponding size of the clutch at the
factory. In case other sizes are connected
malfunctions can be caused. Therefore, compare the
sizes of the control unit and clutch.
Comparision table:
EAS
®
-Sm/Zr-
EAS
®
-Sm/Zr-
control unit
clutch
Size/Type/Power
connected with
Size/Type/Power
0/010.000.2/36 Watt
0/400.03x.x/36 Watt
1/010.000.2/46 Watt
1/400.03x.x/46 Watt
2/010.000.2/57 Watt
2/400.03x.x/57 Watt
3/010.000.2/73 Watt
3/400.03x.x/73 Watt
4/010.000.2/105 Watt
4/400.03x.x/105 Watt
0/010.000.2/30 Watt
0/400.00x.x/30 Watt
1/010.000.2/40 Watt
1/400.00x.x/40 Watt
2/010.000.2/45 Watt
2/400.00x.x/45 Watt
3/010.000.2/65 Watt
3/400.00x.x/65 Watt
4/010.000.2/120 Watt
4/400.00x.x/120 Watt
5/010.000.2/155 Watt
5/400.00x.x/155 Watt
0/010.000.2/55 Watt
0/400.01x.x/55 Watt
1/010.000.2/60 Watt
1/400.01x.x/60 Watt
2/010.000.2/80 Watt
2/400.01x.x/80 Watt
3/010.000.2/105 Watt
3/400.01x.x/105 Watt
4/010.000.2/145 Watt
4/400.01x.x/145 Watt
5/010.000.2/256 Watt
5/400.01x.x/256 Watt
Note:
Adjustment of the EAS
®
-Sm/Zr-control unit to a different clutch
size can only be made at the factory!
Technical data
Input voltage
230 VAC, ±10 %, 50-60 Hz
Current consumption
max. 4 Amp./100 % duty cycle
Idle power consumption
< 4 Watt
Coil
NOM
-voltage
96 VDC
Coil
NOM
-power
max. 256 Watt
Coil
NOM
-current
factory setting accordingly
to
mayr
®
-EAS
®
-Sm/Zr-clutch
size
Coil overexcitation
2x I
NOM,
current limitation is
adapted to the respective coil
size.
Torque adjustment
25 % up to 100 % of the coil
current (current stabilization)
Engaging time t
k
5 seconds ±30 %
Protection
IP 20
Ambient temperature
0 °C up to +50 °C
Storage temperature
-20 °C up to +70 °C
Conductor cross section
2,5 mm
2
/ AWG 30-12
Weight
1,5 kg / 3,31 lb
Fuse protection
Mains fuse
F1/F2, (4 AMT, 5x20 mm)
Load fuse
F3, the current is adapted to
the mayr
®
-clutch size. Always
use the same spare fuses.
Overvoltage category
II (two), EN 50178 - 04/1998
Overvoltage protection
For
the
installation
overvoltage category III, a
suitable
overvoltage
protection
is
required
between the input voltage
and the EAS
®
-Sm/Zr control
unit.
Temperature monitoring of the EAS
®
-Sm/Zr control unit
A fitted temperature switch prevent the overheating of the control
unit.
Switch OFF
with >80 °C operating temperature the coil voltage
gets switched off.
New start
only possible, when the EAS
®
-Sm/Zr control unit
cooled down below 40 °C.
Reset
by switching the input voltage OFF and ON.
Temperature monitoring of the clutch coil
The temperature monitoring of the coil can only be made with a
fitted PTC resistor. The PTC resistor is connected to the terminals
P1/P2.
Pre-warning with >+130 °C operating temperature
The coil voltage gets not switched-off yet.
Switch OFF
with >+135 °C operating temperature
The coil voltage is switched off.
New start
only possible, when the coil temperature cooled
down below +120 °C.
Reset
by „Start“clutch is energised.
Short circuit proof coil connection
In case of a short circuit between the coil connections Ku1 and
Ku2 the coil voltage is switched off. Reset of the short circuit
monitoring is made by switching-off the input voltage and removing
the short circuit.
Attention! Mass short circuits are not protected.
Connections Ku1 or Ku2 against earthed metal
components cause mass shorts and, therefore, failures
of the units. A residual current circuit breaker protection
against personal injury and damage to machinery is
required by the customer, which, however, does not
provide a protection against failure of the control unit.