Chapter 4 Specification
5-Installation Environment Requirements
1.The ambient air cleanliness grade requirement for optical fiber output head
installation: 1000 or more stringent grade. Suggestions for Configuration of
Standard Purification Workbench;
2.laser working environment temperature:10°C–40°C;
3.laser working environment humidity:10%-85%;
4.Avoid the condensation environment,the specific control standards are as
follows:
NOTE :
◎
In order to ensure a good operating environment of the laser, to reduce the
probability of failure due to condensation. We recommende to prepare an air-
conditioned room for the laser, so that the temperature in the air-conditioned room
is ≤ 30 ° C, and the relative humidity is ≤ 70%. The water cooler should be placed
in a different space from the laser. It is forbidden to place the water cooler in the air-
conditioned room;
◎
The laser head works at circulating temperature. In order to avoid condensation
on the laser head, it is necessary to adjust the temperature of the cooling water of
the external light path to room temperature. It is forbidden to cool the laser head with
low-temperature cooling water.