background image

6

MXN102

Operating Instructions

Interchange Information

Can use 5/8” to 2” 18 gauge brad nails designed for the following tools: Bostitch® BT125SK-2 & BT200K-2, Campbell
Hausfeld®NB0030 & NB0040, DeWalt® D51238K, Paslode® T125-F18 & T200-F18, Porter Cable® BN125 & BN200, and Senco
Finish Pro® 15 & 18.

1

1

MPA
bar
psi

1

1

7

.

.

.

.

5

9

1

6

8

1

1

3

4

1

Recommended Hookup

Quick

Plug

Quick

Coupler

Air

Hose

Quick Plug

(Optional)

Quick

Coupler

(Optional)

Filter - Regulator

3

General Safety
Information 

(Continued)

Always assume the nailer contains
nails. Respect the tool as a working
implement; no horseplay. Always
keep others at a safe distance from
the work area in case of accidental
discharge of nails. Do not point the
tool toward yourself or anyone
whether it contains fasteners or not.
Accidental triggering of the nailer
could result in death or serious per-
sonal injury. 

Do not drive a
nail on top of
other nails. The
nail could glance
and cause death
or a serious punc-
ture wound.

Do not operate
or allow anyone
else to operate
the nailer if any
warnings or
warning labels
are not legible.
Warnings or warning labels are locat-
ed on the nailer magazine and body. 

Do not drop or throw the tool.
Dropping or throwing the tool can
result in damage that will make the
tool unusable or unsafe. If the tool
has been dropped or thrown, exam-
ine the tool closely for bent, cracked
or broken parts and air leaks. STOP
and repair before using or serious
injury could occur.

Caution indicates 
a potentially haz-

ardous situation which, if not avoided,
MAY result in minor or moderate
injury.

!

CAUTION

Operating The Nailer

RECOMMENDED HOOKUP

The illustration below shows the
recommended hookup for the nailer.

1. The air com-

pressor must
be able to
maintain a
minimum of 60
psi when the nailer is being used. An
inadequate air supply can cause a
loss of power and inconsistent 
driving.

2. Always use air supply hoses with a

minimum working pressure rating
equal to or greater than the pres-
sure from the power source if a reg-
ulator fails, or 150 psi, whichever is
greater. Use 3/8” air hose for runs
up to 50’. Use 1/2” air hoses for 50’
run or longer. For better perfor-
mance, install a 3/8” quick plug (1/4”
NPT threads) with an inside diame-
ter of .315” (8mm) on the nailer and
a 3/8” quick coupler on the air hose.

3. Use a pressure regulator on the

compressor, with an operating pres-
sure of 0 - 125 psi. A pressure regu-
lator is required to control the oper-
ating pressure of the nailer between
60 and 100 psi. 

Do not make any modifications to the
tool without first obtaining written
approval from Maxus. Do not use the
nailer if any shields or guards are
removed or altered. Do not use the
nailer as a hammer. Personal injury or
tool 
damage may occur.

Avoid long extended periods of
work with the nailer. Stop using the
nailer if you feel pain in hands or
arms.

Always check that the Work Contact
Element (WCE) is operating proper-
ly. A nail could accidentally be dri-
ven if the WCE is not working prop-
erly. Personal injury may occur (See
"Checking the Work Contact
Element" Section).

Disconnect air supply and release
tension from the pusher before
attempting to clear jams because
fasteners can be ejected from the
front of the nailer. Personal injury
may occur.

Notice indicates 
important infor-

mation, that if not followed, MAY
cause damage to equipment.

Avoid using the nailer when the
magazine is empty. Accelerated
wear on the nailer may occur.

Clean and check all air supply hoses
and fittings before connecting the
nailer to an air supply. Replace any
damaged or worn hoses or fittings.
Tool performance or durability may
be reduced.

NOTICE

MXN102

Operating Instructions

!

WARNING

60 psi
Min.

100 psi
Max.

150 psi or greater

3/8” I.D.

Notes

Summary of Contents for MXN102

Page 1: ...xtreme Duty Three 3 Years IronForce by Campbell Hausfeld One 1 Year Farmhand Three 3 Years Maxus Five 5 Years 2 WHO GIVES THIS WARRANTY WARRANTOR Campbell Hausfeld Scott Fetzer Company 100 Production Drive Harrison Ohio 45030 Telephone 800 543 6400 3 WHO RECEIVES THIS WARRANTY PURCHASER The original purchaser other than for purposes of resale of the Campbell Hausfeld product 4 WHAT PRODUCTS ARE CO...

Page 2: ...e regulator fails the pressure delivered to the tool must not exceed 200 psi The nailer could explode which will cause death or serious personal injury Never use gasoline or other flammable liquids to clean the nailer Never use the DANGER nailer in the presence of flammable liquids or gases Vapors could ignite by a spark and cause an explosion which will result in death or serious personal injury ...

Page 3: ...n the nailer is being used An inadequate air supply can cause a loss of power and inconsistent driving 2 Always use air supply hoses with a minimum working pressure rating equal to or greater than the pres sure from the power source if a reg ulator fails or 150 psi whichever is greater Use 3 8 air hose for runs up to 50 Use 1 2 air hoses for 50 run or longer For better perfor mance install a 3 8 q...

Page 4: ...TIAL TRIP NAILER Check the opera tion of the Work Contact Element WCE trip mechanism before each use The WCE must move freely without binding through its entire travel distance The WCE spring must return the WCE to its fully extend ed position after being depressed Do not operate the nailer if the WCE trip mechanism is not operating properly Personal injury may occur 1 Disconnect the air supply fr...

Reviews: