OPERATION OF THE CONTROL SYSTEM
DUAL DIRECTION SYSTEM (Refer drawing B3424)
This system provides means of controlling the Windlass via a Reversing Solenoid which
is actuated by a self centering UP/DOWN toggle switch type remote control or the
footswitches.
An indicator light on the remote control glows when the power is “ON” and the system
can be operated.
WARNING: When using the Windlass DO NOT SWITCH IMMEDIATELY FROM
ONE DIRECTION TO THE OTHER WITHOUT WAITING FOR THE WINDLASS TO
STOP AS THIS COULD DAMAGE THE WINDLASS. Abuse is not covered by
Warranty.
The Breaker/Isolator Panel provides protection for the main supply cables and
means to isolate the circuit.
WARNING: When the Isolator Switch is “ON” the system can be activated at
either the footswitches or the remote.
When the system is not being used, ensure that the Isolator Switch is turned
“OFF”.
WARNING: This system provides protection for the motor from excessive current
and short circuit. It does not provide protection against excessive heat build up
due to prolonged operation or repeated operation under overload conditions.
Make sure you give the motor time to cool. Abuse is not covered by Warranty.