Maxkon STAR 2000 Installation & Operating Instructions Manual Download Page 4

MOUNTING POSITION:

 

Diagram 1: STAR heated area and applications 

 

 

 

      Heating area 18m²-21m²

 
 

Mediumwave 

Infrared 

heat is characterised by a 
strong  central  beam  that 
dissipates  to  a  gentler 
intensity 

heated 

area 

outside the central beam. 

The zone heated by STAR will 
increase in size the higher 
the heater is installed from 
the  floor,  but  the  warmth 
experienced 

from 

the 

heater will be lower. 

The  mounting  height  and 
intensity  should  reflect 
the  intended  use  of  the 
heater. 

Mount  the  heater  at  a 
lower  height  in  areas 
intended  for  low  physical 
activity  (for  example  a 
seating  area)  or  areas 
subject to stronger airflow 
(outside  or  near  open 
doors). 

Mount STAR higher where 
less  intense  warmth  is 
needed 

(for 

example 

warehouses where workers 
are  active  or  wear  warm 
clothing). 

For  permanent  installation 
(i.e. not using a stand), the 
STAR  must  be  located  in  a 
position  to  allow  proper 
and efficient use but one 
that ensures hot parts are 
not  touched  accidental

 

The recommended installation height of the STAR  is 2.4m to 3.5m (95”-138”) from the floor. 

IMPORTANT: DO not mount STAR below 2.4m if any kind of automated on/off controller is to be used 

Under no circumstances is the  STAR  to be installed at less than 1.8m (71”) from the floor. Consideration should be 
given to any temporary or occasional additions such as stages or platforms and adjusted accordingly. For outdoor 
use, or other areas with air movement/wind the directional Infrared spread may reduce by 1/3 to 1/2. 

Wall/ceiling mount swivel brackets are provided with the heater which has been specifically designed to allow this 
product to be fitted to a wall or ceiling with adequate clearances at the back of the unit. Do not mount the heater 
with any other bracket except those provided. The sides and ends of the heater must always be at least 500mm 
(19.6”) away from the nearest wall, ceiling or other structure. 