Adjustments 

 

Attention! 

Potentiometer 

and 

code 

bridges  coated  with  lacquer  are  factory 
settings  and  must  not  be  changed.  To 
avoid  any  malfunctions  or  troubles,  the 
operational  functions  are  to  be  observed 
before modification of the codings. 

 
 
 

 
 
 
 
 
 
 
 
 
 

 

 

Engaging time t

(overexcitation time)

 

 

The  engaging  time  t

k

  is  set  to  a  max.  time  of  5  secs.  (factory 

setting). The engaging time is determined by: 

 

Duty cycle 1 

The engaging time is stopped during engagement 
of the clutch and actuation of the limit switch, i.e. 
switch over from overexcitation to torque current 

Duty cycle 2 

When  the  set  time  has  passed  (independent  on 
the  switch  condition  of  the  clutch)  it  is  switched 
over from overexcitation to torque current. 

 

Adjustment of the engaging time t

k

 

The potentiometer is accessible for the engaging time by taking off   
 the plastic cover. 
 The required time can be set with a screw driver.                      
 Right-hand contact – max. time (5 secs.) 

Left-hand contact –   min. time (approx. 50 ms) 

 

Duty cycle 1 (factory setting) 
Switch  over  of  the  coil  current  from  overexcitation  to  the  set 
torque-current,  when  the  clutch  engages  and  the  limit  switch  is 
“actuated”. Residual engaging time t

k

 is set to zero 

 

Please  observe!  0,7  secs.  slowing  down  time  of 
the  overexcitation.  
The  overexcitation  2  x  I

NOM 

is 

switched off approx. 7 secs. later after the limit switch 
has been actuated guaranteeing a better engagement 
of the clutch. The 0,7 secs. slowing down time can be 
set to “zero” by changing the coding. 

 

I

Overexcitation
2 x I

NOM

Adjusted
torque

Clutch engaged

Limit switch

Engaging  time tk

*

The remaining engaging
time is set to zero.
No overexcitation

*

 

 

Duty cycle 2

 (observe coding!) 

Application: It is used for acceleration of large masses.   
Switch  over  of  the  coil  current  from  overexcitation  to  the  set 
torque-current, when the engaging time t

has passed. A repetitive 

switching ON and OFF within the engaging time t

k

 does not cause 

an overload signal. Before the time t

k

 has passed the clutch must 

remain engaged and the limit switch must be actuated.

 

 

 

Overexcitation up to the expiry
of the adjusted engaging time

*

I

Overexcitation
2 x I

NOM

Adjusted 
torque

Clutch engaged

Limit switch

Engaging time t

 k 

*

 

 
 

Please observe! Danger due to overheating of the 
coil. 
There is a risk of coil overheating due to frequent 
starts  “Tipp  operation”  with  overexcitation,  which  can 
cause  a  failure  of  the  coil.  The  engaging  time  t

k

  is  to 

be set to the minimum time to prevent this. 

 

Multi-Start

 (observe coding!) 

 

I

Overexcitation
2 x I

NOM

adjusted
torque

Clutch
engaged

Limit switch

Multistart

Multistart

(single start)

Engaging time t

      k

Overexcitation
 time

Overexcitation
time

 

 

Application: change of loads during an operational process. 
The  Multi-Start  allows  a  repeated  switching-ON  of  the 
overexcitation during an operational process and can only be used 
with duty cycle 2.  

Please observe! Danger due to overheating of the 
coil  if  the  resistor  is  not  used  or  if  it  is  defective. 
There is a risk of coil overheating due to too big cycle 
sequence  which  can  cause  a  failure  of  the  coil.  The 
cycle sequence is to be limited and the overexcitation 
time  (=engaging  time  t

k

)  is  to  be  set  to  a  minimum 

time. 

 

Overexcitation 2x I

NOM

 

The overexcitation of the coil amounts to 2 x I

NOM

 of the max. coil 

current.  Switch  over  from  overexcitation  to  the  torque  current  is 
made in dependency on the engaging time t

k

 

Engaging time

 t

k

    (factory setting)

Torque adjustment

Potentiometer

25 to 100 %

Analogue 0-10 VDC

Potentiometer

(Factory setting)

Torque adjustment

Potentiometer max. 5 secs.

Delay

Single-start

0.7 sek.

Start - operation

0 sec.

2

(overexcitation)

Multi - Start