Installation
Maxtor D740X-6L 20.0/40.0/60.0/80.0GB AT
3-7
/0()*+,-.
You can also daisy-chain two drives on the ATA bus interface by using their Drive
Select (DS) jumpers. To use the DS feature, the CS jumper must not be installed.
To configure a drive as the Master (Device 0), a jumper must be installed on the DS
pins.
Note:
The order in which drives are connected in a daisy chain has no
significance.
1,-.)234/5-/23
In combination with the current DS or CS jumper settings, the Slave Present (SP)
jumper can be implemented if necessary as follows:
Note:
The CS position doubles as the Slave present on this drive.
• When the drive is configured as a Master
(
DS jumper installed or CS
jumper installed, and the Cable Select signal is set to (0), adding an
additional jumper (both jumpers DS and CS now installed) will indicate
to the drive that a Slave drive is present. This Master with Slave Present
jumper configuration should be installed on the Master drive only if the
Slave drive does not use the Drive Active/Slave Present (DASP–) signal
to indicate its presence.
,-.6/35*%+21//23
The PK position is used as a holding place for the jumper for a slave drive in systems
that do not support Cable Select. The pins used for the parking position are vendor
unique.
Summary of Contents for D740X-6L 20.0 AT
Page 1: ......
Page 10: ...Table of Contents ii Maxtor D540X 4K 20 0 40 0 60 0 80 0GB AT...
Page 14: ...About This Manual 1 4 Maxtor D740X 6L 20 0 40 0 60 0 80 0GB AT...
Page 18: ...General Description 2 4 Maxtor D740X 6L 20 0 40 0 60 0 80 0GB AT...
Page 38: ...Installation 3 20 Maxtor D740X 6L 20 0 40 0 60 0 80 0GB AT...
Page 66: ...Basic Principles of Operation 5 17 MaxtorD740X 6L 20 0 40 0 60 0 80 0GB AT...
Page 88: ...ATA Bus Interface and ATA Commands 6 22 Maxtor D740X 6L 20 0 40 0 60 0 80 0GB AT...