Maximum Controls MAX Ultra Arm Manual Download Page 9

MAX SOLAR CONTROL BOX

Two 12V 18 AH 

(AGM Rechargable Batteries) 

UL Reset Button

Jog Switch

OPTIONAL

30A

FUSE

Loop Rack

OPTIONAL

Steel housing

2-layer  protection  

Gold zinc 

Electrostatic 

powder coating 

Gold plated 

automobile connectors

through the system

SOLAR MODE

Switch to enable 

low power draw 

for solar mode

Control Panel

Solar Regulator

24V, 10A

(MORNING STAR)

Solar Regulator
24V, 10A
(MORNING STAR)

24V Solar Panel
Output: 36 V (Max) - 
Open Circuit

Wire solar panel terminals to 
solar regulator input
Caution: polarity matters

EXIT PWR

ALARM

POWER /

SOLAR IN

BATTERY

INPUT

OPENING

CLOSING

MOTOR 2

MOTOR 1

ERD

OBD PORT

BLACK BOX

PROGRAMMING

SOLAR MODE

MOTOR

OVER

LOAD

ERD
MOTOR

OVER

LOAD

MIN

MAX

OFF

MAX

SENSE

MAX

SENSE

BATTERY

BACKUP MODE

ERD SENSITIVITY

MOTION CONTROL

OPEN

CLOSING GATE SPEED

MOTOR 2

LIMITS

MAG

LOCK

UL

ENTRAP

STOP

CLOSE

CLOSE

TIMER

MAGLOCK

DELAY

JOG

BATTERY

TEST

BATTERY

INPUT

ERROR

BATTERY

IN USE

POWER

REPLACE

BATTERY

LEAVE

CLOSED

LEAVE

OPEN

OPEN

1 TIME

BATTERY VOLTAGE

F

1/2

E

RESET

ID

PLUG

MODULE

PORT

GATE OPEN

GND

OPEN ONLY NC

OPEN ONLY 10K

PHOTO CLS NC

OPEN / CLS NC

GND

12VDC OUT

GND

GND

GND

GND

GND

JOG CLOSE

JOG OPEN

TAMPER IN

TAMPER NO

GATE DISABLE

KEYPAD/CARD

GND

GND

MAX OPEN

FIRE DEPT

RADIO GND

RADIO SIGNAL

STRIKE

CLOSE COM

COM

STOP

OPEN

CLS ONLY 10K

OPEN / CLS 10K

12VDC OUT

NO

COM

NC

COM

GATE CLOSED

LIMIT 1

GND

LIMIT 2

MOTOR 1

LIMITS

MOTOR 1

MOTOR 2

LIMIT 1

GND

LIMIT 2

LIMIT 1

LIMIT 2

LIMIT 1

LIMIT 2

ID PLUG

ERROR

24VDC OUTPUT

12VDC OUTPUT

GND

GND

GND

LOOP

LOOP PWR

LOOP

CENTER

SAFETY

OFF

SINGLE

OPEN

ON/OFF

BATTERY

CLOSE

DUAL

ON

ANTI-

TAILGATE

PUSH

OPEN

PULL

OPEN

GATE

OFF

1

2

3

4

5

6

7

8

9

10

OFF

1

2

3

4

5

6

MIN

MIN

MAX

MAX

ON

OFF

2.5 sec

1.5 sec

FAULTS

OPERATOR

OFF

EXIT LOOP

16

MIN

16

MIN

3

1

14

12

9

7

3

1

14

12

9

7

UL SENSOR 10

K

UL SENSOR N.C.

MODE 

A

MODE B

PROGRAM

MOTOR 1

INPUTS

[

+

]

[

-

]

[

+

]

[

-

]

MOTOR 2

INPUTS

MAXIMUM CONTROLS

DSP ARM CONTROLLER

Maximum Controls LLC. • 949.699.0220 • 10530 Lawson River Ave, Fountain Valley, CA 92708

MAX ACTUATOR CONTROL BOX 

Solar Application Guide/Wiring

www.max.us.com

Rev April25

LOAD

BATTERY

SOLAR

+

-

+

-

+

-

Solar Regulator Terminal

Enclosure

NOTE:

 Cover solar panel 

from sunlight 

BEFORE

 wiring 

to prevent a shock from 

occurring.

NOTE:

 For more 

information about solar 

panel wiring, see 

your 

chosen

 panel’s manual.

Use insulated tools and avoid 

placing metal objects near the 

batteries.

Suggested Solar Regulators:

Morning Star SunSaver OR Morning Star SunSaver MPPT  

Pos + Red

Neg - Black

Polarity Matters!

12 Volt

Batteries wired in series

12 Volt

Batteries should be in a

well ventilated enclosure

or overheating will occur

and reduce battery life.

DANGER

HAZARDOUS CURRENT

NEVER touch

positive and

negative battery

cables together!

Solar Panel

Connect 

solar panel

to regulator

3

Connect batteries to regulator

4

Connect solar regulator to

Power/ Solar IN DSP ARM

CONTROLER

5

Install components in water resistant 

well ventilated enclosure.
Properly Ground Enclosure.

Two 12 V Batteries (24V)

Use AGM battery type.

POWER/
SOLAR IN

9

7

Pos + Red

Neg - Black

ON and OFF 

Power Supply Switch 

Summary of Contents for MAX Ultra Arm

Page 1: ...ODS GATE GATE RELEASE UL 2018 THE NEW STANDARD Heavy Duty 24 Volt DC Linear Actuator for Residential Light Commercial use Super quiet With Built in limit switches Large diameter stainless steel output shaft DSP Control Optional Max App 2 Year Warranty or 100 000 Cycles whichever comes first MAX AC control box ...

Page 2: ...on against fire replace only with the same type and rating of fuse AVERTISSEMENT pour ne pas compromettre la protection contre les risques d incendie utiliser un fusible de mêmes type et caractéristiques nominales Select Input Voltage 115VAC or 230VAC AC POWER IN 115V SAFETY CENTER EXIT J3 J2 J4 J5 EXIT PWR ALARM POWER SOLAR IN BATTERY INPUT OPENING CLOSING MOTOR 2 MOTOR 1 ERD OBD PORT BLACK BOX P...

Page 3: ... function Advanced anti tailgate feature prevents unwanted intrusion Unique to Max Ultra Arm SAFETY SPECIFICA TIONS UL 325 991 compliant Class I II III and IV CSA approved Built in advanced entrapment protection and alarm output Built in gate in motion alarm for industrial applications Robust lightning protection up to 20K Volts and 10K Amps on all inputs and outputs 35 channels including loop det...

Page 4: ... for vehicles only Pedestrians must use separate entrance Sa fety Loop c l o s e o p e n JOG GATE OPEN CLOSE RESET ALARM Moving Gate Can Cause Seriou s Injury or Death CLEAR Gate may move at any time without prior warning t let children operate the gate or play gate area This entrance is for vehicles only Pedestrians must use separate entrance Sa fety Loop c l o s e o p e n JOG GATE OPEN CLOSE RES...

Page 5: ...ch Limit Switch Limit Switch Two Limits Switch System Easy mechanical release with the key Limit Cover Limit Cap MUST be ON Remove limit cap with 2 screws and slide limit cover off operator Loosen adjustment screws on limit switches and slide switches until approprate Limit LEDs lights up Tighten limit screws when finished Adjust Slow Down switches to your personal preference Cycle operator OPEN a...

Page 6: ...ic installations the two independent closing speeds can be adjusted to achieve a smooth closing sync Whichever gate closes first slow it down This enables the installer to visually sync the closing cycle This feature is unique to Maximum Control s actuators with the independent closing speeds adjusted the closing gate leaves can be synced ...

Page 7: ... that is gold zinc plated and powder coated Each AC Control Box comes with an exterior UL reset button a convenient jog key switch for emergency access or egress a 10 amp power supply with two 115 VAC accessory outlets two 7 amp batteries conveniently located behind the control panel a loop rack and much more A lockable steel cover finishes off this slick design A convenient LCD display keeps you ...

Page 8: ...ery Backup Mode Switch 2 Battery Test Switch 3 ERD Sensitivity 4 OBD Port 5 DIP Switches 6 Program Button 7 Loop Status 8 Solar Mode Application 9 Motion Control Buttons 10 Maglock Delay 11 LCD Display 12 Close Timer Switch 13 Jog Open Close 14 Closing Gate Speed 8 7 6 5 3 4 2 1 CONTROL FEA TURES AND CONNECTIONS 1 2 11 3 4 5 6 7 8 9 12 10 14 13 8 ...

Page 9: ... STAR Solar Regulator 24V 10A MORNING STAR 24V Solar Panel Output 36 V Max Open Circuit Wire solar panel terminals to solar regulator input Caution polarity matters MAX ACTUATOR CONTROL B Solar Application Guide W LOAD BATTERY SOLAR Solar Regulator Terminal NOTE Cover solar panel from sunlight BEFORE wiring to prevent a shock from occurring NOTE For more information about solar panel wiring see yo...

Page 10: ...xit RTE port Each port has indicator LEDs for troubleshooting Rotary switch to select device ID of keypad Max Cell Hub provides cell connectivity to all Max PRO series pad mt operators and MAX linear actuators for app control AT T or Verizon cell data service To activate a sim card on our portal simply choose data plan and credit card info Has RS485 comm port supports up to16 MAX Keypads card read...

Page 11: ...ion mismatch e Damages due to vandalism Section III RMA Shipping Policy a Maximum Controls LLC will pay for return shipping via standard ground UPS or USPS FOB CA on all RMA s within one year of Distributor s purchase b Any form of Expedited Shipping on any RMA will be paid by Distributor Section IV Product Returns a Products must be in original resalable condition with all warranty information ma...

Page 12: ...ra Arm protects all peripheral inputs loop inputs power inputs relay outputs and all communication lines over 35 channels of protection in 1 1 000 000 000 of a second With special emphasis on power supply protection the Max Ultra Arm is guaranteed to withstand any lightning hit more than 50 feet away Truly protected like no other operator in the world ...

Page 13: ...C 949 699 0220 10530 Lawson River Ave Fountain Valley CA 92708 USA Independent Dealer or Distributor Maximum Controls LLC 949 699 0220 10530 Lawson River Ave Fountain Valley CA 92708 USA Independent Dealer or Distributor www Max US com ...

Reviews: