LIQUID SEALANT APPLICATION
Clean all threads with a soft brush and a suitable cleaning solvent.
Dry threads thoroughly with compressed air or shop towel.
Apply the Liquid Sealant (Compound PLS 2), to the external threads of
the Male Connector.
Assemble the fitting and torque it to the prescribed value.
Check for leakage. If leakage exists, remove the fitting and return to
Step # 1.
If fitting is loosened or removed, return to Step # 1.
1.
2.
3.
4.
5.
6.
P/N 260798-02
CAUTION
Due to the 80% lead content in PLS 2, follow these safety and first aid
precautions:
Eye Contact
- Flush eyes immediately with large quantities of water,
lifting the upper and lower eyelids occasionally. If irritation persists, con-
sult a physician.
Skin Contact
- Flush the contaminated skin and wash with soap and
water.
Ingestion
- If person is conscious, give large quantities of water to drink
and induce vomiting. Consult a physician immediately.