MAX32600 User’s Guide
Analog Front End
8.3 ADC
Field
Bits
Default
Access
Description
data_reg
15:0
0000h
R/O
ADC Current Valid Data Sample
Direct read of the ADC output data; cleared on cpu_adc_strt and registered during adc_dv.
8.3.5.1.8
ADCCFG_CTRL1
ADCCFG_CTRL1.scan_cnt
Field
Bits
Default
Access
Description
scan_cnt
18:16
000b
R/W
Channel Scan Count
Number of channels to scan (if an ADC scanning mode is active) is given by the value of this field + 1:
• 0: Scan 1 channel
• 1: Scan 2 channels
• 2: Scan 3 channels
• 3: Scan 4 channels
• 4: Scan 5 channels
• 5: Scan 6 channels
• 6: Scan 7 channels
• 7: Scan 8 channels
8.3.5.1.9
ADCCFG_SCAN1
ADCCFG_SCAN1.adc_scan0
Field
Bits
Default
Access
Description
adc_scan0
7:0
00h
R/W
ADC Scan Configuration - Channel 0
Rev.1.3 April 2015
Maxim Integrated
Page 445