background image

 19

4.   It can no longer provide 1 hour of talk-time following a full charge (a battery will 

reach a near-full charge condition after AC power has been on for 24 hours 
continuously). 

 
5.  When it no longer can provide at least 16 hours of standby time following a full 

charge (a battery will reach a near-full charge condition after AC power has been on 
for 24 hours continuously). 

 

Battery Replacement 

 
1.  Before you begin, make sure that you have purchased a new battery. 
 
2.  Place the antenna down into the down position, or if you are using an external 

antenna, disconnect the antenna. 

 
3.  Disconnect the SAU-1900E’s AC power supply from the wall outlet, and then from 

the back/top of the SAU-1900E. 

 
4.  Disconnect all telephone lines that are plugged into the back/top of the SAU-1900E. 
 
5.  If you have installed your SAU-1900E using the desktop installation, skip to step 14.  

Otherwise, you will need a small, Phillips head screwdriver. 

 
6.  Place a soft cloth on a flat work surface, such as a table. 
 
7.  Holding onto the top of the SAU-1900E with one hand, push the bottom of the SAU-

1900E up gently until you feel it unlock. 

 
8.  Pull the SAU-1900E gently toward you.  It should come off the wall plate. 
 
9.  Unplug the short telephone cable that is plugged into the wall plate. 
 
10. Remove the short telephone cable from the bracket by pulling the cable through the 

small opening in the bracket between the prongs.  Save this cable, you will need it to 
reinstall the SAU-1900E. 

 
11. Place the SAU-1900E on the soft cloth, with the bracket side up and the screws 

toward you. 

 
12. Unscrew the screws that are holding the bracket in place. 
 
13. Move the end of the bracket where the screws were located up slightly, and then pull 

the bracket toward you to remove the bracket. 

 

Summary of Contents for SAU-1900E

Page 1: ...1900E 3 SERIAL NUMBER 4 SECURITY 5 SAFETY 5 Personal Safety 5 Dangerous Operating Environments 6 SAU 1900E INSTALLATION AND CONNECTION 7 Existing Telephone Service 7 Battery Installation 8 Battery Cha...

Page 2: ...t 2 M4x6mm self tapping Phillips head screws 6 8 20 3cm telephone cable for wall mounting 7 6 1 83m telephone cable for desktop use 8 This user s guide 9 Warranty card not shown If any parts are missi...

Page 3: ...aler where you purchased your SAU 1900E GETTING TO KNOW YOUR SAU 1900E 1 Antenna 2 Signal LED 3 AC Battery LED 4 Disruption LED 5 SIMM Card Cover not used at this time 6 Power connector 7 Two RJ 11 Mo...

Page 4: ...n the label attached to the back of the SAU 1900E on a label above a bar code see figure below An ideal time to record the serial number of your SAU 1900E would be when installing the SAU 1900E for th...

Page 5: ...are located Furthermore your SAU 1900E internally uses voltages currents that could pose possible electric shock hazards which could result in bodily injury For your safety do not attempt to open the...

Page 6: ...is could result in risk of fire or personal injury Dangerous Operating Environments IT IS RARE BUT YOUR SAU 1900E OR ATTACHED PHONES AND ACCESSORIES COULD GENERATE SPARKS THEREFORE YOU SHOULD NOT LOCA...

Page 7: ...E cannot be tied into lines that already have existing wire line or wireless telephone service If the SAU 1900E is tied into these existing telephone lines it will disrupt the SAU 1900E s capability o...

Page 8: ...d pushing the cover away from you It should move toward the edge opposite you Slide the cover completely out 5 Turn or rotate the battery so that the silver terminals on the battery will align with th...

Page 9: ...can supply a very large current more than 100 amps which create a large amount of heat resulting in burns smoke or even fire 2 DO NOT expose the battery to open flame 3 DO NOT disassemble the battery...

Page 10: ...to malfunction 7 Do not place the SAU 1900E where the temperature will be below 15 C 5 F or above 50 C 122 F Temperatures beyond these ranges could possibly damage the SAU 1900E 8 It is recommended no...

Page 11: ...rk in your house or business However it is possible that where the SAU 1900E is to be used another type of jack or even bare wire connections could be used instead If this is the case please contact t...

Page 12: ...lts or other such means of making an extremely secure attachment of the wall plate to the wall For this installation you will need a small Phillips head screwdriver 1 Place a soft cloth on a flat surf...

Page 13: ...t telephone cable through the small opening in the top of the bracket between the prongs Then pull the telephone cable through the rectangular opening in the middle of the bracket 7 Plug the end of th...

Page 14: ...unt Installation 3 Verify that the included antenna on the SAU 1900E is pointing up vertically If you are using an external antenna connect the antenna connector to the SAU 1900E 4 Connect the AC powe...

Page 15: ...in a few minutes of power up the SAU 1900E is properly connected and has detected the local network service provider You may begin making and receiving telephone calls 7 If you hear a BEEP BEEP BEEP E...

Page 16: ...ld possibly experience occasional dropouts in your conversation and even occasional dropped calls If you are using the included antenna and experience this condition frequently you may want to talk to...

Page 17: ...battery is powering the SAU 1900E but the SAU 1900E is still not working properly The disruption LED can indicate most but not all problems that could occur with the SAU 1900E Making Calls Making cal...

Page 18: ...your SAU 1900E THE BATTERY AND WHEN TO REPLACE IT Your SAU 1900E comes with a sealed lead acid battery for supplying backup power in the event of an outage or brownout of normal AC power Under normal...

Page 19: ...U 1900E 5 If you have installed your SAU 1900E using the desktop installation skip to step 14 Otherwise you will need a small Phillips head screwdriver 6 Place a soft cloth on a flat work surface such...

Page 20: ...If for some reason the battery strap is not available is damaged etc The battery can also be removed by turning the SAU 1900E over while holding your hand under the battery with the battery facing th...

Page 21: ...he wall outlet Then a soft cloth dampened not soaked with a mild soap water solution may be used Do not use any other chemicals on the SAU 1900E such as dust sprays cleaners etc These chemicals could...

Page 22: ...or is completely discharged Wait for electrical service to be restored Internal Battery Not Installed The SAU 1900E cannot operate without an internal battery during a power outage or without AC power...

Page 23: ...n 1 Antenna is not in the up vertical position 2 Antenna not connected 3 Move the SAU 1900E around to see if the LED stops blinking and turns on constantly i e try different locations in your house or...

Page 24: ...he same circuit Telephone cable defective Try a known good telephone cable Modular jack wired incorrectly Try plugging the telephone directly into the SAU 1900E You have the SAU 1900E plugged into a l...

Page 25: ...do not ring well Too many telephones connected to your SAU 1900E Add up the REN s on the back of each telephone connected to your SAU 1900E If this total number is greater than 4 0 you will have prob...

Page 26: ...you cannot place calls even though a dial tone is heard Pulse or rotary phone is being used to place a call The SAU 1900E will only accept tones from a touch tone compatible phone Make sure that the p...

Page 27: ...TIONS The following accessories options may be ordered from your dealer or service provider 1 Internal battery and battery strap Maxon xx 2 External antenna kit Maxon xx 3 MDL 1 Analog Fax Data Servic...

Page 28: ...5 hours or better with new fully charged battery 110 120V 60Hz AC Power Supply Requirements Maxon Model A51813D 19VDC 1 1A 220V 50Hz AC Power Supply Requirements Maxon Model A51909DG R 19VDC 0 9A 230...

Page 29: ...ned by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures n Re orient or relocate this equipment n Re orient or relocat...