RF-CPIR-319-NN Rev.3 Oct. 2020 For updated Installation Manual Revision go to Maxouttech.com and select Documentation page.
3. Place the detector back in its location and walk the
coverage area verifying the LED lights when movement is
detected.
4. Walk test will time out after 1 min. of no motion
detection.
5. Remove the LED jumper
Note: Leaving the LED jumper installed will greatly reduce
the detectors battery life
Operation
3-minute lockout – to conserve battery life the detector has
a 3-minute lockout between motion detections
Unless the jumper is installed the red LED will not light
during motion detection.
Note: Leaving the LED jumper installed will greatly reduce
the detectors battery life.
Replacing the Batteries
Battery life depends on how often the detector transmits
signals, but is more dependent on the temperature of the
installation environment. When the battery voltage gets
low, the detector transmits a low battery signal to the
panel. The panel then activates trouble beeps to notify the
customer that the detector battery must be replaced.
Pressing the status button identifies the sensor with the low
battery.
Replace the battery immediately when this condition
occurs, using a
Panasonic CR123A 3V
. Note:
If a low
battery alarm occurs, replace the battery within 7 days.
CAUTION
:
Battery may explode if mistreated. Do not
recharge, disassemble or dispose of in fire.
Battery Disposal
The batteries used in this sensor are lithium batteries and
are not reusable. Properly dispose of used lithium batteries
according to your local hazardous waste disposal laws.
Specifications
Compatibility:
Interlogix 319.5 control panels, Qolsys
Power Source: 2 CR123A 3V Battery
Tamper Switch:
Sealed dome-contact
Sensitivity Selectable: 2 event or 3 event
Typical Battery Life: 4-6 years at 68°F
Transmitter Frequency: 319.5 MHz
Operating Temperature: -40 C - +55 C
Storage Temperature Range: -30° to 140° F (-34° to 60° C)
Maximum Humidity: 90% Relative Humidity non-condensing
Dimensions:
2.95in diameter X 1.39in depth
Housing:
High impact ABS
FCC / IC Statement
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of
the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This device complies with Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following two cond319ons: (1) this
device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of
the device.
Cet appareil est conforme avec Industrie Canada exempts de licence
standard RSS (s). Son fonctionnement est soumis aux deux cond319ons
suivantes: (1) cet appareil ne doit pas provoquer d'interférences et (2) cet
appareil doit accepter toute interférence, y compris celles pouvant causer
un mauvais fonctionnement de l'appareil.
In accordance with FCC requirements of human exposure to radio
frequency fields, the radiating element shall be installed such that a
minimum separation distance of 20 cm is maintained from the general
population.
FCC: 2ABBZ-RF-CPIR
IC: 11817A-RFCPIR
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. Changes or
modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
This Class B digital apparatus complies with Canadian ICES-3B.
Cet appareil numérique de la classe B est conforme à la norme NMB-003
du Canada.
MANUFACTURER HEREBY DISCLAIMS ALL WARRANTIES AND
REPRESENTATIONS, WHETHER EXPRESS, IMPLIED, STATUTORY
OR OTHERWISE INCLUDING (BUT NOT LIMITED TO) ANY
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE WITH RESPECT TO THESE PRODUCTS
AND ANY RELATED SOFTWARE. MANUFACTURER FURTHER
DISCLAIMS ANY OTHER IMPLIED WARRANTY UNDER THE
UNIFORM COMPUTER INFORMATION TRANSACTIONS ACT OR
SIMILAR LAW AS ENACTED BY ANY STATE.
(USA only) SOME STATES DO NOT ALLOW THE EXCLUSION OF
IMPLIED WARRANTIES, SO THE ABOVE EXCLUSION MAY NOT
APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL
RIGHTS AND YOU MAY ALSO HAVE OTHER LEGAL RIGHTS THAT
VARY FROM STATE TO STATE.
MANUFACTURER MAKES NO REPRESENTATION, WARRANTY,
COVENANT OR PROMISE THAT ITS ALARM PRODUCTS AND/OR
RELATED SOFTWARE (I) WILL NOT BE HACKED, COMPROMISED
AND/OR CIRCUMVENTED; (II) WILL PREVENT, OR PROVIDE
ADEQUATE WARNING OR PROTECTION FROM, BREAK-INS,
BURGLARY, ROBBERY, FIRE; OR (III) WILL WORK PROPERLY IN
ALL ENVIRONMENTS AND APPLICATIONS.