MECHANICAL SPECIFICATIONS 

MAX ULTRA ARM 

FEATURE LIST:

Gate Capacity

•  Shipping weight of Actuator: Max Ultra Arm (27 lbs)

•  Shipping weight of AC Control Box (38 lbs)

•  Stainless steel output shaft 2” tubular

•  Direct gear drive (no internal chains, belts, or pulleys)

•  Mechanical and electrical gate release functions

•  Corrosion protection: powder coated alumminum housing

•  Continue cycles at extreme temperature ranges. No overheating

•  Limit Switch base Intelligent ramp-up and ramp-down for smooth gate operation

   

=

 

Unique to Max Ultra Arm

ELECTRICAL SPECIFICATIONS

•  24 Volt DC motor 

•  Two independently adjustable closing speed controls with 16 positions each

•  Switchable 115/230 voltage selection

•  Adaptive DSP motor control for advanced motion control 

•  Real time performance analyzer and event log (OBD PORT and Black Box)

•  Magic Box enables low voltage wiring capabilities for remote power up to 1000 ft 

•  On-board switch for solar mode enables 5 milliamp idle in sleep mode

•  Gold contact input connections and automobile grade connectors

•  -4F? to 165F? (-20C to +74C) operational range including battery backup without a heater

specifications

control box

13.5”

5.75”

17”

JOG GATE

OPEN / CLOSE

RESET ALARM

115VAC

3A max

7A

FUSE

POWER

On

Off

WARNING:

 For continued protection 

against fire, replace only with the 

same type and rating of fuse.

AVERTISSEMENT:

 pour ne pas compromettre la 

protection contre les risques d’incendie, utiliser un 

fusible de mêmes type et caractéristiques nominales.

Select Input Voltage

115VAC or 230VAC  

(AC)

POWER IN

115V

SAFETY

CENTER

EXIT

J3

J2

J4

J5

EXIT PWR

ALARM

POWER /

SOLAR IN

BATTERY

INPUT

OPENING

CLOSING

MOTOR 2

MOTOR 1

ERD

OBD PORT

BLACK BOX

PROGRAMMING

SOLAR MODE

MOTOR

OVER

LOAD

ERD
MOTOR

OVER

LOAD

MIN

MAX

OFF

MAX

SENSE

MAX

SENSE

BATTERY

BACKUP MODE

ERD SENSITIVITY

MOTION CONTROL

OPEN

CLOSING GATE SPEED

MOTOR 2

LIMITS

MAG

LOCK

UL

ENTRAP

STOP

CLOSE

CLOSE

TIMER

MAGLOCK

DELAY

JOG

BATTERY

TEST

BATTERY

INPUT

ERROR

BATTERY

IN USE

POWER

REPLACE

BATTERY

LEAVE

CLOSED

LEAVE

OPEN

OPEN

1 TIME

BATTERY VOLTAGE

E

F

1/2

RESET

ID

PLUG

MODULE

PORT

GATE OPEN

GND

OPEN ONLY NC

OPEN ONLY 10K

PHOTO CLS NC
OPEN / CLS NC

GND

12VDC OUT

GND

GND

GND

GND

GND

JO

CL

OS

E

JO

OP

EN

TAMPER IN

TAMPER NO

GATE DISABLE

KEYPAD/CARD

GND

GND

MAX OPEN

FIRE DEPT

RADIO GND

RADIO SIGNAL

STRIKE

CLOSE COM

COM

STOP

OPEN

CLS ONLY 10K

OPEN / CLS 10K

12VDC OUT

NO

COM

NC

COM

GATE CLOSED

LIMIT 1

GND

LIMIT 2

MOTOR 1

LIMITS

MOTOR 1

MOTOR 2

LIMIT 1

GND

LIMIT 2

LIMIT 1

LIMIT 2

LIMIT 1

LIMIT 2

ID PLUG

ERROR

24VDC OUTPUT

12VDC OUTPUT

GND

GND

GND

LOOP

LOOP PWR

LOOP

CENTER

SAFETY

OFF

SINGLE

OPEN

ON/OFF

BATTERY

CLOSE

DUAL

ON

ANTI-

TAILGATE

PUSH

OPEN

PULL

OPEN

GATE

OFF

1

2

3

4

5

6

7

8

9

10

OFF

1

2

3

4

5

6

MIN

MIN

MAX

MAX

ON

OFF

2.5 sec

1.5 sec

FAULTS

OPERATOR

DSP ARM CONTROLLER

OFF

EXIT LOOP

16

MIN

16

MIN

3

1

14

12

9

7

3

1

14

12

9

7

UL SENSOR 10

K

UL SENSOR N.C.

MODE 

A

MODE B

PROGRAM

MOTOR 1

INPUTS

[

+

]

[

-

]

[

+

]

[

-

]

MOTOR 2

INPUTS

MAXIMUM CONTROLS

DSP ARM CONTROLLER

Class of operation

.....UL 325 Class I, II, III, IV

Type of gate

.....Vehicular swing gate only

Input AC power/amps

.....

Switchable: 115VAC / 6 amp, 1 phase

       

OR

     

 

230VAC / 2 amp, 1 phase

Power output

.....24 VDC

Operating temperature

.....-4°F to 158°F (-20°C to 70°C)

Cycles per hour AC input power

.....Continuous

Battery back-up cycles

.....

(7 Amp/Hr batteries fully charged).....Approx 450 cycles

Entrapment protection

.....

  - UL 325 Type A Inherent (ERD sensor)
  - Inputs for 

NORMALLY CLOSED (N.C.) or 10K 

Type

    UL 325 Type B1 (photo cell) and Type B2 (sensing edge)

   

MONITORED

 when used.

max ultra arm

Min = 39.1” (993.5 mm)

Power supply

.....24 VDC

Max Stroke length

.....21.2 in (540 mm)

Nominal thrust

.....5500 N

Maximum operating current

.....6A for max 10 sec

Max gate weight per leaf

.....1200 lbs (550 kg)

Max gate length per leaf

.....157.4 in (4 m)

Operating Temperatures

.....-20°C ~+50°C

Max = 60.3” (+/-.39“) (1531 mm (+/- 10 mm)

7.35”

186mm

5.07”

128mm

5”

127mm

8ft

12ft

16ft

18ft

Max Gate

Weight/Length

1600 lbs

725 kg

1200 lbs

544 kg

800 lbs

362 kg

600 lbs

272 kg

2

MAX Ultra Arm V1

specifications

control box

13.5”

5.75”

17”

JOG GATE

OPEN / CLOSE

RESET ALARM

115VAC

3A max

7A

FUSE

POWER

On

Off

WARNING:

 For continued protection 

against fire, replace only with the 

same type and rating of fuse.

AVERTISSEMENT:

 pour ne pas compromettre la 

protection contre les risques d’incendie, utiliser un 

fusible de mêmes type et caractéristiques nominales.

Select Input Voltage

115VAC or 230VAC  

(AC)

POWER IN

115V

SAFETY

CENTER

EXIT

J3

J2

J4

J5

EXIT PWR

ALARM

POWER /

SOLAR IN

BATTERY

INPUT

OPENING

CLOSING

MOTOR 2

MOTOR 1

ERD

OBD PORT

BLACK BOX

PROGRAMMING

SOLAR MODE

MOTOR

OVER

LOAD

ERD

MOTOR

OVER

LOAD

MIN

MAX

OFF

MAX

SENSE

MAX

SENSE

BATTERY

BACKUP MODE

ERD SENSITIVITY

MOTION CONTROL

OPEN

CLOSING GATE SPEED

MOTOR 2

LIMITS

MAG

LOCK

UL

ENTRAP

STOP

CLOSE

CLOSE

TIMER

MAGLOCK

DELAY

JOG

BATTERY

TEST

BATTERY

INPUT

ERROR

BATTERY

IN USE

POWER

REPLACE

BATTERY

LEAVE

CLOSED

LEAVE

OPEN

OPEN

1 TIME

BATTERY VOLTAGE

E

F

1/2

RESET

ID

PLUG

MODULE

PORT

GATE OPEN

GND

OPEN ONLY NC

OPEN ONLY 10K

PHOTO CLS NC
OPEN / CLS NC

GND

12VDC OUT

GND

GND

GND

GND

GND

JO

CL

OS

E

JO

OP

EN

TAMPER IN

TAMPER NO

GATE DISABLE

KEYPAD/CARD

GND

GND

MAX OPEN

FIRE DEPT

RADIO GND

RADIO SIGNAL

STRIKE

CLOSE COM

COM

STOP

OPEN

CLS ONLY 10K

OPEN / CLS 10K

12VDC OUT

NO

COM

NC

COM

GATE CLOSED

LIMIT 1

GND

LIMIT 2

MOTOR 1

LIMITS

MOTOR 1

MOTOR 2

LIMIT 1

GND

LIMIT 2

LIMIT 1

LIMIT 2

LIMIT 1

LIMIT 2

ID PLUG

ERROR

24VDC OUTPUT

12VDC OUTPUT

GND

GND

GND

LOOP

LOOP PWR

LOOP

CENTER

SAFETY

OFF

SINGLE

OPEN

ON/OFF

BATTERY

CLOSE

DUAL

ON

ANTI-

TAILGATE

PUSH

OPEN

PULL

OPEN

GATE

OFF

1

2

3

4

5

6

7

8

9

10

OFF

1

2

3

4

5

6

MIN

MIN

MAX

MAX

ON

OFF

2.5 sec

1.5 sec

FAULTS

OPERATOR

DSP ARM CONTROLLER

OFF

EXIT LOOP

16

MIN

16

MIN

3

1

14

12

9

7

3

1

14

12

9

7

UL SENSOR 10

K

UL SENSOR N.C.

MODE 

A

MODE B

PROGRAM

MOTOR 1

INPUTS

[

+

]

[

-

]

[

+

]

[

-

]

MOTOR 2

INPUTS

MAXIMUM CONTROLS

DSP ARM CONTROLLER

Class of operation

.....UL 325 Class I, II, III, IV

Type of gate

.....Vehicular swing gate only

Input AC power/amps

.....

Switchable: 115VAC / 6 amp, 1 phase

       

OR

     

 

230VAC / 2 amp, 1 phase

Power output

.....24 VDC

Operating temperature

.....-4°F to 158°F (-20°C to 70°C)

Cycles per hour AC input power

.....Continuous

Battery back-up cycles

.....

(7 Amp/Hr batteries fully charged).....Approx 450 cycles

Entrapment protection

.....

  - UL 325 Type A Inherent (ERD sensor)
  - Inputs for 

NORMALLY CLOSED (N.C.) or 10K 

Type

    UL 325 Type B1 (photo cell) and Type B2 (sensing edge)

   

MONITORED

 when used.

max ultra arm

Min = 39.1” (993.5 mm)

Power supply

.....24 VDC

Max Stroke length

.....21.2 in (540 mm)

Nominal thrust

.....5500 N

Maximum operating current

.....6A for max 10 sec

Max gate weight per leaf

.....1200 lbs (550 kg)

Max gate length per leaf

.....157.4 in (4 m)

Operating Temperatures

.....-20°C ~+50°C

Max = 60.3” (+/-.39“) (1531 mm (+/- 10 mm)

7.35”

186mm

5.07”

128mm

5”

127mm

8ft

12ft

16ft

18ft

Max Gate

Weight/Length

1600 lbs

725 kg

1200 lbs

544 kg

800 lbs

362 kg

600 lbs

272 kg

2

MAX Ultra Arm V1

specifications

control box

13.5”

5.75”

17”

JOG GATE

OPEN / CLOSE

RESET ALARM

115VAC

3A max

7A

FUSE

POWER

On

Off

WARNING:

 For continued protection 

against fire, replace only with the 

same type and rating of fuse.

AVERTISSEMENT:

 pour ne pas compromettre la 

protection contre les risques d’incendie, utiliser un 

fusible de mêmes type et caractéristiques nominales.

Select Input Voltage

115VAC or 230VAC  

(AC)

POWER IN

115V

SAFETY

CENTER

EXIT

J3

J2

J4

J5

EXIT PWR

ALARM

POWER /

SOLAR IN

BATTERY

INPUT

OPENING

CLOSING

MOTOR 2

MOTOR 1

ERD

OBD PORT

BLACK BOX

PROGRAMMING

SOLAR MODE

MOTOR

OVER

LOAD

ERD
MOTOR

OVER

LOAD

MIN

MAX

OFF

MAX

SENSE

MAX

SENSE

BATTERY

BACKUP MODE

ERD SENSITIVITY

MOTION CONTROL

OPEN

CLOSING GATE SPEED

MOTOR 2

LIMITS

MAG

LOCK

UL

ENTRAP

STOP

CLOSE

CLOSE

TIMER

MAGLOCK

DELAY

JOG

BATTERY

TEST

BATTERY

INPUT

ERROR

BATTERY

IN USE

POWER

REPLACE

BATTERY

LEAVE

CLOSED

LEAVE

OPEN

OPEN

1 TIME

BATTERY VOLTAGE

E

F

1/2

RESET

ID

PLUG

MODULE

PORT

GATE OPEN

GND

OPEN ONLY NC

OPEN ONLY 10K

PHOTO CLS NC
OPEN / CLS NC

GND

12VDC OUT

GND

GND

GND

GND

GND

JO

CL

OS

E

JO

OP

EN

TAMPER IN

TAMPER NO

GATE DISABLE

KEYPAD/CARD

GND

GND

MAX OPEN

FIRE DEPT

RADIO GND

RADIO SIGNAL

STRIKE

CLOSE COM

COM

STOP

OPEN

CLS ONLY 10K

OPEN / CLS 10K

12VDC OUT

NO

COM

NC

COM

GATE CLOSED

LIMIT 1

GND

LIMIT 2

MOTOR 1

LIMITS

MOTOR 1

MOTOR 2

LIMIT 1

GND

LIMIT 2

LIMIT 1

LIMIT 2

LIMIT 1

LIMIT 2

ID PLUG

ERROR

24VDC OUTPUT

12VDC OUTPUT

GND

GND

GND

LOOP

LOOP PWR

LOOP

CENTER

SAFETY

OFF

SINGLE

OPEN

ON/OFF

BATTERY

CLOSE

DUAL

ON

ANTI-

TAILGATE

PUSH

OPEN

PULL

OPEN

GATE

OFF

1

2

3

4

5

6

7

8

9

10

OFF

1

2

3

4

5

6

MIN

MIN

MAX

MAX

ON

OFF

2.5 sec

1.5 sec

FAULTS

OPERATOR

DSP ARM CONTROLLER

OFF

EXIT LOOP

16

MIN

16

MIN

3

1

14

12

9

7

3

1

14

12

9

7

UL SENSOR 10

K

UL SENSOR N.C.

MODE 

A

MODE B

PROGRAM

MOTOR 1

INPUTS

[

+

]

[

-

]

[

+

]

[

-

]

MOTOR 2

INPUTS

MAXIMUM CONTROLS

DSP ARM CONTROLLER

Class of operation

.....UL 325 Class I, II, III, IV

Type of gate

.....Vehicular swing gate only

Input AC power/amps

.....

Switchable: 115VAC / 6 amp, 1 phase

       

OR

     

 

230VAC / 2 amp, 1 phase

Power output

.....24 VDC

Operating temperature

.....-4°F to 158°F (-20°C to 70°C)

Cycles per hour AC input power

.....Continuous

Battery back-up cycles

.....

(7 Amp/Hr batteries fully charged).....Approx 450 cycles

Entrapment protection

.....

  - UL 325 Type A Inherent (ERD sensor)
  - Inputs for 

NORMALLY CLOSED (N.C.) or 10K 

Type

    UL 325 Type B1 (photo cell) and Type B2 (sensing edge)

   

MONITORED

 when used.

max ultra arm

Min = 39.1” (993.5 mm)

Power supply

.....24 VDC

Max Stroke length

.....21.2 in (540 mm)

Nominal thrust

.....5500 N

Maximum operating current

.....6A for max 10 sec

Max gate weight per leaf

.....1200 lbs (550 kg)

Max gate length per leaf

.....157.4 in (4 m)

Operating Temperatures

.....-20°C ~+50°C

Max = 60.3” (+/-.39“) (1531 mm (+/- 10 mm)

7.35”

186mm

5.07”

128mm

5”

127mm

8ft

12ft

16ft

18ft

Max Gate

Weight/Length

1600 lbs

725 kg

1200 lbs

544 kg

800 lbs

362 kg

600 lbs

272 kg

2

MAX Ultra Arm V1

Summary of Contents for MAX Ultra Arm

Page 1: ...ODS GATE GATE RELEASE UL 2018 THE NEW STANDARD Heavy Duty 24 Volt DC Linear Actuator for Residential Light Commercial use Super quiet With Built in limit switches Large diameter stainless steel output shaft DSP Control Optional Max App 2 Year Warranty or 100 000 Cycles whichever comes first MAX AC control box ...

Page 2: ...on against fire replace only with the same type and rating of fuse AVERTISSEMENT pour ne pas compromettre la protection contre les risques d incendie utiliser un fusible de mêmes type et caractéristiques nominales Select Input Voltage 115VAC or 230VAC AC POWER IN 115V SAFETY CENTER EXIT J3 J2 J4 J5 EXIT PWR ALARM POWER SOLAR IN BATTERY INPUT OPENING CLOSING MOTOR 2 MOTOR 1 ERD OBD PORT BLACK BOX P...

Page 3: ... function Advanced anti tailgate feature prevents unwanted intrusion Unique to Max Ultra Arm SAFETY SPECIFICA TIONS UL 325 991 compliant Class I II III and IV CSA approved Built in advanced entrapment protection and alarm output Built in gate in motion alarm for industrial applications Robust lightning protection up to 20K Volts and 10K Amps on all inputs and outputs 35 channels including loop det...

Page 4: ... for vehicles only Pedestrians must use separate entrance Sa fety Loop c l o s e o p e n JOG GATE OPEN CLOSE RESET ALARM Moving Gate Can Cause Seriou s Injury or Death CLEAR Gate may move at any time without prior warning t let children operate the gate or play gate area This entrance is for vehicles only Pedestrians must use separate entrance Sa fety Loop c l o s e o p e n JOG GATE OPEN CLOSE RES...

Page 5: ...ch Limit Switch Limit Switch Two Limits Switch System Easy mechanical release with the key Limit Cover Limit Cap MUST be ON Remove limit cap with 2 screws and slide limit cover off operator Loosen adjustment screws on limit switches and slide switches until approprate Limit LEDs lights up Tighten limit screws when finished Adjust Slow Down switches to your personal preference Cycle operator OPEN a...

Page 6: ...ic installations the two independent closing speeds can be adjusted to achieve a smooth closing sync Whichever gate closes first slow it down This enables the installer to visually sync the closing cycle This feature is unique to Maximum Control s actuators with the independent closing speeds adjusted the closing gate leaves can be synced ...

Page 7: ... that is gold zinc plated and powder coated Each AC Control Box comes with an exterior UL reset button a convenient jog key switch for emergency access or egress a 10 amp power supply with two 115 VAC accessory outlets two 7 amp batteries conveniently located behind the control panel a loop rack and much more A lockable steel cover finishes off this slick design A convenient LCD display keeps you ...

Page 8: ...ery Backup Mode Switch 2 Battery Test Switch 3 ERD Sensitivity 4 OBD Port 5 DIP Switches 6 Program Button 7 Loop Status 8 Solar Mode Application 9 Motion Control Buttons 10 Maglock Delay 11 LCD Display 12 Close Timer Switch 13 Jog Open Close 14 Closing Gate Speed 8 7 6 5 3 4 2 1 CONTROL FEA TURES AND CONNECTIONS 1 2 11 3 4 5 6 7 8 9 12 10 14 13 8 ...

Page 9: ... STAR Solar Regulator 24V 10A MORNING STAR 24V Solar Panel Output 36 V Max Open Circuit Wire solar panel terminals to solar regulator input Caution polarity matters MAX ACTUATOR CONTROL B Solar Application Guide W LOAD BATTERY SOLAR Solar Regulator Terminal NOTE Cover solar panel from sunlight BEFORE wiring to prevent a shock from occurring NOTE For more information about solar panel wiring see yo...

Page 10: ...xit RTE port Each port has indicator LEDs for troubleshooting Rotary switch to select device ID of keypad Max Cell Hub provides cell connectivity to all Max PRO series pad mt operators and MAX linear actuators for app control AT T or Verizon cell data service To activate a sim card on our portal simply choose data plan and credit card info Has RS485 comm port supports up to16 MAX Keypads card read...

Page 11: ...ion mismatch e Damages due to vandalism Section III RMA Shipping Policy a Maximum Controls LLC will pay for return shipping via standard ground UPS or USPS FOB CA on all RMA s within one year of Distributor s purchase b Any form of Expedited Shipping on any RMA will be paid by Distributor Section IV Product Returns a Products must be in original resalable condition with all warranty information ma...

Page 12: ...ra Arm protects all peripheral inputs loop inputs power inputs relay outputs and all communication lines over 35 channels of protection in 1 1 000 000 000 of a second With special emphasis on power supply protection the Max Ultra Arm is guaranteed to withstand any lightning hit more than 50 feet away Truly protected like no other operator in the world ...

Page 13: ...C 949 699 0220 10530 Lawson River Ave Fountain Valley CA 92708 USA Independent Dealer or Distributor Maximum Controls LLC 949 699 0220 10530 Lawson River Ave Fountain Valley CA 92708 USA Independent Dealer or Distributor www Max US com ...