PLATFORM WILL NOT LOWER
1.
Check the Battery Cables for damage, and the Battery for a charge.
Replace or recharge as needed. The use of a Voltage Load Tester is
recommended.
2.
Check the following Solenoids for power: the two “D”
Solenoid Valve Coils (located at the top of each Column),
the “M” Motor Solenoid Valves, and the “4-Way” Solenoid
Valves (located in the Pump Box).
VALVE
COIL
VALVE CARTRIDGE
SOLENOID
“D”
3.
To clean the Valve, remove the Valve Coil
from the Valve Cartridge. Using a paper clip,
push on the Plunger inside the Valve
Cartridge. It should move freely approximately
1/8”. Inspect O-Ring and wash the Cartridge in
solvent to remove any foreign substances
inside the Cartridge. If Plunger still does not
move freely (approx. 1/8”), then replace the
Valve Cartridge.
4-WAY
SOLENOID “F”
F
OLD STYLE PUMP
SOLENOID
“M”
4-WAY
SOLENOID “C”
NEW STYLE PUMP