Maxkon STAR 2000 Installation & Operating Instructions Manual Download Page 3

SAVE THESE INSTRUCTIONS. 

 

WATER INGRESS PROTECTION:

 

STAR is rated to a standard IP55 enabling it to be mounted outdoors and exposed to occasional rainfall. To prolong 
the life of the heater we recommend installing it where it will be sheltered from the effects of weather. The 
heater is not intended for installation in locations that are permanently wet or humid. 

 

Installation in potentially wet or humid rooms such as bathrooms must be carried out by a suitably qualified 
installer and comply with local electrical safety requirements. Installation must be such that: 

 

the heater must not be able to become detached from the fittings and fall into a bathtub, shower, 
swimming pool or other water container; 

 

Switches and other controls cannot be touched by a person in a bath or shower. 

 

If in doubt, do not install. AUSWAY PACIFIC PTY LTD  shall not be liable for any loss, damage or injury caused 
or resulting from inadequate fitting or incorrect placement of heaters close to water sources. 

 
 

ELECTRICAL INFORMATION:

 

Installation must only be carried out by competent persons or a qualified electrician according to national 
regulations.  
 

 

Table 1. Electrical Specification 

Model 

Rated Power 

Voltage 

Current 

Frequency 

Fuse (Minimum) 

STAR 2000 

2000W 

220-
240V 

8.7A 

50/60Hz 

13A 

STAR 2500 

2500W 

220-
240V 

10.9A 

50/60Hz 

13A 

STAR 3000 

3000W 

220-
240V 

13A 

50/60Hz 

13A 