- 12 -
Option: hydraulic cable entry brake / cable discharge
(can be retrofitted)
ATTENTION:
only use compacted cables with a "smooth" surface!
ASSEMBLY:
Please refer to the retrofitting instructions which have to be ordered separately.
DESCRIPTION:
FUNCTION / OPERATION:
Cable entry brake
works automatically with the "Pull load" function.
Cable discharge
is activated by the "Release brake permanently" function (approx. 3 s).
Activate cable discharge: press once for approx. 3 s
Stop cable discharge: press once briefly
ADJUSTMENT:
Cable entry brake
Cable discharge
Cable discharge speed
Swivel the cover of the control unit guard up.
Upper throttle:
Loosen the lock nut and
* turn to the left to reduce the speed
* turn to the right to increase the speed
Retighten the lock nut.
+
-
-
+
Cable entry brake
Swivel the cover of the control unit guard up.
Lower throttle:
Loosen the lock nut and
* turn to the left to reduce the brake action
* turn to the right to increase the brake action
Retighten the lock nut.