Maxtec Handi+ R218P12 Operating Manual And Instructions Download Page 8

      866.4.Maxtec    www.maxtec.com

2

1.2 Symbol Guide

The following symbols and safety labels are found on the the Handi+:

 

1.3 Description

The Maxtec Handi+ oxygen analyzer is designed to monitor oxygen 
concentration in the patient-breathing environment. It is one of a full line of 
oxygen analyzers by Maxtec. The Handi+ oxygen analyzer utilizes the Maxtec

 

MAX-250 oxygen sensor and is engineered for fast response, maximum 
reliability and stable performance. The Handi+ is designed primarily for spot-
checking of oxygen levels delivered by medical oxygen delivery equipment and 
respiratory care systems. Its lightweight, compact size, extended battery life, 
and "auto off" feature makes this oxygen analyzer ideal for portable oxygen 
analysis by qualified heath care professionals. 

 2.0 CALIBRATING THE Handi+

2.1  Before You Begin

A protective film covering the threaded sensor face must be removed and the 
sensor allowed to “breath” for at least 30 minutes. Next, the Handi+ Oxygen 
Analyzer should be calibrated. Thereafter, Maxtec recommends calibration on 
a weekly basis. However, more frequent calibration will not adversely affect 
product performance.

Do not throw away. Follow local 

guidelines for disposal.

!

Follow instructions for use

On/off Button

Do Not 

Warnings 

Calibration Button

Meets ETL standards

EC REP

Authorized Representative 
in the European Community

LOT

IPX1

Lot code/Batch code

Drip Proof

SN

Serial Number

REF

Catalog Number

Manufacturer

Federal law (USA) restricts this device 
to sale by or on the order of a physician.

Contains acid

Contains lead

only

Summary of Contents for Handi+ R218P12

Page 1: ...H Handi O P E R A T I N G M A N U A L I N S T R U C T I O N S F O R U S E R 2 1 8 P 1 2 R218M12 Rev J CAL...

Page 2: ......

Page 3: ...s from the date of shipment from Maxtec under normal operating conditions and provided that the Handi is properly operated and maintained in accordance with Maxtec s operating instructions Should Hand...

Page 4: ...Improper use of this device can cause inaccurate oxygen readings which can lead to improper treatment hypoxia or hyperoxia Follow the procedures outlined in this user manual CAUTION Indicates a potent...

Page 5: ...ation A 3 2 4 Direct Flow Calibration Configuration B 4 3 0 OPERATING THE HANDI 4 4 0 FACTORS INFLUENCING ACCURATE READINGS 5 4 1 Elevation Changes 5 4 2 Temperature Effects 5 4 3 Pressure Effect 5 4...

Page 6: ......

Page 7: ...blank The analyzer turns off after 1 3 minutes if no buttons are pressed Calibration Button Press the calibration CAL button to adjust the calibration value to reflect the known oxygen concentration T...

Page 8: ...his oxygen analyzer ideal for portable oxygen analysis by qualified heath care professionals 2 0 CALIBRATING THE Handi 2 1 Before You Begin A protective film covering the threaded sensor face must be...

Page 9: ...encing Calibration and Performance on page 5 of this manual Note We recommend use of medical grade USP or 99 purity oxygen when calibrating the Handi 2 3 In Line Calibration Configuration A 1 Put the...

Page 10: ...ess the CAL button on the Handi The calibration gas value on the analyzer display should read 20 9 or 100 depending on the gas stream used 3 0 OPERATING THE HANDI To Check the Oxygen Concentration of...

Page 11: ...e Handi will hold calibration and read correctly within 3 when in thermal equilibrium within the operating temperature range The device must be thermally stable when calibrated and allowed to thermall...

Page 12: ...an error code occurs E03 No valid calibration data available Make sure unit has reached thermal equilibrium Press and hold the Calibration Button for three seconds to manually force a new calibration...

Page 13: ...point on display located after the first digit Accuracy and Linearity 1 of full scale at constant temperature R H and pressure when calibrated at full scale Total Accuracy 3 actual oxygen level over...

Page 14: ...on Dioxide 10 2 Helium 70 2 8 0 HANDI SPARE PARTS AND ACCESSORIES 8 1 Standard Replacement Parts and Accessories Part Number Item R218M12 Operation Manual Handi R218M12 001 Operation Manual Handi Inte...

Page 15: ...calibration value Make sure that the calibration gas is connected to the Handi at 2 liters per minute for a minimum of 2 minutes prior to proceeding with calibration This 2 minute equilibration time...

Reviews: