TERMINAL “B”
BATTERY (+)
STARTER
SOLENOID
VALVE “C”
LOWERING
SOLENOID VALVE
TERMINAL “D”
COIL DRIVE
TERMINAL “C”
GROUND (-)
POWER UNIT
FIG. 28-1
TERMINAL “A”
LOAD
1.
Check if the
“A”
(lowering)
solenoid valve is constantly
energized. Connect voltmeter
negative (-) lead to ground (-)
wires connection on pump and
positive (+) lead to (+) terminal
on the
“A”
(lowering) solenoid
valve
(FIG. 28-1)
. If voltmeter
reads battery voltage, check
for faulty wiring or toggle
switch.
TROUBLESHOOTING
PLATFORM RAISES BUT LEAKS DOWN