Electrical Installation
Connections
IDX 56 User Manual
mmag | 2020-04 | rel9398
4-27
How to read pin assignment tables
• The first column describes both the pin number of the connector and of the matching prefab maxon
cable’s Head A.
• The second column describes the cable core color of the prefab maxon cable.
4.3.1
CAN IN (X1)
Figure 4-10
CAN IN connector X1
Table 4-10
CAN IN connector X1 – Specification
Table 4-11
CAN IN connector X1 – Pin assignment
For suitable prefab cable assemblies see
Table 4-12
CAN interface specification
CAN master settings and CAN bus termination
• Consider the CAN master’s maximal bit rate.
• The standard bit rate setting (factory setting) is 1 Mbit/s.
• Use 120
Ω
termination resistor at both ends of the CAN bus.
• For detailed information see
separate document «IDX Communication Guide».
CAN IN connector X1
Type
M8, male, 5 poles, B-coded
X1
Head A
Prefab
cable
Signal
Description
Pin
Color
1
red
CAN_V+
CAN external supply
2
—
CAN_SHLD
Shield
3
white
CAN_H
CAN high bus line
4
blue
CAN_L
CAN low bus line
5
black
CAN_GND
Ground
CAN interface
Standard
ISO 11898-2:2003
Max. bit rate
1 Mbit/s
Max. number of CAN nodes
127 (via software setting)
Protocol
CiA 301 version 4.2.0
Node-ID setting
By software