![MAXDATA PLATINUM 2200 IR User Manual Download Page 10](http://html1.mh-extra.com/html/maxdata/platinum-2200-ir/platinum-2200-ir_user-manual_1743427010.webp)
10
Setting up the System
Descriptions of the front panel LEDs are listed in the following table.
Table 2. Description of front panel LEDs
LED
Color
Condition Description
Power LED
Green
ON
Power on
OFF
Off
Status
Green
ON
System ready
Green
BLINK
System ready, but degraded: redundancy lost such as PS
or fan failure; one of several DIMMs not ready; non-critical
temperature/voltage threshold
Amber
BLINK
Non-critical failure: critical temperature/voltage threshold;
minimum number fans not present or failed; voltage
regulator overheated
Amber
ON
Critical alarm: CPU 1 missing or failure; voltage fault; no
memory present; BMC/video memory failure
OFF
AC power off; powered down (DC-off state or S5), and no
degraded, non-critical, critical conditions exist*
HDD activity
Green
BLINK
Hard drive activity
NIC activity
Green
ON
Linked
Green
BLINK
LAN activity
OFF
Idle
ID LED
Blue
BLINK
Server identification; toggled by ID button or software
OFF
Server identification; toggled by ID button or software
* When the server is powered down (transitions to the DC-off state or S5), the BMC is still on
standby power and retains the sensor and front panel status LED state established before the
power-down event. If the system status is normal when the system is powered down (the
LED is in a solid green state), the system status LED will be off.