11921
Slauson
A
ve.
Santa
Fe
Springs,
CA.
90670
(800)
227-41
16
F
AX
(888)
771-7713
15
7.
Bolt cover on the main housing
as shown in
FIG. 15-3
. Torque
the 5/16”-18 cover bolts from
10 to 14 lb-ft
.
CAUTION
Main housing cover must be
correctly secured to prevent it
from becoming a hazard.
POWER UNIT
(MANUAL CLOSE POWER UNIT SHOWN)
FIG. 15-2
POWER UNIT
(REF)
RESERVOIR
5.
Raise platform to bed height
(FIG. 15-1)
.
Continue to hold
UP/DOWN
control
switch for 30 - 60 seconds to circulate
hydraulic fl uid through slave cylinder
and reservoir
(FIG. 15-2)
. Release
UP/
DOWN
control switch.
PLATFORM AT BED HEIGHT
FIG. 15-1
NOTE:
One cycle of draining, fi lling,
and circulating hydraulic fl uid
should be enough to fi ll the sys-
tem with new hydraulic fl uid.
6.
Lower platform to the
ground
(FIG. 15-3)
.
BOLTING ON COVER
FIG. 15-3
UP/DOWN
CONTROL
SWITCH
BOLT,
LOCK WASHER &
FLAT WASHER
(3 PLACES)
COVER
Summary of Contents for DMD series
Page 1: ...M 16 40 REV C SEPTEMBER 2022 MAXON Lift Corp 2022...
Page 2: ......
Page 5: ...DMD ELECTRICAL VALUES TORQUE SPECIFICATIONS 49 BOLT TORQUES 50...
Page 51: ......