5.
Check that the upper anchor tube is straight, using a spirit level. (cf. illus.)
Screws that are not tightened correctly will work loose.
If screws are not tightened firmly enough, there will not be sufficient tensile
force to trigger self-locking. If the screws are tightened too firmly and over-
stressed, the screw connection may slacken.
Tighten the screw manually using the enclosed hex key and extension. Exert
as much force as possible. With the enclosed tools there is virtually no risk
of over-stressing.
The correct torque for a torque wrench is 210 Nm.
If the sunshade is to be in a vertical position, the anchor plate must be
dowel-fastened absolutely vertically.
It may be necessary to align the anchor tube with the help of washers.
Power supply
1.
The connection of ground cable and power supply for the umbrella must be absolutely
waterproof. The ground cable (for heavy current: min. 5-pole, min. 4mm², cable cross
section) must be laid to suit the electric load and the length of the lead wire by a qualified
electrician.
Electric installation work should be carried out solely by a certified
electrician. Disregarding this warning may result in serious personal
injuries.
Caution
apply the spirit level on two sides
Danger
Caution
90°
90°