background image

 

 

 

 

4.1  Connecting the electrical supply 

All Maxx Air models require regular  3 prongs, ground with 120 volt power supply. Plug electrical cord into receptacle. If 

using an extension cord be sure it is rated for at least 20 amps for the distance your cord is running. To be safe – make sure 

no other equipment is plugged into the same circuit. The  Maxx Air should run smoothly on 20 amp, 120 volt,  and 60 Hz 

circuit.  

 

4.2 Connecting the water supply 

Connect  standard  water  hose  to  female  fitting  on  the  right  side  of  your  Maxx  Air  (looking  at  the  fan  blade  side).  If  your 

water  pressure  is  above 60  pounds per  square  inch (p.s.i).  you  must use  a  pressure  regulator  (which  can  be  found  at  your 

local hardware store). 

Note:

 Do not connect to water source exceeding 60 p.s.i. – this can cause damage to your Maxx Air. 

 

5.0  Operating procedures 

Back your Maxx Air unit up to a fresh air source such 

as  an  open  door  or  window  so  the  unit  can  pull  in 

fresh air from the outside. Next, make sure you have 

a natural exhaust at the opposite end of the room, bay 

or building such as a window, door or bay door. This 

will  ensure  maximum  efficiency  from  your  unit. 

Finally  make  sure  there  are  no  obstructions  between 

your  Maxx  Air  and  the  people  /  area  you  need  to 

cool. 

 

5.1  Filling the units reservoir with water 

Once your  water hose is connected  – open the  water flow 

valve (located on the front of your unit) only one and quarter (1 1/4) turns. 

This water flow valve adjusts the amount of water 

to the unit.

 Next, turn water on and fill the reservoir with water. Listen carefully. You can hear water filling the reservoir. 

Check your water connection  – make sure there is no dripping. Once the reservoir is filled with water the float valve will 

automatically shut off the water source. When you no longer  

hear the water running – you know that the float valve is fully operational  

(the water turns off automatically) and you are now ready to turn on the water pump.  

Warning! Do not run water pump without water in the reservoir. 

 

5.2  Turn-on pump  

To turn-on the water pump - flip the toggle switch for the water pump to on. Switch is  

located on front side of unit. 

Warning! Do not run water pump without water in the  

reservoir

. The water pump will now begin pumping water to the top of the unit so that  

gravity will allow the water to run down the backside of unit inside and on the cooling  

pads. (If the water is dripping off of the pads on to the floor – turn your fan on low –  

 

 

Top: Water control valve 

 controls water to 

units water reservoir. Open 1 ¼ turns. 
Bottom: Water hook-up for cleaning and 
flushing water reservoir.  
 

NOTE: EXTENDED COOLING ZONE: 40’ TO 50’ FROM MAXX AIR 

UNIT. AIR MOVEMENT INCLUDES WARM AIR MIXING WITH COOLED 

AIR. 

Summary of Contents for EC36D1

Page 1: ...ile this owner s manual in a safe place for future reference It contains operating procedures maintenance procedures trouble shooting guide replacement parts guide order form and contact information Y...

Page 2: ...rcuit is strongly recommended WARNING Check your units electric power cord for insulation breaks cracks or fraying If any of these conditions are found DO NOT USE See your distributor for immediate se...

Page 3: ...supply 4 2 Connecting the water supply 5 0 Operating procedures 5 1 Filling the units reservoir with water 5 2 Turn on pump 5 3 Adjust water flow 5 4 Turn on Fan 6 0 Daily Operating procedures 6 1 Tur...

Page 4: ...433 1626 2 0 How Evaporative Cooling Works Keeping in mind that regular fans only circulate same temperature air same humidity your Maxx Air portable evaporative cooler takes that same existing air co...

Page 5: ...1 Filling the units reservoir with water Once your water hose is connected open the water flow valve located on the front of your unit only one and quarter 1 1 4 turns This water flow valve adjusts th...

Page 6: ...n fan to low let cooling pads get saturated then turn fan on high for cooling Adjust the water flow Your Maxx Air operates most efficiently and maintains uniform cooling pad wetness with the water con...

Page 7: ...ce 15 minutes before quitting time turn off the water pump and let the fan run 10 15 minutes to dry out the cooling pads before leaving Inspect the cooling pads to make sure they are thoroughly dry th...

Page 8: ...xx Air units usually operate at peak performance at 1 turns Repair as necessary Reduce the water flow with the water control valve located on the front of the unit Search for leaks and repair as neces...

Page 9: ...p Flush water from unit s water reservoir more frequently See section 7 4 8 0 Storage Remove pads as described above in 7 2 and rinse pads clean with fresh water Dry cooling pads in sunlight Drain wat...

Page 10: ...reserves the right to demand and receive written evidence of the date of purchase before undertaking its obligations under this warranty The right to demand and receive written evidence of date of pur...