42
MODEL
21967 FLAMEHEATER
10.5 KW
13+
1.5mm
G30/G31
28-30/37mbar
13 B/P
1.5mm
G30
30mbar
G30
50mbar
13 B/P
1.3mm
Nominal heat input: (Hs)
Appliance category:
Reference gas:
Normal gas pressure:
Injector size:
COUNTRY OF DESTINATION
I3+ for
BE-CH-ES-FR-GB-GR-IE-IT-PT
28-30/37mbar
I3B/P for
CY-CZ-DK-EE-FI-LT-LV-MT-NL-NO-SE-SI-SK-BG-RO-TR
30mbar
I3B/P for
AT-DE
50mbar
TECHNICAL SPECIFICATIONS
GUARANTEE AND SERVICE
Your new MaxxGarden product comes with a 12 month warranty. Defects affecting product func
-
tionality may be corrected by replacement or repair provided the product is used and maintained
in accordance with the instructions. This does not apply to damage or wear sustained by improper
use of the accessories or the appliance. Your statutory rights are not affected. Documentation,
packaging, and product specifications may change without notice.
CUSTOMER SERVICES
If you wish to return your product for a full refund the item must be unused, in its original packaging
and returned in a sellable condition. Please contact our Customer Service team within 24 hours
who will be able to assist with your enquiry.
If they advise you to return the product to us please pack it carefully and include a note with your
name, address, daytime telephone number and details of the fault. If the product is still under
guarantee please include proof of purchase.
PROBLEM
PROBABLE CAUSE
SOLUTION
Pilot will not stay on
Debris around pilot
Loose connections
Thermocouple bad
Gas leak in line
Lack of fuel pressure
Clean dirty area
Tighten connections
Replace thermocouple
Check connections
Tank near empty. Refill LPG tank.
Pilot will not light
Gas valve may be OFF
Tank fuel empty
Opening blocked
Air in supply system
Loose connections
Turn the gas valve ON
Refill LPG tank
Clean or replace opening
Purge air from lines
Check all fittings
Burner will not light
Pressure is low
Opening blocked
Control not ON
Thermocouple bad
Pilot light assembly bent
Not in correct location
Tank near empty. Refill LPG tank.
Remove and clean
Turn valve to ON
Replace thermocouple
Place pilot properly
Position properly and retry