1.
Stow platform
(FIG. 25-1)
. Refer
to
Operation Manual
for detailed
operating instructions.
Ensure platform is latched securely in stowed
position to release most tension from torsion
bar(s) and keep platform from suddenly un-
folding. Injury could result from unbolting the
torsion bar(s) under tension. When all tension
is released from torsion bar(s), platform can
unfold suddenly. Any person in the path of
opening platform could be injured.
WARNING
!
FIG. 25-1
2.
Remove torsion bar cover from platform
(FIG. 25-2)
.
REMOVING TORSION BAR COVER
FIG. 25-2
PLATFORM
COVER
TAPPING
SCREWS
(8 PLACES)
REPLACE LH TORSION BAR
PLATFORM
LATCH
TORSION BAR REPLACEMENT