Maxon 7840 Manual Download Page 8

 

Licensing and Service Information

 

 

FCC Licensing 
 

The Federal Communications Commission requires that the operator of this radio be properly 
licensed under the applicable Part and/or Parts of the FCC Rules and Regulations. 
 
Consult with your Maxon Dealer, or contact the nearest FCC Field Office for information about 
obtaining a license. 
 

Service 
 

Do not tamper with internal adjustments. Damage to the equipment and/or improper operation 
may result. There are no user serviceable items inside the radio. 
 
It is recommended that you return your radio to a qualified Maxon Dealer for any service or 
repairs. 
 

Recycling/Disposal of Batteries

 

 
The U.S. Environmental Protection Agency (EPA) classifies used Ni-MH batteries as hazardous 
waste, unless certain exemptions apply. 
 
The battery should be recycled at the end of its useful life. Under various state or local laws, such 
batteries must be recycled or disposed of properly and cannot be dumped in landfills or 
incinerators. 
 
Maxon America, Inc. fully endorses and encourages the recycling of Ni-MH batteries. A national 
program to collect and recycle used Ni-MH batteries is being implemented by the Rechargeable 
Battery Recycling Corporation (RBRC Ö). This program is being funded through the use of 
license fees paid by the battery and product manufacturers to place the RBRCÖ Seal on the 
batteries. 
 
The following is a list of facilities where the batteries can be shipped to be recycled. Contact 
these facilities for proper packaging and shipping guidelines. 

 
Software Copyrights 
 

The Maxon products described in this operating instruction manual may include copyrighted 
Maxon software programs stored in semi-conductor memories or other media. Laws in the United 
States and other countries preserve for Maxon certain exclusive rights for copy-righted software 
programs, including the exclusive right to copy or reproduce in any form the copyrighted software 
program. Accordingly, the copyrighted Maxon software programs contained in the Maxon 
products described in this operating instruction manual may not be copied or reproduced without 
the express written permission of Maxon. Furthermore, the purchase of Maxon products shall not 
be deemed to grant either directly or by implication, estoppel, or otherwise, any license under the 
copyrights, patents or patent applications of Maxon, except for normal non-exclusive royalty free 
license to use that arises by operation of law in the sale of a product. 

 
Maintenance 

 
Your SP-0402 Radio is designed to be maintenance free. To keep your radio in good working 
condition: 
 

Summary of Contents for 7840

Page 1: ...1 SP 0402 Synthesized Scanning Radio MAXON CIC ...

Page 2: ... transmit by pressing the PTT bar on the radio These are required operating configurations for meeting FCC RF exposure compliance Failure to observe these restrictions mean violation Safety Information The Federal Communications Commission FCC with its action in General Docket 79 144 March 13 1985 has adopted a safety standard for human exposure to Radio Frequency RF electromagnetic energy emitted...

Page 3: ...e consult your Maxon Dealer SP 0402 Specification MODEL SP 0402 MODEL CODE 7840 EQUIPMENT TYPE Hand portable PERFORMANCE SPECIFICATIONS TIA EIA 603 BAND UHF2 440 470Mhz CHANNEL SPACINGS 12 5KHz 25KHz PROGRAMMBLE RF OUTPUT POWER 5 1 WATT MODULATION TYPE F3E AUDIO POWER 500mW EXT WITH 8 OHM 1W INT WITH 4 OHM INTERMEDIATE FREQUENCY 45 1MHz 455KHz CHANNELS 16 Channel FREQUENCY SOURCE SYNTHESIZER POWER...

Page 4: ...r EXT Jack 12 Belt Clip 13 Battery 14 Battery Charge Contacts 15 Speaker Antenna Installation Fasten the antenna to the radio by turning the antenna clockwise into the receptacle on top of the radio Installing and Removing the Battery Pack To Install Position the guides of the battery in line with the radio battery guide rails and slide the battery into position until a click is heard To Remove Ho...

Page 5: ...r up a quick melody indicates that the self test of the microprocessor functions has been completed satisfactorily A series of tones may be sounded with any of the following conditions Attempt to transmit on a channel set for receive only Attempt to transmit on a channel that is already in use when busy channel lockout has been programmed into the radio Transmitting time has exceeded time out time...

Page 6: ...ning Frequencies and functions can be programmed from radio to radio by using a cloning cable Password Password function is the function that the user knows the password can use the radio You can set password enable and the password code at pc program And you can set password enable disable by programmable key password and menu option At this time you can enter the password code by using EMG PTT M...

Page 7: ...7 Short pressing scan operaiting Look Back channel edit Tx power H L EMG Transmit EMG ID 5 times and generate warning audio alert during 7secs ...

Page 8: ...poration RBRC Ö This program is being funded through the use of license fees paid by the battery and product manufacturers to place the RBRCÖ Seal on the batteries The following is a list of facilities where the batteries can be shipped to be recycled Contact these facilities for proper packaging and shipping guidelines Software Copyrights The Maxon products described in this operating instruction...

Page 9: ...f the user improper or unauthorized alterations repairs to the Product use of the Product in a manner for which it was not designed or by causes external to the Product This warranty is void if the serial number is altered defaced or removed Maxon s sole obligation hereunder shall be to repair or replace the Product covered in the above warranty THE EXPRESS WARRANTIES CONTAINED HEREIN ARE IN LIEU ...

Reviews: