EN
User Manual
G
eneral
d
escription
Display: LCD screen with background, max reading of
“1999”
Operating temperature:
0°C - 40°C
(32°F
-
104°F)
Operating humidity:
<80% RH
Storage temperature:
-10°C - 60°C
(14°F
-
122°F)
Storage humidity:
<70% RH
Sampling updates:
3/mp
Measurement range selection: automatic or manual
Measurement category:
Cat III 500V
Power Source:
1x 6F22 9V elem
Size:
144 x 70 x 32mm
Weight:
~200g (with battery)
Overload Protection and Overvoltage Protection
Auto Turn On/Off function
Data Hold Function
s
afety
i
nforMation
To avoid possible electric shock or personal injury, fol-
low these guidelines:
•
Protect yourself against electric shock.
•
Avoid any misuse or improper usage to protect
the device from any damage.
•
Before measuring current, check the Meter’s ac-
cessories (fuses, probes), ensure the good wor-
king condition, to avoid any damage. Do not use
the device with damaged test leads.
•
Do not use the Meter around devices with high
electricity and frequency which can generate
interference, due to avoid misuse, false measu-
rement, damage or immeasurable values on the
screen.
•
Use the device only according to the guidlines
and for appropriate measurements. If you misuse
the Meter, it cannot work properly in the future.
•
Do not operate the Meter around explosive gas,
vapor, or dust.
•
Check the device before every usage, verify the
Meter’s operation in the selected position and en-
sure the connection of the test leads.
•
If you do not know the range what you want to
measure, set up the switch to the highest measu-
ring value and go backwards until it achieves the
appropriate range.
•
To avoid any damage, do not use the device for
measuring more than the rated input voltage.
•
Use caution when working with voltages above
60V dc, or 30V ac. These voltages pose a shock
hazard.
•
When using the probes, keep the fingers behind
the finger guards.
•
Before rotating the range switch to select functi-
ons, disconnect test leads from the circuit under
test.
•
To avoid possible damage to the Meter or to the
equipment under test, disconnect circuit power
and discharge all high-voltage capacitors before
testing diodes, continuity or resistance.
•
Before measuring current turn OFF power to the
circuit before connecting the Meter to the circuit.
•
Replace the batteries as soon as the battery indi-
cator appears on the screen.
•
Disconnect test leads before opening the case or
the battery door.
•
Do not use the Meter if it operates abnormally.
•
If the product is not in use, remove the battery
and store the Meter in a cool, dry place, and do
not store in highly humid environment.
•
To avoid fire, or any damage, replace fuses only
with the specified ratings: F 200mA/250V, F
10A/250V.
•
Do not use the device if the back battery cover is
open or does not fit closed and fixed properly.
1. LCD display
2. POWER – turn on/off button
3. HOLD – Date Hold button
4. Function switch
5. „A” jack – Input for 10A current measurements
6. Light sensor (for the backlight)
7. NCV LED –
Voltage detector function display LED
8. Backlight turn on/off button
9. „COM” – common input terminal
10. mA/V/
/Ω/ terminal, (hereafter „V” terminal)
f
Unction
HOLD button
Data hold function.To hold the present reading, press
the data hold button for a while. Press the button again
to resume normal operation.
Power button
Press the power button once to turn the device on or
off.
1
2
6
7
8
9
10
3
4
5